Excertos do catálogo

Dry blocks for heating and cooling Dry block heating/cooling systems » PCH-1, PCH-2 and PCH-3 Dry block heating/cooling systems PCH-1, PCH-2 and PCH-3 Compact, flexible, easy to use systems for rapid heating and cooling of microtubes; very effective tools for DNA/RNA sample preparation techniques. Ⅲ Cooling/heating setting range from -10°C to 100°C, with very rapid cool down and heat-up times Ⅲ Stability ±0.1°C Ⅲ Choice of three models: capacity for up to 32 year warranty microtubes in a combination of two sizes (PCH-1) or up to 20 microtubes of one size (PCH-2 and PCH-3) Ⅲ Convenient integral reaction timer with audible alarm Model PCH-1 shown Ingenious block construction, combined with powerful Peltier cooler, produces very rapid heating and cooling Dry temperature control system maintains clean and aerosol-free environment 2-line LCD display clearly indicates both set and actual values for temperature and time Simple push button combinations for easy set-up PCH-1 Block holds a combination of two microtube sizes simultaneously – up to a total of 32 tubes: 12 x 1.5 ml plus 20 x 0.5 ml PCH-2 up to a total of 20 x 1.5 ml mictrotubes PCH-3 up to a total of 20 x 2 ml microtubes Rapid DNA denaturation at 95°C quickly achieved DNA denaturation techniques further supported with an audible alarm for denaturation ‘time-up’; samples can then be quickly cooled Ⅲ Life-science - storing restriction enzymes, nick translations, ligation reactions, restriction digests, protein solubilisation for PAGE, warm incubation of microcentrifuge tubes for hybridisation, enzyme reactions and deactivations Ⅲ Clinical - cooling blood samples prior to coagulation testing © Grant Instruments (Cambridge) Ltd
Abrir o catálogo na página 1
PCH dry block heating/cooling systems – models and specifications PCH-1 PCH-2 h: 165 mm d: 260 mm w: 240 mm weight: 3.6 kg Block dimensions Temperature control range Setting resolution Temperature setting range Dry blocks for heating and cooling Dry block heating/cooling systems » PCH-1, PCH-2 and PCH-3 » Models and specifications Temperature display Heat up time 25°C to 100°C °C/min Cool down time Input voltage Input current Power supply © Grant Instruments (Cambridge) Ltd » Dry block heating/cooling systems
Abrir o catálogo na página 2Todos os catálogos e folhetos técnicos Grant Instruments
-
Squirrel sq loggers
8 Páginas
-
MMS-3000 Magnetic Stirrer
2 Páginas
-
PV-1 Vortex Mixer
3 Páginas
-
V-32 Vortex Mixer
3 Páginas
-
PMS-1000i Microplate Shaker
2 Páginas
-
PSU-10i Orbital Shaking Platform
3 Páginas
-
PTR-25 360° Vertical Mini Rotator
3 Páginas
-
TXF200 heated circulating baths
4 Páginas
-
LTC4 Refrigerated Circulating Baths
9 Páginas
-
TC120 heated circulating baths
4 Páginas
-
BTD Dry Block Heating System
2 Páginas
-
QB series dry block heating systems
4 Páginas
-
LTC2 Refrigerated Circulating Baths
9 Páginas
-
Heated circulators
4 Páginas
-
T100 heated circulating baths
4 Páginas
-
LSB Aqua Pro
4 Páginas
-
OLS Aqua Pro
4 Páginas
-
JB Academy
2 Páginas
-
JB Nova
2 Páginas
-
SUB Aqua Pro
2 Páginas
-
General Information
3 Páginas
-
Grant Data Loggers
3 Páginas
-
OEM and Private Label Projects
2 Páginas
-
Cryopreservation
4 Páginas
-
MOD Heat Transfer Apparatus
3 Páginas
-
Transportable Incubator
2 Páginas
-
Inspissator
3 Páginas
-
Temperature Gradient Plate
4 Páginas
-
PCR UV Cabinets
6 Páginas
-
Aspirator
3 Páginas
-
Densitometers
3 Páginas
-
Dry Blocks For Heating and Cooling
7 Páginas
-
Centrifuges
10 Páginas
-
Orbital Shaker-Incubators
4 Páginas
-
Shakers, Mixers and Stirrers
14 Páginas
-
Rockers and Rotators
11 Páginas
-
Dry Block Heaters
9 Páginas
-
Ultrasonic Baths
5 Páginas
-
Shaking Water Baths
6 Páginas
-
Unstirred Water Baths
11 Páginas
-
Flow Heater
3 Páginas
-
Labwise Software
3 Páginas
-
Refrigerated Circulating Baths
9 Páginas
-
Heated Circulating Baths
14 Páginas
-
Scientific catalogue
158 Páginas
-
Data Acquisition Catalogue
43 Páginas