MultiSync™ 100
1 / 6Páginas

{{requestButtons}}

Excertos do catálogo

MultiSync™ 100 - 1

MultiSync™ 100 Modernize time synchronization for power systems Precise Time Accurate time synchronization is required to coordinate the actions of protective relays, generator controllers, distributed resources, power system controllers, energy storage, and microgrids. Every device must be synchronized to the same time source to ensure coordinated action. Traditional time synchronization methods have shortcomings, such as the separate analog copper wiring required for IRIG-B or the lower accuracy of SNTP/NTP over Ethernet networks. Synchronization • Supports IEEE 1588-2008 and C37.238-2011 for power system applications • Operates as a master clock or ordinary clock The MultiSync 100 uses the IEEE® Standard 1588-2008 for Precision Clock Synchronization Protocols used in Networked Measurement and Control Systems, as well as the C37.238-2011 IEEE Standard Profile used in Precision Time Protocols within Power System Applications. As a result, the MultiSync 100 provides highly accurate time synchronization, and allows for the gradual retirement of less accurate or more costly methods. • Part of complete GE end-to-end timing solution for protection and control • Integrates into existing time synchronization networks by supporting traditional time synchronizing methods Key Benefits • Supports latest 1588-2008 and C37.238-2011 standards for Ethernet-based time synchronization • Upgrade existing substations to 1588 support without replacing existing time synchronization infrastructure • Provides accurate time synchronization for protection and control applications through MultiLink™ Ethernet switches, Multilin™ Universal Relays and Multilin 8 Series Relays • Designed and tested specifically for rugged environments such as utility substations Supports Common Methods • IEEE 1588-2008 / C37.238-2011 • NTP/SNTP • IRIG-B • Modified Manchester Applications • Power substations for synchrophasor and grid modernization applications • IEC® 61850 process bus sampled value applications • Industrial Ethernet for time-based control • Upgrading legacy installations to IEEE 1588 • DCF77 • TTL Flexible Design • Compact size and DIN rail mountable case for easy mounting • Tested to substation environmental standards • Wide range, Isolated power supply

Abrir o catálogo na página 1
MultiSync™ 100 - 2

The need for cost-effective, accurate time synchronization Upgrade to IEEE 1588 at low cost Accurate time synchronization is becoming a critical requirement in today’s power system substations. For example: • Synchrophasor measurements to support wide area monitoring systems and remedial action schemes require time synchronization accurate down to 1 microsecond • Merging units, that publish sampled values for use by protective relays, meters, and control devices require time synchronization accuracy of 25 microseconds • Coordinating fault records and event logs across multiple devices...

Abrir o catálogo na página 2
MultiSync™ 100 - 3

A complete end-to-end solution for IEEE 1588 The MultiSync 100 clock is a 1588 GrandMaster clock that can be synchronized to a GPS satellite, and also an ordinary clock synchronized to a local or system wide 1588 GrandMaster clock. The operating mode is determined by the Best Master Clock algorithm. The MultiSync 100 supports both IEEE 1588-2008 and the C37.238-2011 Power Profile. Specifics of the 1588-2008 implementation are as follows: The MultiSync 100 is part of a complete end-to-end 1588 time synchronization solution for power system substations and industrial applications. This...

Abrir o catálogo na página 3
MultiSync™ 100 - 4

Ease of configuration The MultiSync 100 provides intuitive software to completely configure all aspects of the clock, as well as to display time synchronization data. Timing and synchronization options include: • Worldwide daylight savings and local time configuration using rule based or fixed date methods • Adjustable holdover times for reliability for poor GPS coverage • Compensation for installation parameters such as GPS signal delay through antenna cable • Programmable outputs include: • IRIG-B (B00x/B22x) time code with selectable IEEE 1344 and AFNOR S87500 extensions • DCF77 time...

Abrir o catálogo na página 4
MultiSync™ 100 - 5

Technical specifications ELECTRICAL OUTPUT OPTIONS OUTPUTS Sync indication output 200 V, 150 mA (max) 2 x TTL outputs • Time codes or pulses or user defined • Electrical specifications: TTL/ CMOS compatible • 0-5 V, 150 mA sink/source • Timing accuracy s 100 ns to UTC NETWORKING GENERAL DHCP VLAN PTP (IEEE 1588 V2) General From 1000 per second to 1 per day with programmable offset & duration • DC level shift • Local or universal time • DC level shift or Modified Manchester • IEEE 1344 extensions (C37.118) • AFNOR NF S87-500 extensions • Local or universal time Auto-configuration with...

