Technical Documentation TORRIX RS485 with MODBUS Protocol
Abrir o catálogo na página 1
Supported MODBUS Protocol Variants TORRIX-RS485 with Modbus protocol only supports the Modbus ASCII variant as described in the Modicon Modbus Protocol Reference Guide. Wiring Connections The wiring of the level sensors TORRIX RS485 may only be carried out with the power disconnected. For wiring, proceed as follows: • If not already connected, plug the coupling of the FAFNIR connection cable onto the M12 connector of the sensor head. First tighten the union nut of the M12 connector by hand and then use an open-ended spanner to tighten the nut further 180°. The tightening torque should be...
Abrir o catálogo na página 4
2 MODBUS Register Map Supported Function Codes The following function codes are supported: • Function Code 03 - Read Holding Registers • Function Code 04 - Read Input Registers • Function Code 08 - Diagnostics (only sub-function 00 - Return Query Data) All registers are read only. Support of different output formats The following output formats are supported: 16 bit unsigned integer • Big Endian (most significant byte first): [12] • Little Endian (least significant byte first): [21] 32 bit floating point • Big Endian (straight word order, most significant byte first): [12] [34] •...
Abrir o catálogo na página 5
Values Probe type • 1 = Basic Number of discrete temperature sensors The number of discrete temperature sensors depends on the probe type. Status of probe The probe can be in one of the following states: • 0 = ok
Abrir o catálogo na página 6
2.2 Values formatted in 32 bit floating point format The values formatted according to the IEEE 754 single-precision 32 bit floating point format can be read out using the following two Function Codes: • Function Code 03 - Read Holding Registers • Function Code 04 - Read Input Registers You have to add 30001 or 40001 to the address shown in the table to get the register number. Please take into account that the address shown in the table has a hexadecimal format while the register number has a decimal format. Two consecutive 16 bit registers have to be read to get the complete 32 bit...
Abrir o catálogo na página 7
* Only available if the probe is of type Advanced or Flex. ** Only available if the probe is of type Advanced.
Abrir o catálogo na página 8
32-Bit Floating Point, Measurement Units: US (inch, °F) * Only available if the probe is of type Advanced or Flex. ** Only available if the probe is of type Advanced.
Abrir o catálogo na página 9
FAFNIR 2.3 Exception Codes The following exception codes are supported: • 01 - Illegal Function • 02 - Illegal Data Address • 03 - Illegal Data Value 01 - Illegal Function The exception code Illegal Function is returned under the following circumstances: • A function code other than 03 ,04 or 08 is used • The function code 08 is used with a sub-function code other than 0000 02 - Illegal Data Address The exception code Illegal Data Address is returned under the following circumstances: • The function code 03 or 04 is used with a starting address that is not included in the TORRIX...
Abrir o catálogo na página 10
3 Appendix3.1 Request and Response Formats Requests and Responses for Function Codes 03 and 04 Request * Number of Registers is the number of registers requested and has to be in the range of 1 to 30 ** Byte Count is the number of bytes (not registers) returned *** see Appendix LRC Calculation
Abrir o catálogo na página 11
The LRC of a message has to be calculated as follows: 1. Sum up all bytes of the message, excluding the starting character {:} and the ending characters {cr} and {lf}. The sum is build up in a one-byte field, so all carries will be discarded. 2. Calculate the ones-complement of the sum by subtracting the sum from 0xFF. 3. Calculate the twos-complement of the sum by adding 0x01 to the ones-complement of the sum. This example shows how the LRC of the complete message {:}010300200006D6{cr}{lf} has to be calculated. Note: • control characters of the message shown in brackets • LRC of the...
