Excertos do catálogo

Bulletin 71.2:299H September 2012 299H Series Pressure Reducing Regulators • Inlet Pressure up to 175 psig / 12.1 bar • ±1% Accuracy for Fixed Factor Billing (PFM) • Rugged Construction • Compact • Easy to Maintain • Integral Pilot W7513 Figure 1. 299H Series Pressure Reducing Regulators • Optional Slam-Shut Configuration • No Bleed Monitor • High Capacity • Robust • Outlet Pressures up to 60 psig / 4.1 bar • Optional Token Relief www.fisherregulators.com D102683X012 • External, Internal, or Dual Registration
Abrir o catálogo na página 1
Bulletin 71.2:299H Specifications Specifications for 299H Series constructions are given below. Some specifications for a given regulator as it originally comes from the factory are stamped on a nameplate located on the actuator upper casing. Available Constructions Type 299H: Pilot-operated pressure reducing regulator with a pilot integrally mounted to the actuator casing. Type 299HR: A Type 299H with a token internal relief valve to relieve minor overpressure caused by thermal expansion. Type 299HS: Same as the Type 299H with a Type VSX-2 slam-shut valve which provides overpressure or...
Abrir o catálogo na página 2
Bulletin 71.2:299H 3/4 NPT CONTROL LINE W7527-1 W7528-1 TYPE 299H WITH EXTERNAL REGISTRATION TYPE 299HR PILOT WITH OPTIONAL TOKEN RELIEF Figure 2. 299H Series Sectional Views Features • Compact in Size—Small envelope because of the built-in pilot and internal registration. • Unique No Bleed Monitor System—Flexible worker/monitor system setup that allows for bleed to be piped to the intermediate piping thus eliminating downstream bleed which reduces lost and unaccounted for gas. Another advantage of this configuration is that the system lockup pressure is that of the worker instead of the...
Abrir o catálogo na página 3
Bulletin 71.2:299H Introduction Principle of Operation Description Letter keys in this section refer to Figure 3 unless otherwise noted. Fast response and accuracy are made possible by the amplifying effect of the pilot and by the two-path control system. The function of the pilot is to sense change in the controlled outlet pressure and amplify it into a larger change in the loading pressure. Any changes in outlet pressure act quickly on both the actuator diaphragm and the loading pilot, thus providing the precise pressure control and fast speed of response that is characteristic of a...
Abrir o catálogo na página 4
Bulletin 71.2:299H B J OUTLET E H INLET 3/4 NPT CONTROL LINE CONNECTION K PILOT SUPPLY SCREEN G A C F A7268_1 TYPE 299H WITH INTERNAL REGISTRATION J 3/4 NPT DOWNSTREAM CONTROL LINE CONNECTION J 3/4 NPT DOWNSTREAM CONTROL LINE CONNECTION G A7269 EXTERNAL REGISTRATION A7270 G DUAL REGISTRATION INLET PRESSURE OUTLET PRESSURE ATMOSPHERIC PRESSURE LOADING PRESSURE Figure 3. Type 299H Operational Schematic A7272 A7271 TOKEN RELIEF CLOSED TOKEN RELIEF OPEN Figure 4. Type 299HR Operational Schematic 5
Abrir o catálogo na página 5
HS Type 299HS Bulletin 71.2:299H July 2008 Type 299HS TERNAL REGISTRATION EXTERNAL REGISTRATION EXTERNAL REGISTRATION INTERNAL REGISTRATION TERNAL REGISTRATION E0072 E0072 INLET PRESSURE OUTLET PRESSURE ATMOSPHERIC PRESSURE LOADING PRESSURE E0072 URE SURE C PRESSURE SSURE INTERNAL REGISTRATION INLET PRESSURE OUTLET PRESSURE ATMOSPHERIC PRESSURE LOADING PRESSURE Figure 5. Type 299HS Operational Schematic Type 299H In operation, assume the outlet pressure is less than the setting of pilot control spring (A). The top side of pilot diaphragm assembly (F) will have a lower pressure than the...
