Overfill Prevention and Product Identification for fuel drop at petrol stations Sensors & Systems Worldwide: www.fafnir.com
Abrir o catálogo na página 1
O1-PID Overfill Prevention & Product Identification Benefits of the overfill and cross over prevention system with O1-PID Application The O1-PID System is a safety device to prevent the overfilling of storage and bunker tanks when filled with petrol, diesel or fuel oil. The system consists of an optical liquid detector with product identification (O2-PID) ■ Much easier handling of the fuel drop ■ No extra cable at the road tanker is needed for the overfill prevention ■ The connection to the O1-PID detector is realized by electrically conductive hoses in the storage tank and an evaluation...
Abrir o catálogo na página 2
The connection couplings of the hoses are electrically isolated. Therefore it is possible to supply the O2-PID fluid detector with an intrinsic safe current and to read its measured values. The status of the detector is interrogated 10 times per second. If a liquid touches the optical prism of the O2-PID detector, the status of the detector changes and a corresponding signal is transmitted to the road tanker electronics (PRD). Every evaluation in accordance with EN 14116 can read the PID and overfill information! The System There are three important tasks that are served by the new O2-PID ■...
Abrir o catálogo na página 3
Probe length FAFNIR Technical Data of O2-PID Operating data » Temperature range: -40 °C to +60 °C » Pressure range: 0,1 MPa Optical detection principle » Prism: Polysulfon Materials » Wetted parts: Stainless steel 1.4301 (304); Brass; Viton; Polysulfon Dimensions » Diameter of sensor tube: 16 mm » Length: 600 mm » Screw-in unit G 1 » Cable connection: 2 m of two wire lead Approvals » Overfill prevention device EN 13616 » Communication of PID: EN 14116 » ATEX: II 1 G Ex ia IIB T4 Ga Threshold point FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg, Germany Phone: +49/40/39 82 07-0 E-Mail:...
Abrir o catálogo na página 4Todos os catálogos e folhetos técnicos FAFNIR GmbH
-
TORRIX M12 MOBILE
2 Páginas
-
TORRIX XTS
2 Páginas
-
TORRIX 6
1 Páginas
-
LPG Sensors
8 Páginas
-
SEPARIX
8 Páginas
-
Process Automation
28 Páginas
-
COMS Leaflet
4 Páginas
-
VAPORIX Flow and Control
40 Páginas
-
Wallmounting Typ 907
4 Páginas
-
QE 200
4 Páginas
-
UM 2.1/2.2/2.3
20 Páginas
-
TORRIX HART
28 Páginas
-
TORRIX RS485 Modbus
16 Páginas
-
TORRIX M12
40 Páginas
-
FAFNIR Universal Device Protocol (UDP)
30 Páginas
-
FAFNIR Hart Setup
9 Páginas
-
LS 300 / 500
7 Páginas
-
76 A / NB 220
5 Páginas
-
76 / NB 220
2 Páginas
-
SECON-X
4 Páginas
-
PRESSURIX
12 Páginas
-
Insite360
4 Páginas
-
Plugs
12 Páginas
-
UM 2.1/UM 2.2/UM 2.3
20 Páginas
-
TORRIX-HART
28 Páginas
-
DIVELIX
8 Páginas
-
CONDURIX-HART
28 Páginas
-
CONDURIX
24 Páginas
-
VAPORIX
12 Páginas
-
VISY-X
24 Páginas
-
Accessories
3 Páginas
-
VISY-Command Web
4 Páginas
-
VISY-Reed
4 Páginas
-
VISY-RF
2 Páginas
-
VISY-Stick
15 Páginas
-
VISY-TD Display
2 Páginas
-
VISY-View Touch
2 Páginas
-
VPI - VISY-Power Interface
1 Páginas
-
TORRIX
10 Páginas
-
TORRIX CI
1 Páginas
-
TORRIX RS485
3 Páginas
-
UM-X Transducer
3 Páginas
-
TEMPERIX
8 Páginas
-
Overfill Prevention & Accessories
12 Páginas
-
VISY-Input VISY-Output
4 Páginas
-
VISY-Command
5 Páginas
-
LPG-Sensoren
8 Páginas
Catálogos arquivados
-
2019 VISY-Stick Flex
2 Páginas
-
2016 VISY-Stick Flex
2 Páginas
-
HPH Ex d
3 Páginas
-
VISY-Monitor
2 Páginas
-
VISY-X LON
10 Páginas
-
SEPARIX
23 Páginas
-
VAPORIX Flow/Control
32 Páginas
-
VISY-Setup V 3.1.0
40 Páginas
-
VISY-Setup V2.10
42 Páginas
-
VISY-View
24 Páginas
-
VISY-Stick and VISY-Command
24 Páginas
-
Overfill Prevention (GWG)
12 Páginas