Multilin 489
1 / 9Páginas

{{requestButtons}}

Excertos do catálogo

Multilin 489 - 1

Grid Solutions Multilin 489 Economical protection, monitoring and metering for generators The Multilin™ 489 Generator Protection System, a member of the SR family of relays, provides protection, control and advanced communications in a cost effective industry leading draw-out construction. Designed for small and medium sized generators, the 489 delivers advanced protection including generator stator differential protection. The 489 also includes detailed diagnostic information allowing for reduced troubleshooting time. • Loss of excitation & Overexcitation • Generator stator differential & 100% stator ground • Distance backup • Reverse power (anti-motoring) • Ground directional overcurrent • Inadvertent energization • Breaker failure • Complete, secure protection of small to medium sized generators • Stator and bearing thermal and vibration monitoring • Easy to use generator protection system supported by and industry leading suite of software tools. • Negative sequence overcurrent • Advanced protection and monitoring features including the use of RTDs for stator and bearing thermal protection and Analog Inputs for vibration monitoring • Global acceptance as a member of the most renown protection relay product family in the market. • Draw-out construction allowing for minimized downtime and easy removal/installation of the 489 during maintenance routines • Networking interfaces - RS232, RS485, 10Mbps copper Ethernet • Large, user-friendly front panel interface allowing for real-time power monitoring and setpoint access with a display that is easily readable in direct sunlight • Multiple protocols - ModBus™ RTU, ModBus™ TCP/IP, DNP 3.0 Level 2 • Enhanced generator troubleshooting through the use of IRIG-B time synchronized event records, waveform capturing, and data loggers • Simplified setpoint verification testing using built in waveform simulation functionality • Cost effective access to information through industry standard communication hardware (RS232, RS485, 10BaseT Ethernet) and protocols (Modbus RTU, Modbus TCP/IP, DNP 3.0) • Available for use in most extreme harsh locations with the available Harsh Chemical Environment Option Applications • Synchronous or induction generators operating at 25Hz, 50Hz or 60Hz • Primary or backup protection in cogeneration applications Monitoring & Metering • Metering – current, voltage, power, Energy, frequency, power factor • Demand – current, watts, vars, VA • Temperature – 12 RTD inputs • Vibration and Speed – 4 analog transducer inputs • Oscillography – 12 samples/ cycle up to 128 cycles in length • Trending – 8 parameters with up to a 5 second sample rate EnerVista Software • Document and software archiving toolset to keep information up to date • Ease to use real time monitoring, control, and data archiving software available • EnerVista Integrator providing easy in

Abrir o catálogo na página 1
Multilin 489 - 2

489 Generator Protection System Sensitive Directional Power The 489 Generator Protection System provides comprehensive protection, metering, and monitoring of small to medium sized synchronous or induction generators operating at 25, 50 or 60 Hz. The 489 is ideally suited for primary or backup generator protection as well as for use in cogeneration applications. Protection features found in the 489 include: 100% stator ground fault protection is provided through an overvoltage element and an adaptive voltage differential feature responding to the unbalance of the third harmonic at the...

Abrir o catálogo na página 2
Multilin 489 - 3

489 Generator Protection System Loss of Excitation Generator loss of excitation protection is provided through two negative offset mho characteristics as per IEEEC37.102 and has independent pickup delay setting for each characteristic. The loss of excitation element will be blocked from tripping if a VT fuse fail condition is detected or if the Voltage Supervision characteristic is enable and the voltage is measured to be above the user defined level. a negative sequence definite time overcurrent alarm element and a negative sequence timed overcurrent curve tripping element to ensure the...

Abrir o catálogo na página 3
Multilin 489 - 4

489 Generator Protection System Analog Inputs Four analog inputs are available for providing protection and monitoring of generator bearing vibration. The analog inputs are field programmable to measure transducer signals that operator over a range of 0 to 1 mA, 0 to 20 mA, or 4 to 20 mA. Analog Outputs Four analog outputs are available for signaling the value of measured analog quantities to external process control devices such as PLCs. The analog outputs can be ordered to operate over a 4 to 20mA range or a 0 to 1mA range and can be configured to signal a representation of most analog...

