Excertos do catálogo

PSW 31x-8 (with hollow shaft) 4.5 viewing window and access to address switch and status display Data interfaces CANopen, PROFIBUS DP DeviceNet, Modbus RTU, Sercos, , EtherCAT, PROFINET, EtherNet / IP POWERLINK, IO-Link , 20 % (basis time 600 s) Positioning range Shock resistance Vibration resistance Output shaft 8 mm solid shaft or 8 mm hollow shaft with adjustable collar absolute measurement of position taken directly at the output shaft in accordance with IEC / DIN EN 60068-2-27 in accordance with IEC / DIN EN 60068-2-6 not subject to mechanical limits Maximum radial force Ambient temperature Storage temperature Protection class viewing window and access to address switch and status display 7 stainless steel PSW 31x-8-V (with solid shaft) IP 68 at standstill 1), IP 66 during 1) rotation (tested with water) Maximum axial force Positioning accuracy Power consumption (control unit) torque support welded V2A housing, output shaft sealed with quad-ring The order key and accessories can be found on p. 18 / 19. Nominal current 24 V DC ± 10 % galvanically separated between control and motor and bus hollow shaft ø 8H9 / 20 depth Supply voltage Duty cycle Dimensions in mm. For details of the connections please see also p. 55 and the instruction manual. Data sheet PSW 31x-8 – Date: 08/ 2021 – Subject to technical changes without no
Abrir o catálogo na página 1
ORDER KEY PSE / PSS / PSW 3 SERIES A CA: CANopen Positioning System Efficient (see p.22 - 28) Positioning System Stainless (see p.29 - 33) Positioning System Washable (see p.34 - 38) not for PSE 31x always via an extra connector plug, not for IO-Link or PSW 5) not for PSE 34xx 3) 4) 0: CE N: NRTL + CE S: STO + CE without test pulses 7) 0: without M: with 6) Z: Plug-in, Y-coded, with jog keys 3) 5) T: TO + CE with S test pulses 7) Y: TO + NRTL S without test pulses 7) Z: TO + NRTL S with test pulses 7) 6) only 14 mm output shafts only for IP 65, not for PSE 34xx, only for EtherCAT,...
Abrir o catálogo na página 2
ACCESSORIES PSE / PSS / PSW 3 SERIES The connectors shown here can be used for all 3 types of device (PSE / PSS / PSW). This ensures that the PSE (IP 54) and PSS (IP 65) comply with the IP protection classes. We will also be pleased to help you find a suitable mating connector for the PSW (IP 68) if necessary – just ask us! Power supply + databus connector (2x) (for option 0) 1) Power supply + databus (2x) + jog key connector (for option T, not for PSW) 1) 2) Cable and connectors for 1-connector solution 3) (for option Y or IO-Link) 1) CANopen 4) PROFIBUS DP Modbus RTU 5 m: Order no....
Abrir o catálogo na página 3Todos os catálogos e folhetos técnicos Halstrup-walcher GmbH
-
HIPERDRIVE HDA 70
2 Páginas
-
Data sheet direvt drive PSD 49
2 Páginas
-
Data sheet digital manometer EMA 84
1 Páginas
-
Data sheet digital manometer EMA 200
1 Páginas
-
Data sheet direvt drive PSD 41
2 Páginas
-
Data sheet direct drive PSD 42
2 Páginas
-
Data sheet direct drive PSD 40
2 Páginas
-
Data sheet direct drive PSD 43
2 Páginas
-
Data sheet direct drive PSD 48
2 Páginas
-
Data sheet HDA 70
2 Páginas
-
Flow rate calibrations
4 Páginas
-
Data sheet display panel PUC 44
2 Páginas
Catálogos arquivados
-
Drive technology catalog
36 Páginas