Elemec plus - Digitally Controlled Public Address and General Alarm System
1 / 5Páginas

Excertos do catálogo

Elemec plus - Digitally Controlled Public Address and General Alarm System - 1

GAI-Tronics Systems Elemecplus Digitally Controlled PA and Alarm System PA/GA With Class ‘D’ Amplifier, for Oil and Gas Markets • • Multiple Hot Standby power amplifiers • Plug and socket construction for easy maintenance • Up to 16 fully monitored full featured microphone access panels over 3-pair cable • Message storage and replay up to 2 mins • Auto access panel lockout on panel failure (time-configurable) • System status and fault log monitoring via Ethernet link • Emergency Access fallback operation • In addition to General Paging and Emergency Broadcasts, Alarms can be automatically initiated, e.g. from fire and gas alarm and emergency shut down systems. Alarm tones or pre-recorded digital voice evacuation messages can be broadcast. Compliant to UKOOA, PFEER, IMO, SOLAS, DNV, NORSOK requirements / guidelines • The equipment is specifically and fundamentally designed for failsafe operation, with extensive system and fault status monitoring for maximum availability at all times. Fully duplicated, duplicated or single configuration • The Elemecplus high integrity Public Address & Alarm System is commonly used on Oil & Gas Platforms, FPSO's, Power Stations & Oil Refineries, Chemical Plants & Industrial Complexes Worldwide where the safety of all personnel is of immense importance. Up to 19.2 kW (64 amplifiers) of Audio Power per system • The Elemecplus is a digitally controlled Public Address and General Alarm System (PA/GA). Designed principally for life critical installations in the Oil and Gas market, it is also suitable for many industrial communications requirements. 600W Intelligent Power Amps Intrinsically Safe (I.S.) ATEX microphone panels to Group IIB • Auxiliary Audio Input e.g. music • CE Compliant • PABX Telephone & Page/Party® Access • Engineers Test Panel provision • Fibre Optic link to remote amplifiers • Auto alarm override feature • Supports Alarm Zoning requirements • Amplifier Sub-Zoning • Two priority levels for routine speech • Beacon Cable Monitoring • Ultrasonic Loudspeaker Network Monitoring

Abrir o catálogo na página 1
Elemec plus - Digitally Controlled Public Address and General Alarm System - 2

GAI-Tronics Systems Elemecplus Digitally Controlled PA and Alarm System PA/GA With Class ‘D’ Amplifier, for Oil and Gas Markets PA Controller Speech and audible alarms in the event of processor failure. For ease of installation and maintenance all cabinet internal connections are on a plug/socket basis. The software control is designed to be as flexible as possible, and can easily be downloaded to the Controller. As a security measure, Alarm Tone types can only be changed by replacing an I.C. (EPROM) on the main PCB within the Controller. The centre of the Elemecplus PA/GA system is the...

Abrir o catálogo na página 2
Elemec plus - Digitally Controlled Public Address and General Alarm System - 3

GAI-Tronics Systems Elemecplus Digitally Controlled PA and Alarm System PA/GA With Class ‘D’ Amplifier, for Oil and Gas Markets Intelligent Power Amplifier The field proven D600i amplifier is designed for performance in a range of applications, from continuous 300W RMS rated outputs for Alarm Systems to high quality music reproduction. Each amplifier comprises 2 x 300W channels, each capable of independent operation. At the heart of all GAI-Tronic Public Address Systems is the D600i Class D Power Amplifier (2x300W). The D600i is designed for use in GAI-Tronics high integrity Elemec, NOVA...

Abrir o catálogo na página 3
Elemec plus - Digitally Controlled Public Address and General Alarm System - 4

Three keyswitches are provided - functionality is as follows: - Used for duplicated A/B systems. Either system A or B can be set on master to source audible alarms or voice recorded messages. - Used to select either local or remote Power Amplifiers to be driven by the controller. - Used to inhibit Auto Alarm inputs e.g. to prevent false alarms during F & G system commissioning. Mild Steel • Power 24V DC +/-10% <100mA (unit itself) • 100mA fused outputs provided for Access Panels, • Microphone Panel Audio Input 2.2V p.p. 6000 • Microphone Panel Data, RS485 semi-duplex • Page/Party interface...

Abrir o catálogo na página 4
Elemec plus - Digitally Controlled Public Address and General Alarm System - 5

GAI-Tronics Systems Elemecplus Digitally Controlled PA and Alarm System PA/GA SERIAL SYSTEM INTERLINK 6 PAIR UP TO 16 INTRINSICALLY SAFE REMOTE ACCESS PANELS RACK ‘A’ 3 PAIR ALARM ACCESS Ex PAGE PARTY ACCESS RS232 FAULT/EVENT LOG PABX ACCESS 24 RELAY O/P’S Ex BEACONS LOCAL LOUDSPEAKERS MUTE DUPLICATED AT EACH POINT Ex LOUDSPEAKERS UP TO 8 BROADCAST ZONES RACK ‘B’ POWER AMPLIFIER 19” ACCESS PANEL PA CONTROLLER With Class ‘D’ Amplifier, for Oil and Gas Markets GAI-Tronics® - United Kingdom - Tel: +44 (0)1283 500500 - Fax: +44 (0)1283 500400 - www.gai-tronics.co.uk GAI-Tronics® (Corporate) -...

Abrir o catálogo na página 5

Todos os catálogos e folhetos técnicos GAI-TRONICS

  1. Public Help

    2 Páginas

  2. LED Strobe

    2 Páginas

  3. Rugged Telephone

    12 Páginas

  4. Hood 16dB

    1 Páginas

  5. Help Point PHP400

    2 Páginas

  6. Help Point VR

    2 Páginas

  7. Hood 23dB

    2 Páginas

  8. RigCom

    2 Páginas

  9. Sentinel

    2 Páginas

  10. Titan Telephone

    2 Páginas

  11. Titan GSM (GSM-R)

    2 Páginas

  12. VR Help Point

    2 Páginas

  13. VoIP Clean phone

    2 Páginas

  14. Help Points

    2 Páginas

  15. Elemecplus

    5 Páginas

  16. GSM (GSM-R) Titan

    2 Páginas

  17. VoIP Auteldac 4

    2 Páginas

  18. PHP400 Help Point

    2 Páginas

  19. Hood: 23dB

    2 Páginas

  20. Hood Post

    1 Páginas

  21. Accessories

    2 Páginas

  22. Ex Sounder

    2 Páginas

  23. Hood 9dB

    1 Páginas

  24. Titan For Rail

    2 Páginas

  25. Sonic Alarm

    4 Páginas

  26. PullSwitch

    1 Páginas