TEST CHAMBERS
1 / 24Páginas

Excertos do catálogo

TEST CHAMBERS - 1

test chambers Climatic Test Chambers Stability Test Chambers Growth Test Chambers

Abrir o catálogo na página 1
TEST CHAMBERS - 3

TEST CHAMBERS 5 I CLIMATIC TEST CHAMBERS 6 I Climatic Chambers with and without humidity control Vertical Airflow 11 12 12 STABILITY TEST CHAMBERS Stability Chambers with and without humidity control Horizontal Airflow Stability Chambers with and without humidity control Horizontal Airflow for ICH Test FORCED AIR GROWTH TEST CHAMBERS Growth Chambers with and without humidity control Vertical and Horizontal Airflow Application table

Abrir o catálogo na página 3
TEST CHAMBERS - 4

CLIMATIC TEST CHAMBERS CLIMATIC TEST CHAMBERS - VERTICAL AIRFLOW • Without humidity (FCC Series) • With humidity (FCC-H Series) STABILITY TEST CHAMBERS STABILITY TEST CHAMBERS - HORIZONTAL AIRFLOW • Without humidity - FSC Series - FSC For ICH Test Series • With humidity FSC-H Series - FSC-H For ICH Test Series FORCED AIR GROWTH TEST CHAMBERS GROWTH TEST CHAMBERS - VERTICAL AIRFLOW • Without humidity - Light on the door (GVD Series) - Lights on the door and two sides (GVS Series) • With humidity - Light on the door (GVD-H Series) - Lights on the door and two sides (GVS-H Series) GROWTH TEST...

Abrir o catálogo na página 4
TEST CHAMBERS - 5

CLIMATIC TEST CHAMBERS 6 6 TEST CHAMBERS CLIMATIC TEST CHAMBERS Climatic Chambers with and without humidity control Vertical Airflow

Abrir o catálogo na página 5
TEST CHAMBERS - 6

CLIMATIC TEST CHAMBERS Climatic Chambers with and without humidity control - Vertical Airflow Food industry Confectionary industry Laboratory testing Analytical laboratory Pharmaceutical industry Quality test Environmental test Construction materials industry Calibration laboratory Biotechnology Texile industry Automotive industry Electronic industry Plastic industry Optionally -10°/-20°/-30°C to +60°C without humidity control CLIMATIC TEST CHAMBERS VERTICAL AIRFLOW Without Humidity With Hum

Abrir o catálogo na página 6
TEST CHAMBERS - 7

CLIMATIC TEST CHAMBERS Climatic Chambers with and without humidity control - Vertical Airflow STANDARD FEATURES • • • • Cooling system controller by solenoid electrovalves Adjustable safey thermostat to protect the samples System setting protected by password Key lock on the door Temperature range from +4°C to +60°C (optionally from -10/-20/-30°C to +60°C without humidity control) Models include forced air refrigeration (distributed uniformly vertically), and have high temperature homogeneity inside of the chamber Ultrasound humidity generator, introducing microscopic water drops inside of...

Abrir o catálogo na página 7
TEST CHAMBERS - 8

CLIMATIC TEST CHAMBERS Climatic Chambers with and without humidity control - Vertical Airflow FCC/FCC-H 940 FCC/FCC-H 1500 FCC/FCC-H 2200 Capacity Lt 350 Nr of shelves 2 Nr max of shelves 4 1 Nr of doors Compressor RH 1/2 Usable Internal Dimensions (WxDxH) mm 820x540x660 External dimensions (WxDxH) mm 925x800x1140 Climatic Chamber - Vert. Airflow without Humidity FCC 701.1100.01 Climatic Chamber - Vert. Airflow with Humidity FCC-H 701.1101.01 TEST CHAMBERS

Abrir o catálogo na página 8
TEST CHAMBERS - 9

CLIMATIC TEST CHAMBERS Climatic Chambers with and without humidity control - Vertical Airflow OPTIONAL ACCESSORIES • • • • • Temperature range from +4°C to +60°C (optionally from -10/-20/-30°C to +60°C without humidity control) Humidity generator up to +95°C RH Air drying system up to 15% RH at +4°C Additional access ports to introduce cables and probes Thermal glass door, with heated frame in models with humidity control or lower temperatures External stainless steel finish Plugs inside of the chamber Potential free output for remote alarm control UV light tubes for sterilization...

