Excertos do catálogo

Reason DR60 Digital Recorder and PMU The Reason DR60 is a centralized one-box multifunctional digital fault recorder (DFR). The small form factor, together with the ruggedness of design drawn from field experience in yard-mounted applications, ensures that the Reason DR60 can be installed in harsh utility and industrial environments. The high scalability in binary I/O counts along with modern communications such as IEC61850 Edition 2 and synchronization protocols such as MMS, GOOSE and PTP precision-timing, place the DR60 at the forefront of digital fault recording technology. Full system awareness The DR60 outstanding performance, high accuracy and complete set of functionalities provide data for several applications and analysis, such as: • Network faults • Performance of the protective IEDs • Dynamic response of the network • Long-term trends • Revenue readings • Asset Management Situational Awareness • Waveform recorder supporting 256 disturbance recorder • Trend Recorder & sequence of events recorder • PMU IEEE C37.118.1/2-2011/1a-2014 High Density I/O • Up to 32 analog inputs • Up to 96 binary inputs and up to 48 binary outputs • Up to 32 high-speed transducer inputs for HVDC applications Born with IEC 61850 spirit, this is the DR60 motto. That means all its internal functions are implemented and mapped according to IEC 61850 ed.2 logical nodes and data models. Even its configuration is performed using native SCL files. It features MMS report control blocks for communication with supervisory systems and GOOSE publisher and subscriber for interaction with other IEDs though the IEC 61850 process bus. • Supporting industry standard Substation Protocols and Standards The DR60 Digital Recorder offers what is best for high-quality measurements, synchronization, communication and security. To do so, the DR60 utilizes well-recognized protocols for time synchronization and communication, such as: IEEE1588v2, MMS and GOOSE. The DR60 is full compliant with NERC CIP-5 and integration with Internet of Things (IoT) through Predix applications are scheduled for future firmware releases. Ready for today’s and tomorrow’s substations The DR60 is a modern and flexible solution that meets current and future application requirements granting the best that the IEC61850 has to offer to the customer’s installations. protocols including DNP3, MMS and GOOSE • Time synchronization including support for IEEE 1588 PTPv2 and IRIGB • Serial (RS232 and Ethernet (RJ45 or LC) interfaces Application Flexibility • Cross triggering • Trigger matrix for easy output configuration and special logic schemes • Native configuration in SCL format • MMS report cont
Abrir o catálogo na página 1
Phasor Measurement Unit (PMU) The DR60 provides powerful and cost-effective synchrophasor measurement solution according according to IEEE C37.118.1/22011/1a-2014 standard and is capable of transmitting its data in up to 4 separate data streams. Each stream can be configurable independently based on: contents; frame rate; Class of service (P or M) and communication mode (TCP or UDP). DR60 architecture example: DFR-Monitoring-PMU Ethernet ports Type Use Configuration, monitoring, Comms Fiber type Emission power Maximum applicable power Isolation Level DR60 architecture example: Extension I/O...
Abrir o catálogo na página 2
Binary inputs specifications IN SERVICE contact specifications Level High Acquisition sampling rate Binary outputs Making Capacity Breaking Capacity Dropout time Maximum voltage Permissible current continuous Dry contact relay, normally closed Switching Voltage Withstand voltages across open contacts Permissible short time value for 1s Nominal Voltage Dry contact relay, normally open Switching Voltage Voltage inputs specifications (50/60 Hz) Maximum continuous current Standard input High Accuracy Inputs Maximum voltage Making Capacity Breaking Capacity Analog Input Accuracy Operation time...
Abrir o catálogo na página 3
Radiated emission above 1GHz Class A 1 GHz to 3 GHz 56 dB(µV/m) Average 76 dB (µV/m) peak at 3m 3 GHz to 6 GHz 60 dB(µV/m) Average 80 dB (µV/m) peak at 3m EMC tests according to IEC 60255-26 IEC 61000-4-2:2008 (Electrostatic discharge) IEC 61000-4-4:2012 (Fast transient disturbance) Zone A Differential mode: 2 kV Common mode: 4 kV IEC 61000-4-8:2009 (Power magnetic immunity) IEC 61000-4-11:2004 IEC 61000-4-29:2000 (Voltage dip, short interruptions and voltage variation immunity tests) - AC and DC voltage dips Test level: 0% residual voltage Duration time a.c.: 1 cycle | d.c.: 16.6ms - Test...