Abrir o catálogo na página 5
MultiSync™ 100 - 6

IEC 60068-2-1 Cold Temperature Test Ad -40°C, 16 hours IEC 60068-2-2 Dry Heat Test Bd +85°C, 16 hours IEC 60068-2-30 Humidity (Damp Heat, Cyclic) Test Db 95:%c(|esn-COndenSing), MultiSync 100-P MultiSync 100 1588/C37.238 GPS Clock Copyright 2015, General Electric Company. All Rights Reserved. GE Digital Energy 650 Markland St. Markham, ON Canada L6C 0M1 + 1 877-605-6777 (toll free in North America) + 1 678-844-6777 (direct number) gedigitalenergy@ge.com GEDigitalEnergy.com IEC is a registered trademark of Commission Electrotechnique Internationale. IEEE is a...

Abrir o catálogo na página 6

Todos os catálogos e folhetos técnicos GE Grid Solutions

  1. Kelman TRANSFIX

    2 Páginas

  2. Kelman MINITRANS

    2 Páginas

  3. MIG

    3 Páginas

  4. DTR

    4 Páginas

  5. SPM

    8 Páginas

  6. TOV

    3 Páginas

  7. MDS SD Series

    4 Páginas

  8. MIC

    2 Páginas

  9. Multilin F60

    9 Páginas

  10. Model PT6-2-125

    2 Páginas

  11. Model PT6-1-125

    2 Páginas

  12. Model 3PT3-60

    2 Páginas

  13. MIG II

    8 Páginas

  14. Model JVW-110C

    2 Páginas

  15. Model JVW-5AC-1

    2 Páginas

  16. Model JVW-5C

    2 Páginas

  17. Multilin T60

    9 Páginas

  18. Multilin 489

    9 Páginas

  19. Multilin™ D25

    8 Páginas

  20. Multilin D485

    1 Páginas

  21. Multilin P485

    1 Páginas

  22. MultiNet

    3 Páginas

  23. iNET-II

    4 Páginas

  24. MDS™ iNET 300

    2 Páginas

  25. MDS iNET 900®

    2 Páginas

  26. Multilin L90

    10 Páginas

  27. COSI

    2 Páginas

  28. Reason DR60

    4 Páginas

  29. Multilin 850

    4 Páginas

  30. G650

    8 Páginas

  31. Hydran M2

    2 Páginas

  32. TN1U

    4 Páginas

  33. Multilin™ MM200

    8 Páginas

  34. Multilin™ MM300

    8 Páginas

  35. Multilin 339

    16 Páginas

  36. Multilin 469

    10 Páginas

  37. Multilin A60

    6 Páginas

  38. Multilin 350

    16 Páginas

  39. Multilin F650

    12 Páginas

  40. Multilin 750/760

    10 Páginas

  41. F35

    8 Páginas

  42. 345

    12 Páginas

  43. 745

    8 Páginas

  44. Multilin G30

    9 Páginas

  45. Air-Core Reactors

    8 Páginas

  46. Multilin C30

    6 Páginas

  47. Voltage Regulators

    16 Páginas

  48. g3 Technology

    2 Páginas

  49. Rectifier

    4 Páginas

  50. RMIO

    2 Páginas

  51. Multilin G60

    9 Páginas

  52. Multilin D400

    12 Páginas

  53. GL 107X

    2 Páginas

  54. Disconnectors

    12 Páginas

  55. CGVB-05

    2 Páginas

  56. KOTEF

    4 Páginas

  57. FK

    4 Páginas

  58. B65

    4 Páginas

  59. COSI-RogoFlex

    2 Páginas

  60. MiCOM Agile P24x

    8 Páginas

  61. smorb

    3 Páginas

  62. MIF II

    8 Páginas

  63. SR family

    2 Páginas

  64. 735/737

    4 Páginas

  65. hid

    2 Páginas

  66. dtp

    5 Páginas

  67. M60

    8 Páginas