Abrir o catálogo na página 9
TEST CHAMBERS - 10

HOW TO CONFIGURE FALC CLIMATIC TEST CHAMBERS Falc Test Chambers are suitable for creating environmental conditions to test samples by combining three variables: temperature, humidity and lights. Considering the many combinations of these variables, we suggest you to directly configure the instrument with the manufacturer, providing all the necessary information, including the application and the mode of use. The temperature and the humidity of both Climatic Chambers and Stability Chambers need a close attention: Just as the temperature can reach -30 ºC, requiring a specific refrigeration...

Abrir o catálogo na página 10
TEST CHAMBERS - 11

STABILITY TEST CHAMBERS 12 12 12 STABILITY TEST CHAMBERS Stability Chambers with and without humidity control Horizontal Airflow Stability Chambers with and without humidity control Horizontal Airflow for ICH Test

Abrir o catálogo na página 11
TEST CHAMBERS - 12

STABILITY TEST CHAMBERS Stability Chambers with and without humidity control - Horizontal Airflow Laboratory testing Quality test Chemical industry Environmental test Food industry HORIZONTAL AIRFLOW FSC SERIES Optionally -10°/-20°/-30°C to +60°C without humidity control Touchscreen controller included Stability Chambers with and without humidity control - Horizontal Airflow for ICH Test FIELDS OF APPLICATION: Long term testing at +25°C / 60% RH or +30°C / 65% RH Pharmaceutical industry with ICH test Laboratory testing Quality test Chemical industry Environmental test Food industry Cosmetic...

Abrir o catálogo na página 12
TEST CHAMBERS - 13

STABILITY TEST CHAMBERS Stability Chambers with and without humidity control - Horizontal Airflow STANDARD FEATURES • • • • Cooling system controller by solenoid electrovalves Adjustable safey thermostat to protect the samples System setting protected by password Key lock on the door Temperature range from +4°C to +60°C (optionally from -10/-20/-30°C to +60°C without humidity control) Models include forced air refrigeration (distributed uniformly vertically), and have high temperature homogeneity inside of the chamber Ultrasound humidity generator, introducing microscopic water drops inside...

Abrir o catálogo na página 13
TEST CHAMBERS - 14

STABILITY TEST CHAMBERS Stability Chambers with and without humidity control - Horizontal Airflow 500 - 700 - 940 lt Capacity FSC/FSC-H FSC/FSC-H FSC/FSC-H FSC/FSC-H FSC/FSC-H FSC/FSC-H FSC/FSC-H for FSC/FSC-H for FSC/FSC-H for FSC/FSC-H for FSC/FSC-H for FSC/FSC-H for ICH Test ICH Test ICH Test ICH Test ICH Test ICH Test 350 500 700 940 1500 2200 Capacity Lt 350 500 700 940 1500 2200 Nr of shelves 2 3 4 4 4+4 4+4 Nr max of shelves 4 6 8 8 8+8 8+8 Nr of doors 1 1 1 1 2 2 Compressor RH 1/2 3/8 3/8 3/8 3/8 3/8 Usable dimensions (WxDxH) mm 820x540x660 640x600x1100 640x600x1350 640x890x1350...

Abrir o catálogo na página 14

Todos os catálogos e folhetos técnicos FALC Instruments S.r.l.

  1. Circulation baths

    8 Páginas

  2. Thermostatic baths

    16 Páginas

  3. Autoclaves_2024

    20 Páginas

  4. FURNACES

    8 Páginas

  5. MELTING POINTS

    8 Páginas

  6. THERMOBLOCKS

    12 Páginas

  7. STIRRERS

    20 Páginas

  8. THERMOCYCLERS

    8 Páginas

  9. HEATERS

    16 Páginas

  10. PHMETERS

    32 Páginas

  11. GENERAL CATALOGUE

    130 Páginas

Catálogos arquivados

  1. LABORATORY OVENS

    20 Páginas

  2. INCUBATORS

    20 Páginas

  3. THERMOSTATIC BATHS

    20 Páginas

  4. Ultrasonic Baths

    12 Páginas

  5. AUTOCLAVES

    16 Páginas