Abrir o catálogo na página 4Todos os catálogos e folhetos técnicos GE Grid Solutions
-
Static Var Compensator Solutions
12 Páginas
-
Synchronous Condenser Systems
8 Páginas
-
High Voltage Direct Current Systems
12 Páginas
-
Kelman TRANSFIX
2 Páginas
-
Kelman MINITRANS
2 Páginas
-
MIG
3 Páginas
-
DTR
4 Páginas
-
SPM
8 Páginas
-
TOV
3 Páginas
-
MDS SD Series
4 Páginas
-
MIC
2 Páginas
-
Multilin F60
9 Páginas
-
Model PT7-1-150 & PT7-1-200
2 Páginas
-
Models PT7-2-150 & PT7-2-200
2 Páginas
-
Model PT6-2-125
2 Páginas
-
Model PT6-1-125
2 Páginas
-
Models PTW5-1-110&PTW5-2-110
2 Páginas
-
Models PTG5-1-110 & PTG5-2-110
2 Páginas
-
Models PTG4-1-75 & PTG4-2-75
2 Páginas
-
Models PTW3-1-60 & PTW3-2-60
2 Páginas
-
Models PTG3-1-60 & PTG3-2-60
2 Páginas
-
Models PT3-1-45 & PT3-2-45
2 Páginas
-
Model 3PT3-60
2 Páginas
-
MIG II
8 Páginas
-
Model JVW-110C
2 Páginas
-
Model JVW-5AC-1
2 Páginas
-
Model JVW-5C
2 Páginas
-
Multilin T60
9 Páginas
-
Multilin 489
9 Páginas
-
Multilin™ D25
8 Páginas
-
Multilin D485
1 Páginas
-
Multilin P485
1 Páginas
-
MultiNet
3 Páginas
-
iNET-II
4 Páginas
-
MDS™ iNET 300
2 Páginas
-
MDS iNET 900®
2 Páginas
-
Multilin™ PQM II
8 Páginas
-
Multilin L90
10 Páginas
-
COSI
2 Páginas
-
Multilin 850
4 Páginas
-
G650
8 Páginas
-
HV Compensation & Filtering Products
20 Páginas
-
Hydran M2
2 Páginas
-
MultiLink ML3000 Series
12 Páginas
-
TN1U
4 Páginas
-
JungleMUX SONET Multiplexer
4 Páginas
-
Multilin™ MM200
8 Páginas
-
Multilin™ MM300
8 Páginas
-
Multilin 339
16 Páginas
-
Multilin 469
10 Páginas
-
Multilin A60
6 Páginas
-
Multilin 350
16 Páginas
-
Multilin F650
12 Páginas
-
Multilin 750/760
10 Páginas
-
F35
8 Páginas
-
345
12 Páginas
-
745
8 Páginas
-
Multilin G30
9 Páginas
-
Transmission Overview
9 Páginas
-
Air-Core Reactors
8 Páginas
-
Multilin HardFiber System
14 Páginas
-
Multilin UR & URPlus
18 Páginas
-
Multilin C30
6 Páginas
-
Voltage Regulators
16 Páginas
-
g3 Technology
2 Páginas
-
Rectifier
4 Páginas
-
RMIO
2 Páginas
-
MiCOM Agile P54A/B
2 Páginas
-
MultiSync™ 100
6 Páginas
-
Multilin G60
9 Páginas
-
Multilin D400
12 Páginas
-
GL 107X
2 Páginas
-
Disconnectors
12 Páginas
-
CGVB-05
2 Páginas
-
KOTEF
4 Páginas
-
Adjustable Height Sub Base
2 Páginas
-
HV Transmission Solutions
8 Páginas
-
FK
4 Páginas
-
B65
4 Páginas
-
Safe-NET Network Transformer
8 Páginas
-
Green Power Transformers
4 Páginas
-
Transformer solutions across the grid
24 Páginas
-
COSI-RogoFlex
2 Páginas
-
Grid-GA-L3-COSI_CEVT
2 Páginas
-
P50 Agile P154 / P253
4 Páginas
-
MiCOM Agile P24x
8 Páginas
-
269 Plus Motor Protection System
8 Páginas
-
239 Motor Protection
8 Páginas
-
Transformers Three Phase up to 1500MVA
12 Páginas
-
Dead Tank Circuit Breakers Brochure
20 Páginas
-
Power Transformers
8 Páginas
-
smorb
3 Páginas
-
MIF II
8 Páginas
-
SR family
2 Páginas
-
735/737
4 Páginas
-
hid
2 Páginas
-
dtp
5 Páginas
-
IEC Oil Filled & SF
12 Páginas
-
Gas Insulated Switchgear
24 Páginas
-
Multilin UR & UR Plus
18 Páginas
-
M60
8 Páginas
-
Live Tank Circuit Breakers Brochure
20 Páginas
-
MDS Orbit Platform Brochure
12 Páginas
-
Digital Energy Mining Brochure
2 Páginas