Abrir o catálogo na página 6
Table 1. Body Sizes and End Connection Styles Table 2. Outlet Pressure Ranges Refer to Figure 5. The Type VSX-2 slam-shut device on the Type 299HS regulator is a fast acting slam-shut valve which provides overpressure or overpressure and underpressure protection by completely shutting off the flow of gas to the downstream system. The slam-shut module's actions are independent of the Type 299HS main regulator and of variations to the inlet pressure. The Type VSX-2 has internal or external registration. External registration requires a downstream sensing line. The slam-shut disk is held in...
Abrir o catálogo na página 7
OPTIONAL PILOT SUPPLY FILTER OR FILTERED PILOT ' SUPPLY REGULATOR OPTIONAL PILOT SUPPLY REGULATOR OPTIONAL PILOT OPTIONAL PILOT SUPPLY FILTER OR FILTERED PILOT SUPPLY REGULATOR NOTE: IF USED, THE PILOT SUPPLY REGULATOR SHOULD BE SET TO 3 psig / 0.21 bar ABOVE THE MONITOR OUTLET PRESSURE SETTING. NOTE: IF USED, THE PILOT SUPPLY REGULATOR SHOULD BE SET TO 3 psig / 0.21 bar ABOVE THE MONITOR OUTLET PRESSURE SETTING. WIDE-OPEN DOWNSTREAM MONITOR WIDE-OPEN UPSTREAM MONITOR .OPTIONAL PILOT SUPPLY REGULATOR OPTIONAL PILOT SUPPLY FILTER OR FILTERED PILOT SUPPLY REGULATOR OPTIONAL PILOT FILTERED...
Abrir o catálogo na página 8
Table 3. Flow Coefficients Table 4. Type VSX-2 High and Low Trip Pressure Ranges
Abrir o catálogo na página 9
Bulletin 71.2:299H Wide-Open Monitor The control line of the upstream regulator is connected downstream of the second regulator (Figure 6), so that during normal operation the monitoring regulator is standing wide open with the reduction to distribution pressure being taken across the working regulator. Only in case of open failure of the working regulator does the wide-open monitoring regulator take control at its slightly higher setting. A pressure build-up above the monitor set pressure is required for the monitor to take control in the event of an overpressure situation. Installing a...
Abrir o catálogo na página 10
Table 5. Types 299H and 299HR Flow Capacities'1' for 1-1/2 NPT and NPS 2/DN 50 External/Dual Registration
Abrir o catálogo na página 11
Table 5. Types 299H and 299HR Flow Capacities'1' for 1-1/2 NPT and NPS 2/DN 50 External/Dual Registration (continued)
Abrir o catálogo na página 12
Table 5. Types 299H and 299HR Flow Capacities'1' for 1-1/2 NPT and NPS 2/DN 50 External/Dual Registration (continued)
Abrir o catálogo na página 13
Table 6. Types 299H and 299HR Flow Capacities'1' for 1-1/2 NPT Internal Registration
Abrir o catálogo na página 14
Table 6. Types 299H and 299HR Flow Capacities'1' for 1-1/2 NPT Internal Registration (continued)
Abrir o catálogo na página 15
Table 6. Types 299H and 299HR Flow Capacities'1' for 1-1/2 NPT Internal Registration (continued)
Abrir o catálogo na página 16Todos os catálogos e folhetos técnicos FISHER REGULATORS
-
™ Control Valves and Instruments
16 Páginas
-
Run with higher performing,
16 Páginas
-
R Series
2 Páginas
-
RESIDENTIAL REGULATORS Type B NG
8 Páginas
-
LP-Gas Technologies
118 Páginas
-
Industrial Regulators
2 Páginas
-
Type 92B Pressure Reducing Valve
16 Páginas
-
Type 630R Relief Valve
8 Páginas
-
1301 Series High-Pressure Regulators
8 Páginas
-
Fisher™ 657 and 667 Diaphragm Actuators
16 Páginas
-
