DIGITAL CAMERA ORCA-Flash4.0 V2 for lifescience
1 / 8Páginas

{{requestButtons}}

Excertos do catálogo

DIGITAL CAMERA ORCA-Flash4.0 V2 for lifescience - 1

DIGITAL CAMERA A game changer from inc^ptiooj^icl a joroven performer since its initial release, the ORCA-Flash4.0 V2 offers unrivaled flexibility across a wide range of imaging applications. Easily change from USB to Camera Link connectivity. Switch from a blazing fast scan to a virtually noiseless slow scan by a simple click ij^oftware. Use our Lightsheet Readout Mode™ fair seamless integration with light sheermicroscopy systems. Robust triggering allows the ORCA-Flash4.0 V2 to drive other devices or be driven by them. And then there's the highest QE of any sCMOS camera on the market. Exceptional quantum efficiency electrons median Standard scan electrons median | camera Link] at 4.0 megapixels

Abrir o catálogo na página 1
DIGITAL CAMERA ORCA-Flash4.0 V2 for lifescience - 2

What's New in the ORCA-Flash4.0 V2 Two Scan Speeds While the read noise at standard scan is only 1.9 electrons rms (1.3 electrons median), there are some experiments for which even lower noise is more important than raw speed. New in the ORCA-Flash4.0 V2 is an additional slow scan readout mode with read noise of just 1.5 electrons rms (0.9 electrons median). Both the USB and Camera Link configurations of the camera have this low noise capability. Lightsheet Readout ModeTM To enable the best speeds and synchronization for light sheet microscopy, the ORCA-Flash4.0 V2 configured with the...

Abrir o catálogo na página 2
DIGITAL CAMERA ORCA-Flash4.0 V2 for lifescience - 3

Readout noise distribution Read noise: rms or median? RMS and median are both valid statistical models for evaluating the central tendencies of data distributions, such as pixel noise. With CCDs there are never any issues regarding which model to use o because the typical read noise for all pixels is very similar; thus rms and median are equivalent. With sCMOS, the structure of the sensor inherently has more pixel variation and the extreme low noise of the sensor makes variation more statistically significant. But when it comes to evaluating camera performance, the truly meaningful spec is...

Abrir o catálogo na página 3
DIGITAL CAMERA ORCA-Flash4.0 V2 for lifescience - 4

High sensitivity means extreme versatility The ORCA-Flash4.0 V2 is changing the game of scientific imaging. For years, cooled CCDs have been the go-to technology for fluorescence applications such as GFP or multi-channel imaging that require high signal to noise, high contrast images. EM-CCDs have been scientists' choice for low-light, often high speed applications such as TIRF or spinning disk confocal. For lack of a better choice, the same technology has been adopted for localization microscopy. The ORCA-Flash4.0 V2 offers such a multitude of benefits that it not only easily accomplishes...

Abrir o catálogo na página 4
DIGITAL CAMERA ORCA-Flash4.0 V2 for lifescience - 5

ORCA-Flash4.0 V2 Conduct your research ImageConductor connectivity TM Every ORCA-Flash4.0 V2 includes ImageConductor connectivity™ so that it’s enabled for both USB 3.0 (default) and high speed Camera Link. If your imaging tempo is 30 frames/s, then the default configuration with USB 3.0 is right for you. If you need something a little more lively… presto, just add a Camera Link board now or later to achieve 100 frames/s of full 4-megapixel images. Both 30 frames/s USB 3.0 100 frames/s Camera Link options deliver the same low noise, high quantum efficiency imaging for unprecedented...

Abrir o catálogo na página 5
DIGITAL CAMERA ORCA-Flash4.0 V2 for lifescience - 6

Up to 40 min. of continuous full speed, full resolution acquisition*1 *1 This was tested with Dell T5500 (E5640 2.66GHz) + RAIDO (LSI MegaRAID SAS 9260-4i) and 4 pes SATA SSD drives (SAMSUNG MZ-7PC512) Windows7 64 bit Allegro or presto? You be the Conductor. When conducting imaging with a camera that has 4 194 304 pixels with 16-bit data depth, a single image is 8 megabytes. But capturing a single frame is child's play. What really matters is sustained, sequential image capture. Hamamatsu's ImageConductor gives you control over which speed works for you. In the default configuration, the...

Abrir o catálogo na página 6
DIGITAL CAMERA ORCA-Flash4.0 V2 for lifescience - 7

*2 Full well capacity / Readout noise median in slow scan *3 Minimum exposure time in internal trigger mode varies depending on sub-array setting. Minimum exposure time is in standard scan

Abrir o catálogo na página 7
DIGITAL CAMERA ORCA-Flash4.0 V2 for lifescience - 8

ORCA-Flash4.0 V2 Dimensional outlines Camera head (approx. 2.0 kg) Unit: mm C-Mount 85.5 13.5 125 85 Configuration example C-mount TV camera adapter Relay lens (0.5×, etc.) ORCA-Flash4.0 V2 digital camera set ORCA-Flash4.0 V2 HCImage*4 HSR*4 AC adapter Standard Commercially available software Option S SD C-mount lens USB 3.0 interface board and cable PC Laptop PC Camera Link interface board and cable *4 HCImage/HSR software provides standard image measurement functions. Please contact your local Hamamatsu Sales Office or distributor regarding actual configuration. Cover image: Rat...

Abrir o catálogo na página 8

Todos os catálogos e folhetos técnicos HAMAMATSU

  1. FLAT PANEL TYPE

    4 Páginas

  2. SPAD MODULES

    5 Páginas

  3. LIGHTNINGCURE

    29 Páginas

  4. Xenon Flash Lamps

    19 Páginas

  5. NanoZommer series

    8 Páginas

  6. C13410 series

    4 Páginas

  7. C13410-06A

    4 Páginas

  8. PMA-12

    8 Páginas

  9. L12542

    4 Páginas

  10. FLAT EXCIMER

    16 Páginas

  11. L15208-01

    3 Páginas

  12. L15856-01

    3 Páginas

  13. L14001-01

    2 Páginas

  14. L11854-336-05

    2 Páginas

  15. L14351-02

    4 Páginas

  16. GC-113A

    2 Páginas

  17. IMAGEMX2 series

    8 Páginas

  18. ORCA-Fusion BT

    9 Páginas

  19. DIUTHAME

    12 Páginas

  20. J12853

    2 Páginas

  21. J12432-01

    2 Páginas

  22. J10919 SERIES

    2 Páginas

  23. C15780-401

    4 Páginas

  24. H15460-40

    4 Páginas

  25. R14755U-100

    2 Páginas

  26. Si APD S14124-20

    3 Páginas

  27. C13398 series

    5 Páginas

  28. Si APD S14643-02

    6 Páginas

  29. LIGHT SOURCES

    23 Páginas

  30. PHOTOTUBES

    8 Páginas

  31. PSD

    8 Páginas

  32. InGaAs Photodiodes

    20 Páginas

  33. Infrared Detectors

    36 Páginas

  34. Photo IC

    8 Páginas

  35. Image Sensors

    48 Páginas

  36. Si Photodiodes

    48 Páginas

  37. Si APD

    16 Páginas

  38. Photonic Devices

    44 Páginas

  39. IMAGE INTENSIFIERS

    20 Páginas

  40. FLOW CELLS

    4 Páginas

  41. SCANBLOCK C10516

    4 Páginas

  42. UV TRONR DRIVING

    2 Páginas

  43. High sensitivity

    2 Páginas

  44. Si photodiodes

    41 Páginas

Catálogos arquivados