Grupo: Gilbarco Veeder-Root

Excertos do catálogo

Process Automation Process Automation Level Sensors | Level Switches | Overfill Prevention Pressure Sensors | Temperature Sensors Sensors and Systems: www.fafnir.com
Abrir o catálogo na página 1
Process Automation Edition 05.16 Right to technical changes reserved PRESSURIX A Accurately Measure Pressure in All Scenarios: Modular Pressure Sensor The pressure sensor PRESSURIX A uses a smart modular technology. It is suited for measuring the relative and absolute pressure of gases, vapours and liquids. The broad range of process connections allows the device to be deployed in a variety of applications. The pressure diaphragm seal with flange connection is applicable for pressure measurement with aggressive, highly viscous, solidifying or crystallizing media. Using capillary lines for...
Abrir o catálogo na página 2
Process Automation Edition 05.16 Right to technical changes reserved PRESSURIX A/AD – Technical Data Sensor head Protection class Stainless steel 1.4301 (304); Makrolon; Viton Head design Two-chamber system with PTFE pressure compensation filter Cable terminal M16 x 1.5 cable gland for cable diameter 5 to 10 mm; M12 Connector Ambient temperature Sensor Material Stainless steel 1.4404 (316L); Hastelloy® C4; others on request Accuracy Linearity Long-term drift 0.1 %/year of nominal range Temperature effect ±0.15 %/10 K of nominal range (0 °C; to +60 °C); ±0.2 %/10 K of nominal range (<0 °C; >...
Abrir o catálogo na página 3
Process Automation Edition 05.16 Right to technical changes reserved PRESSURIX A ST with a G Vi" thread. PRESSURIX A ST with a G Vi" thread. The housing shown is suitable for The housing shown is suitable for both either a display or a HART® module. display and HART® module. Ideal for most standard applications Process connection G V" B (inline diaphragm) Process conditions Pressure G %” A (DIN 3852) flush-mounted diaphragm (up to 100 bar); G %” B with O-ring flush-mounted diaphragm (up to 40 bar) -0.4 to 0.4 bar up to -1 to 100 bar (relative); Overload limit (1 bar to 200...
Abrir o catálogo na página 4
Process Automation Edition 05.16 Right to technical changes reserved PRESSURIX AD NT with a G Vi" thread for temperatures up to 125 °C. The housing is suitable for either a display or a HART® module. PRESSURIX AD NT with flange and temperature isolator for temperatures up to 160 °C. The housing is suitable for either a display or a HART® module. PRESSURIX AD HHT with G V" thread and capillary for offset installation for temperatures up to 350 °C. The housing is suitable for either a display or a HART® module. PRESSURIX AD with Diaphragm Seal Gives you full flexibility in process connection...
Abrir o catálogo na página 5
Process Automation Edition 05.16 Right to technical changes reserved PRESSURIX S Pressure Sensor for Use in Tough Environments The PRESSURIX S version of our pressure sensor is suitable for applications where a simple 4 to 20mA interface is enough. Thanks to its many different process fittings, it is especially suited when measuring pressure in aggressive, highly viscous, solidifying or crystallizing media. With various electrical connections from a right-angle plug to an M12 plug and fixed cable, to an IP67 protection class field housing, the sensor offers a solution for many types of...
Abrir o catálogo na página 6
Process Automation Edition 05.16 Right to technical changes reserved PRESSURIX S ST with G V2" thread for temperatures up to 80 °C and with field housing PRESSURIX S ST with NPT %" thread for temperatures up to 80 °C and with right-angle plug (Form A) PRESSURIX S NT with G %" thread and temperature decoupler for temperatures up to 140 °C (short term) and with a fixed cable PRESSURIX S NT with G %" thread and temperature decoupler for temperatures up to 140 °C (short term)and with M12 plug PRESSURIX S Ideal for most standard applications Process connection G %" B; %" NPT inline diaphragm...
Abrir o catálogo na página 8
Process Automation Edition 05.16 Right to technical changes reserved PRESSURIX SD NT with G %" thread for temperatures up to 140 °C with field housing PRESSURIX SD NT with a flange for temperatures up to 140 °C and with right-angle plug (Form A) PRESSURIX SD HT with G %" thread and temperature decoupler for temperatures up to 200 °C and with fixed cable PRESSURIX SD HHT with G % thread and a capillary for offset mounting for temperatures up to 350 °C and with M12 connector PRESSURIX SD with Diaphragm Seal Gives you full flexibility in process connection and installation situations Process...