Fisher™ 4660 High-Low Pressure Pilot
12 Páginas
-
Fisher™ 585C Piston Actuators
16 Páginas
-
Type 630 Regulator
16 Páginas
-
Y696VR Series Vacuum Regulator
4 Páginas
-
Fisher™ YD and YS Control Valves
24 Páginas
-
Sliding-Stem Packing Selection
8 Páginas
-
easy-e Cryogenic Valves
12 Páginas
-
Large ET and ED Valves
20 Páginas
-
Sliding-Stem Live-Loaded Packing
8 Páginas
-
T205 Series Tank Blanketing Regulators
32 Páginas
-
627 Series Pressure Reducing Regulators
36 Páginas
-
1305 Series Regulators
4 Páginas
-
EZR Series Pressure Reducing Regulator
32 Páginas
-
H200 Series Relief Valves
4 Páginas
-
Type 99 Pressure Reducing Regulator
20 Páginas
-
912N Series Pressure Regulators
4 Páginas
-
Building Reliability, from the Ground Up
12 Páginas
-
Air Application Map
1 Páginas
-
DeltaV Controller Firewall
11 Páginas
-
Authoring Comprehensive Recipes
8 Páginas
-
Lifecycle Services for DeltaV Systems
13 Páginas
-
CSI 6500 Overview
12 Páginas
-
The Criticality of Cooling
5 Páginas
-
Ovation Security Center
4 Páginas
-
Laser Alignment Using the CSI 2140
5 Páginas
-
DeltaV Smart Switches
28 Páginas
-
Smartprocess™ Heater
5 Páginas
-
FPSO Industry Solution
2 Páginas
-
Emerson Solutions for Ammonia Production
12 Páginas
-
Fisher ™ Z500 Severe Service Ball Valves
12 Páginas
-
LP-Gas Equipment Buyers Guide LP-31
96 Páginas
-
LP-31
96 Páginas
-
CS 200 series
2 Páginas
-
Regulators Mini Catalog
24 Páginas
-
1301F, 1301G
12 Páginas
-
MR95 and MR98
2 Páginas
-
Fisher® D and DA Valves
12 Páginas
-
Fisher® EZ easy-e Control Valve
40 Páginas
-
Fisher® YD and YS Control Valves
24 Páginas
-
Fisher® EH and EHA Control Valves
36 Páginas
-
Fisher® TBX Steam Conditioning Valve
24 Páginas
-
Fisher® HPNS Control Valve
36 Páginas
-
Fisher® CVX Steam Conditioning Valve
24 Páginas
-
Fisher® 4320 Wireless Position Monitor
12 Páginas
-
Fisher® HP Series Control Valves
28 Páginas
-
Fisher® CAV4 Control Valve
28 Páginas
-
Fisher® 377 Trip Valve
20 Páginas
-
Fisher® V260 Ball Control Valve
8 Páginas
-
EZR Pressure Reducing Regulator
36 Páginas
-
133 Series Self-Operated Regulators
24 Páginas
-
630 Regulator
16 Páginas
-
627F Pressure Reducing Regulator
12 Páginas
-
LR125 Pressure Reducing Liquid Regulator
12 Páginas
-
ACE97 Pad-Depad Valve
16 Páginas
-
ACE95jr Tank Blanketing Valve
8 Páginas
-
ACE95 and ACE95Sr Tank Blanketing Valves
12 Páginas
-
T205B Balanced Tank Blanketing Regulator
24 Páginas
-
T205 Series Tank Blanketing Regulators
32 Páginas
-
627 Series Pressure Reducing Regulators
32 Páginas
-
310A Pressure Reducing Regulator
16 Páginas
-
S200 series
32 Páginas
-
R622 series
8 Páginas
-
Type HSR Pressure Regulators
20 Páginas
-
cs200 series
40 Páginas
-
CS400 Series
60 Páginas
-
912N Series Pressure Regulators
4 Páginas
-
133 Series Self-Operated Regulator
20 Páginas
-
67D Series Pressure Reducing Regulators
12 Páginas
-
67C Series Instrument Supply Regulator
12 Páginas
-
167D Series Switching Valves
8 Páginas
-
95 Series Industrial Pressure Regulators
40 Páginas
-
1301 Series High-Pressure Regulators
8 Páginas
Catálogos arquivados
-
Kinematic Viscosity - Centistokes
1 Páginas
-
Vapor Pressures of LP-Gas
1 Páginas
-
Pipe and Tubing Sizing
1 Páginas
-
Orifice Capacities for LP-Gas
1 Páginas
-
Average Properties of LP-Gas
1 Páginas
-
Pressure Equivalents
1 Páginas