DIUTHAME
1 / 12Páginas

{{requestButtons}}

Excertos do catálogo

DIUTHAME - 1

Ionization-assisting substrates Desorption Ionization Using Through Hole Alumina MEmbrane

Abrir o catálogo na página 1
DIUTHAME - 2

DIUTHAME® ensures high reproducibility and accuracy in your mass spectrometry tasks! DIUTHAME is … … an ionization-assisting tool developed by Hamamatsu for MALDI TOF-MS (time-of-flight mass spectrometry). DIUTHAME streamlines the ionization process in mass spectrometry by replacing the matrix used in MALDI, and totally eliminates the cumbersome pretreatment of samples needed up till now. Medical care Drug discovery Basic research Material science Places where DIUTHAME is used Examples of compatible samples Research institutes with MALDI mass spectrometers Compatible with a wide range of...

Abrir o catálogo na página 2
DIUTHAME - 3

No matrix background noise High reproducibility (Measureble at low molecular region) with minimal variation no matter who does High spatial resolution Needs no sample pretreatment, slashes the time and effort nanometer-order structure Measurement using matrix How DIUTHAME differs from matrix ionization Matrix preparation / Apply matrix Measurement using DIUTHAME DIUTHAME is placed on sample *In mass spectrometry imaging Generates matrix-derived noise Background noise (Low molecular region) Generates virtually no noise Depends on worker skill Spatial resolution High resolution due to...

Abrir o catálogo na página 3
DIUTHAME - 4

Mass spectrum measurement examples Amino acid/Peptide mix Measurements were carried out in cooperation with Associate Professor Yasuhide Naito, The Graduate School for the Creation of New Photonics Industries Amino acid Amino acid Alanine A Cysteine C Histidine H Arginine R Tryptophan W W[M+Na]+ C[M+K]+ Measurement sample details Measurement method 1The mixed sample was dropped 1 μL from above the DIUTHAME. Dissolve 5 amino acids in pure water and mix them. ▼ Measurement condition Measuremenr sample Mixture of 5 kinds of amino acids 2Remove the film and attach the DIUTHAME substrate onto the...

Abrir o catálogo na página 4
DIUTHAME - 5

Mass spectrum measurement examples Polyethylene glycol 2000 / Polystyrene / Insulin Polyethylene glycol 2000 Measurement method 1The mixed sample was dropped 3 μL from above the DIUTHAME. 2Remove the film and attach the DIUTHAME substrate onto the measurement plate. Measurement sample details 1×104 PEG2000(1 mg/mL in ACE): NaTFA(1 mg/mL in ACE)=10: 1 ACE: Acetone 0.5×104 ▼ Measurement condition Measuremenr sample Reflectron, positive ion mode Measurement method 1The mixed sample was dropped 3 μL from above the DIUTHAME. 2Remove the film and attach the DIUTHAME substrate onto the measurement...

Abrir o catálogo na página 5
DIUTHAME - 6

Mass spectrometry imaging measurement examples Black rice Measurements were carried out in cooperation with Designated Assistant Professor Keiko Kuwata, The Institute of Transformative Bio-Molecules Nagoya University Measurement method Set a slice of black rice on an ITO glass slide. Remove the film and place the DIUTHAME on the black rice. Drop 2 μL of “70 % AcCN / 30 % H20” solution from above the DIUTHAME to extract the components of interest. Start measurement after the sample dries. Measurement example Sample Mass spectrometry imaging of black rice * * After taking mass spectrometry...

Abrir o catálogo na página 6
DIUTHAME - 7

Mass spectrometry imaging measurement examples MOuse brain Measurement method Set a slice of frozen mouse brain on an ITO glass slide. Place DIUTHAME on the mouse brain slice before it thaws. After the sample thaws with fingertip heat the components of the sample will soak up to the surface by capillary action. Start measurement after the sample dries. Slice Sample Heat Do this work in a cryostat MS imaging result of one sample taken by positive and negative ion mode Laser irradiation marks on the DIUTHAME * Before making measurements using mass spectrometer, an optical image was captured...