Abrir o catálogo na página 4
Multilin 489 - 5

489 Generator Protection System EnerVista Software The EnerVista Suite is an industry-leading set of software programs that simplify every aspect of using the 489 relay. The EnerVista suite provides all the tools to monitor the status of your protected asset, maintain the relay and integrate information measured by the 489 into DCS or SCADA monitoring systems. Convenient COMTRADE and Sequence of Events viewers are an integral part of the 489 Setup software included with every relay to carry out postmortem event analysis. EnerVista Launchpad EnerVista Launchpad is a powerful software package...

Abrir o catálogo na página 5
Multilin 489 - 6

489 Generator Protection System Typical Wiring Multilin 489 Generator Protection System

Abrir o catálogo na página 6
Multilin 489 - 7

489 Generator Protection System Viewpoint Monitoring Viewpoint Maintenance EnerVista Integrator Viewpoint Monitoring is a simple-to-use and full-featured monitoring and data recording software package for small systems. Viewpoint Monitoring provides a complete HMI package with the following functionality: Viewpoint Maintenance provides tools that will create reports on the operating status of the relay, simplify the steps to download fault and event data, and reduce the work required for cyber-security compliance audits. Tools available in Viewpoint Maintenance include: EnerVista Integrator...

Abrir o catálogo na página 7

Todos os catálogos e folhetos técnicos GE Grid Solutions

  1. Kelman TRANSFIX

    2 Páginas

  2. Kelman MINITRANS

    2 Páginas

  3. MIG

    3 Páginas

  4. DTR

    4 Páginas

  5. SPM

    8 Páginas

  6. TOV

    3 Páginas

  7. MDS SD Series

    4 Páginas

  8. MIC

    2 Páginas

  9. Multilin F60

    9 Páginas

  10. Model PT6-2-125

    2 Páginas

  11. Model PT6-1-125

    2 Páginas

  12. Model 3PT3-60

    2 Páginas

  13. MIG II

    8 Páginas

  14. Model JVW-110C

    2 Páginas

  15. Model JVW-5AC-1

    2 Páginas

  16. Model JVW-5C

    2 Páginas

  17. Multilin T60

    9 Páginas

  18. Multilin™ D25

    8 Páginas

  19. Multilin D485

    1 Páginas

  20. Multilin P485

    1 Páginas

  21. MultiNet

    3 Páginas

  22. iNET-II

    4 Páginas

  23. MDS™ iNET 300

    2 Páginas

  24. MDS iNET 900®

    2 Páginas

  25. Multilin L90

    10 Páginas

  26. COSI

    2 Páginas

  27. Reason DR60

    4 Páginas

  28. Multilin 850

    4 Páginas

  29. G650

    8 Páginas

  30. Hydran M2

    2 Páginas

  31. TN1U

    4 Páginas

  32. Multilin™ MM200

    8 Páginas

  33. Multilin™ MM300

    8 Páginas

  34. Multilin 339

    16 Páginas

  35. Multilin 469

    10 Páginas

  36. Multilin A60

    6 Páginas

  37. Multilin 350

    16 Páginas

  38. Multilin F650

    12 Páginas

  39. Multilin 750/760

    10 Páginas

  40. F35

    8 Páginas

  41. 345

    12 Páginas

  42. 745

    8 Páginas

  43. Multilin G30

    9 Páginas

  44. Air-Core Reactors

    8 Páginas

  45. Multilin C30

    6 Páginas

  46. Voltage Regulators

    16 Páginas

  47. g3 Technology

    2 Páginas

  48. Rectifier

    4 Páginas

  49. RMIO

    2 Páginas

  50. MultiSync™ 100

    6 Páginas

  51. Multilin G60

    9 Páginas

  52. Multilin D400

    12 Páginas

  53. GL 107X

    2 Páginas

  54. Disconnectors

    12 Páginas

  55. CGVB-05

    2 Páginas

  56. KOTEF

    4 Páginas

  57. FK

    4 Páginas

  58. B65

    4 Páginas

  59. COSI-RogoFlex

    2 Páginas

  60. MiCOM Agile P24x

    8 Páginas

  61. smorb

    3 Páginas

  62. MIF II

    8 Páginas

  63. SR family

    2 Páginas

  64. 735/737

    4 Páginas

  65. hid

    2 Páginas

  66. dtp

    5 Páginas

  67. M60

    8 Páginas