Abrir o catálogo na página 12
3.3 Communication Examples Read the serial number of the probe The serial number is available in the register pairs 0x0000/0x0001 (Big Endian) and 0x0100/0x0101 (Little Endian). Reading the serial number in Big Endian format from a probe with slave address 1 using Function Code 03 looks like this: Request: {:}010300000002FA{cr}{lf} Response: {:}010304000186ABC6{cr}{lf} Evaluation: Register 0x0000 = 0x0001 Register 0x0001 = 0x86AB O Serial number = 0x000186AB = 100011 Read all static values of the probe Reading all static values in Big Endian format from a probe with slave address 1 using...
Abrir o catálogo na página 13
• 0x0620/0x0621 - format [43][21], Little Endian, Bytes Swapped • 0x0720/0x0721 - format [34][12], Little Endian Reading the level of product from a probe with slave address 1 in metric units and format [43][21] (Little Endian, Bytes Swapped) using Function Code 04 looks like this: Request: {:}010402200002D7{cr}{lf} Response: {:}010404BC942B4438{cr}{lf} Evaluation: Register 0x0220 = 0xBC94 Register 0x0221 = 0x2B44 O Level of product = 0x442B94BC = 686,324 mm Read level of product, level of water and average temperature The level of product is available as 32-bit floating point...
Abrir o catálogo na página 14Todos os catálogos e folhetos técnicos FAFNIR GmbH
-
TORRIX M12 MOBILE
2 Páginas
-
TORRIX XTS
2 Páginas
-
TORRIX 6
1 Páginas
-
LPG Sensors
8 Páginas
-
SEPARIX
8 Páginas
-
Process Automation
28 Páginas
-
O²-PID
4 Páginas
-
COMS Leaflet
4 Páginas
-
VAPORIX Flow and Control
40 Páginas
-
Wallmounting Typ 907
4 Páginas
-
QE 200
4 Páginas
-
UM 2.1/2.2/2.3
20 Páginas
-
TORRIX HART
28 Páginas
-
TORRIX M12
40 Páginas
-
FAFNIR Universal Device Protocol (UDP)
30 Páginas
-
FAFNIR Hart Setup
9 Páginas
-
LS 300 / 500
7 Páginas
-
76 A / NB 220
5 Páginas
-
76 / NB 220
2 Páginas
-
SECON-X
4 Páginas
-
PRESSURIX
12 Páginas
-
Insite360
4 Páginas
-
Plugs
12 Páginas
-
UM 2.1/UM 2.2/UM 2.3
20 Páginas
-
TORRIX-HART
28 Páginas
-
DIVELIX
8 Páginas
-
CONDURIX-HART
28 Páginas
-
CONDURIX
24 Páginas
-
VAPORIX
12 Páginas
-
VISY-X
24 Páginas
-
Accessories
3 Páginas
-
VISY-Command Web
4 Páginas
-
VISY-Reed
4 Páginas
-
VISY-RF
2 Páginas
-
VISY-Stick
15 Páginas
-
VISY-TD Display
2 Páginas
-
VISY-View Touch
2 Páginas
-
VPI - VISY-Power Interface
1 Páginas
-
TORRIX
10 Páginas
-
TORRIX CI
1 Páginas
-
TORRIX RS485
3 Páginas
-
UM-X Transducer
3 Páginas
-
TEMPERIX
8 Páginas
-
Overfill Prevention & Accessories
12 Páginas
-
VISY-Input VISY-Output
4 Páginas
-
VISY-Command
5 Páginas
-
LPG-Sensoren
8 Páginas
Catálogos arquivados
-
2019 VISY-Stick Flex
2 Páginas
-
2016 VISY-Stick Flex
2 Páginas
-
HPH Ex d
3 Páginas
-
VISY-Monitor
2 Páginas
-
VISY-X LON
10 Páginas
-
SEPARIX
23 Páginas
-
VAPORIX Flow/Control
32 Páginas
-
VISY-Setup V 3.1.0
40 Páginas
-
VISY-Setup V2.10
42 Páginas
-
VISY-View
24 Páginas
-
VISY-Stick and VISY-Command
24 Páginas
-
Overfill Prevention (GWG)
12 Páginas