Abrir o catálogo na página 7
DIUTHAME - 8

Measurement example of mass spectrometry imaging using blotting Strawberry Measurement carried in cooperation with Associate Professor Hirofumi Enomoto, The Department of Biosciences Teikyo University Measurement method ▼Image of strawberry ▼Blotting image ▼Optical image Cut an unfrozen Place the DIUTHAME, Allow the DIUTHAME Start measurement after the sample strawberry in half. with its rear side facing to soak up the the cut surface of the strawberry's drie d ies. dries. strawberry to allow w blotting. components. Measurement example 1 e Number Positive ion mode measure ion mode...

Abrir o catálogo na página 8
DIUTHAME - 9

Measurement example of mass spectrometry imaging using blotting Industrial product Measurement method Place the DIUTHAME on the measurement position (where white stains have occurred) of the product. Drop 1 μL of solvent from above the DIUTHAME to transfer the stains. Set the DIUTHAME with the transferred stains on the measurement plate. Start measurement after the sample dries. Measurement example White stains have occurred on an industrial product. Measurement of a large, thick sample using blotting technique ▼ Measurement condition Laser pitch * Area in white dotted line circle shows...

Abrir o catálogo na página 9
DIUTHAME - 10

Dimensional outline For Mass spectrum ● 3 × 9 ch type · A14111-3-1 (For mass spectrum) 27.0 ± 0.2 ADHESIVE SECTION *1 *1 Adhesive section with target plate or ITO glass slide *2 Thickness including conductive tape REAR VIEW

Abrir o catálogo na página 10
DIUTHAME - 11

Dimensional outline For MS imaging ● 18 type · A13331-18-2 · A13331-18-2B (For blotting) EFFECTIVE AREA 1 MIN. (5.5) ●Glass slide size type · A13331-5019-1 · A13331-5019-1B (For blotting)

Abrir o catálogo na página 11
DIUTHAME - 12

Website information To find more detailed information about DIUTHAME, please visit our website via QR code or URL below. [Main contents on website] • Application notes • How-to-use instruction video • Related literature • What the developer has to say • Interview with users https://www.hamamatsu.com/jp/en/product/optical-components/DIUTHAME/index.html * DIUTHAME is registerd trademarks of HAMAMATSU PHOTONICS K.K.. Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office. Information...

Abrir o catálogo na página 12

Todos os catálogos e folhetos técnicos HAMAMATSU

  1. FLAT PANEL TYPE

    4 Páginas

  2. SPAD MODULES

    5 Páginas

  3. LIGHTNINGCURE

    29 Páginas

  4. Xenon Flash Lamps

    19 Páginas

  5. NanoZommer series

    8 Páginas

  6. C13410 series

    4 Páginas

  7. C13410-06A

    4 Páginas

  8. PMA-12

    8 Páginas

  9. L12542

    4 Páginas

  10. FLAT EXCIMER

    16 Páginas

  11. L15208-01

    3 Páginas

  12. L15856-01

    3 Páginas

  13. L14001-01

    2 Páginas

  14. L11854-336-05

    2 Páginas

  15. L14351-02

    4 Páginas

  16. GC-113A

    2 Páginas

  17. IMAGEMX2 series

    8 Páginas

  18. ORCA-Fusion BT

    9 Páginas

  19. J12853

    2 Páginas

  20. J12432-01

    2 Páginas

  21. J10919 SERIES

    2 Páginas

  22. C15780-401

    4 Páginas

  23. H15460-40

    4 Páginas

  24. R14755U-100

    2 Páginas

  25. Si APD S14124-20

    3 Páginas

  26. C13398 series

    5 Páginas

  27. Si APD S14643-02

    6 Páginas

  28. LIGHT SOURCES

    23 Páginas

  29. PHOTOTUBES

    8 Páginas

  30. PSD

    8 Páginas

  31. InGaAs Photodiodes

    20 Páginas

  32. Infrared Detectors

    36 Páginas

  33. Photo IC

    8 Páginas

  34. Image Sensors

    48 Páginas

  35. Si Photodiodes

    48 Páginas

  36. Si APD

    16 Páginas

  37. Photonic Devices

    44 Páginas

  38. IMAGE INTENSIFIERS

    20 Páginas

  39. FLOW CELLS

    4 Páginas

  40. SCANBLOCK C10516

    4 Páginas

  41. UV TRONR DRIVING

    2 Páginas

  42. High sensitivity

    2 Páginas

  43. Si photodiodes

    41 Páginas

Catálogos arquivados