Abrir o catálogo na página 9
Process Automation Edition 05.16 Right to technical changes reserved PRESSURIX C The Most Economic Digital Pressure Measurement Solution The PRESSURIX C is the cost-efficient digital alternative to the PRESSURIX S pressure sensor for full pressure measurement of gases, vapours and liquids. Why Choose PRESSURIX C? Main Features and Benefits ++Accuracy ≤0.3 % ++ Output signal 4 to 20 mA, 2-wire technology ++Process temperature -20 °C to +120 °
Abrir o catálogo na página 10
Process Automation Edition 05.16 Right to technical changes reserved PRESSURIX C – Technical Data Sensor head Protection class Cable terminal Ambient temperature Sensor Stainless steel 1.4301 (304)/1.4542 (630) Material Accuracy Linearity Long-term drift 0.1 %/year of nominal range Temperature effect ±0.2 %/10 K of nominal range (0 °C to +50 °C); ±0.3 %/10 K of nominal range (-20 °C to 0 °C; 50 °C to +80 °C) Response time Adjusting range ±5 % f.s. Zero point and range dependent Electrical connection Connection Process conditions -20 °C to +120 °C 0 to 1 to 0 to 600 bar relative; -1 to 0 to...
Abrir o catálogo na página 11
E-mail: info@fafnir.com Internet: www.fafnir.com
Abrir o catálogo na página 12Todos os catálogos e folhetos técnicos FAFNIR GmbH
-
TORRIX M12 MOBILE
2 Páginas
-
TORRIX XTS
2 Páginas
-
TORRIX 6
1 Páginas
-
LPG Sensors
8 Páginas
-
SEPARIX
8 Páginas
-
Process Automation
28 Páginas
-
O²-PID
4 Páginas
-
COMS Leaflet
4 Páginas
-
VAPORIX Flow and Control
40 Páginas
-
Wallmounting Typ 907
4 Páginas
-
QE 200
4 Páginas
-
UM 2.1/2.2/2.3
20 Páginas
-
TORRIX HART
28 Páginas
-
TORRIX RS485 Modbus
16 Páginas
-
TORRIX M12
40 Páginas
-
FAFNIR Universal Device Protocol (UDP)
30 Páginas
-
FAFNIR Hart Setup
9 Páginas
-
LS 300 / 500
7 Páginas
-
76 A / NB 220
5 Páginas
-
76 / NB 220
2 Páginas
-
SECON-X
4 Páginas
-
Insite360
4 Páginas
-
Plugs
12 Páginas
-
UM 2.1/UM 2.2/UM 2.3
20 Páginas
-
TORRIX-HART
28 Páginas
-
DIVELIX
8 Páginas
-
CONDURIX-HART
28 Páginas
-
CONDURIX
24 Páginas
-
VAPORIX
12 Páginas
-
VISY-X
24 Páginas
-
Accessories
3 Páginas
-
VISY-Command Web
4 Páginas
-
VISY-Reed
4 Páginas
-
VISY-RF
2 Páginas
-
VISY-Stick
15 Páginas
-
VISY-TD Display
2 Páginas
-
VISY-View Touch
2 Páginas
-
VPI - VISY-Power Interface
1 Páginas
-
TORRIX
10 Páginas
-
TORRIX CI
1 Páginas
-
TORRIX RS485
3 Páginas
-
UM-X Transducer
3 Páginas
-
TEMPERIX
8 Páginas
-
Overfill Prevention & Accessories
12 Páginas
-
VISY-Input VISY-Output
4 Páginas
-
VISY-Command
5 Páginas
-
LPG-Sensoren
8 Páginas
Catálogos arquivados
-
2019 VISY-Stick Flex
2 Páginas
-
2016 VISY-Stick Flex
2 Páginas
-
HPH Ex d
3 Páginas
-
VISY-Monitor
2 Páginas
-
VISY-X LON
10 Páginas
-
SEPARIX
23 Páginas
-
VAPORIX Flow/Control
32 Páginas
-
VISY-Setup V 3.1.0
40 Páginas
-
VISY-Setup V2.10
42 Páginas
-
VISY-View
24 Páginas
-
VISY-Stick and VISY-Command
24 Páginas
-
Overfill Prevention (GWG)
12 Páginas