Up to 5 different blanking modes can be stored in the BLCT / ILCT or BLVT / ILVT. With the external selector switch the storedblanking modes can be switchover and recalled.After switchover or an interruption in the voltage supply, the current blanking mode is retained in the light curtain until the selectorswitch is moved to a different setting and the key switch is operated again. Programming must only be performed by authorized personnel. The key switch for enabling programming must beremoved again immediately after programming is complete. The light curtain's current resolution must be...
Abrir o catálogo na página 14
actuate for 2 sec.actuate for 2 sec. Static blanking with 1-beam reduced resolution Static blanking with 2-beam reduced resolution > actuate for 2 sec.actuate for 2 sec. Only ignore 2 beam once Only ignore 1 beam once actuate for 2 sec. Static blanking > Fiessler Elektronik GmbH & Co. KGKastellstr. 9 D 73734 Esslingen BA_BLPG_BPSG_1141 Phone: +49(0)711 / 91 96 97-0Internet: http://www.fiessler.deFax: +49(0)711 / 91 96 97-50eMail: info@fiessler.de 15 size="-1">
Abrir o catálogo na página 15
Bild 16/1 Fiessler Elektronik GmbH & Co. KGKastellstr. 9 D 73734 Esslingen BA_BLPG_BPSG_1141 Phone: +49(0)711 / 91 96 97-0Internet: http://www.fiessler.de
Abrir o catálogo na página 16
The BPSG controller fulfils the power-failure bridging standard of 20 ms specified by EN 60204 and is therefore suitable for supplying the LCT and LVT light curtain with voltage. > (only in conjunction with the BLCT/ILCT BLVT/ILVTlight curtain) Functions Protection type IP 20 Protection classAmbient operatingtemperature Protective insulation-10 to 55 C Storagetemperature -25 to 70 C > BLPG: 24 V DC + 20% - 10%BPSG: 230 V AC/50Hz +10% -15%, 115 V AC/50Hz +10% -15% or 24 V DC, + 20% - 10% Supply voltage The output contacts are potential-free, force-guided and normally open with a maximum...
Abrir o catálogo na página 17
Refer to the light curtain operating manual forimportant notes and constraints. All safety instructions are marked with this symbol and must be observed in particular! Safe functionality of the entire installation is guaranteed only if this operating manual and applicable accident-prevention regulations are observed.Forming part of the controller's scope of delivery, this operating manual must be kept at the controller's -The Access to the hazardous area safety distance between the protective field andhazardous area must be large enough to ensure that,
Abrir o catálogo na página 18Todos os catálogos e folhetos técnicos Fiessler Elektronik
-
RAZL-2
8 Páginas
-
FMSC Safety controller
16 Páginas
-
FMSC Systemfamily
4 Páginas
-
Safety-contact-mat STM
12 Páginas
-
Product Catalog
172 Páginas
Catálogos arquivados
-
LSUW NSR3-1 K
6 Páginas
-
LSUW 24V Operating Instructions
46 Páginas
-
SAFETY LIGHT BARRIERS
4 Páginas