BCU Control unit Benefits • Compact 3-channel actuator control unit • Single fault safety • Overload and over-temperature protection • Approved for medical applications • Easy to clean • Low standby current Technical data Unit Motor ports (DIN8) Operating device ports (HD15) Battery ports Limit switch ports Single fault safety Encoder processing yes/no yes/no Input voltage Frequency Input current (max) Standby power Output voltage Output current (max) Duty cycle: intermittent Duty cycle: short time Ambient temperature Humidity Degree of protection Approvals

Abrir o catálogo na página 4
Control units - 5

Dimensional drawing Connecting diagrams 191 View without connectors interlock Mains cable Connection for 3 actuators Connection hand switch Suitable control units and accessories Operating switches Linear actuators

Abrir o catálogo na página 5
Control units - 6

BCU control unit Voltage 5 120 V AC, 60 Hz, class I 8 230 V AC, 50 Hz, class II Mains power supply cable 2J Class II, straight 3,5 m, 2-pole plug, EU (for voltage type 8) 2H Class II, straight 3,5 m, 2-pole plug, UK (for voltage type 8) 2L Class I, straight 3,5 m, 3-pole plug, UL (for voltage type 5) Soft start/stop 0 Hard 3 Medium 6 Soft (on request) 1) 2) TLT is a 2-motor actuator. If simultaneous run is needed, BCP21-CC... is recommended. Reduced lift capability : CPMT-1 up to 3 000 N, CPMT1-2 up to 4 000 N Actuator 1 Actuator 2 Actuator 3

Abrir o catálogo na página 6
Control units - 8

VCU Control unit Benefits • Compact 5-channel actuator control unit • Single fault safety • Overload and over-temperature protection • Approved for medical applications • Easy to clean • Low standby current Technical data Unit Motor ports (DIN8) Operating device ports (HD15) Battery ports (DSub9) Limit switch ports (HD15) Single fault safety Encoder processing yes/no yes/no Input voltage Frequency Input current (max) Standby power Output voltage Output current (max) Duty cycle: intermittent Duty cycle: short time Ambient temperature Humidity Degree of protection Approvals Weight without...

Abrir o catálogo na página 8
Control units - 9

Dimensional drawing 38 360 Operating voltage display (LED) Suitable control units and accessories Operating switches Linear actuators Hand switch Foot switch Desk switch 1. Two connections for HD15 operating devices 2. HD15 limit switch connection 3. Additional space for mounting 4.

Abrir o catálogo na página 9
Control units - 10

Pinning of HD15 limit switch connection Function 24 V DC (common) Switch 1 Switch 2 NC 20–40 V DC, max. 50 mA GND Connecting diagram 2,9 1,3,5,7,9 white/yellow, white/green, grey–pink, black, blue 1 5 2 brown–green 6 10 4 red–blue 6,8,10,11,12,14 violet, red, pink, grey, yellow, brown 15 11 13 green D=20 15 white Pin 1 Pin 2 Pin 3 Pin 4 Accessories Plug Mains cable, 2 pole Mains cable, 3 pole Mains cable, 3 pole Mains cable, 3 pole Mains cable, 3 pole Mains cable, 3 pole Mains cable, 3 pole Battery pack 2,7 Ah Rack for 4,5 Ah battery Detachable battery 4,5 Ah Order number Euro Schuko SEV UL...

Abrir o catálogo na página 10
Control units - 11

VCU control unit Voltage 5 120 V AC, 60 Hz, class I 8 230 V AC, 50 Hz, class II 9 230 V AC, 50 Hz, class I Number of channels 3 3 channels 5 5 channels Option 1 1 No option (only VCUx3) 2 Prepared for mounting of battery Transformer 1 7 A transformer 3 18 A transformer (for 5-channel version only) VCU parameterization Functionality 11 All channels individually 2 channels simultaneously + 1 21 or 3 individually 22 2 + 2 channels simultaneously + 1 individually 30 All channels simultaneously, only 3-channel version 4 channels simultaneously + 1 individually, 41 only 5-channel version 50 All...

Abrir o catálogo na página 11
Control units - 12

SCU Control unit Benefits • Compact 6-channel actuator control unit • Single fault safety • Overload and over-temperature protection • Approved for medical applications • Easy to clean • Low standby current • Remote control RS232 Technical data Unit Motor ports (DIN8) Operating device ports (HD15) Battery ports (DSub9) Limit switch ports (HD15) Single fault safety Encoder processing yes/no yes/no Input voltage Frequency Input current (max) Standby power Output voltage Output current (max) Duty cycle: intermittent Duty cycle: short time Ambient temperature Humidity Degree of protection...

Abrir o catálogo na página 12
Control units - 13

38 360 Operating voltage display (LED) Suitable control units and accessories Operating switches Linear actuators Hand switch Foot switch Desk switch Up to 6 connections with DIN8 plug 1. Two connections for HD15 operating devices 2. HD15 limit switch connection 3. Additional space for mounting 4. Data plate software 5. Mains connection

Abrir o catálogo na página 13
Control units - 14

Pinning of HD15 limit switch connection on request (needs a customized SCP) Function Switch 1 Switch 2 Switch 3 Switch 4 24 V DC (com) brown/green red/blue violet red white/yellow, white/green, grey/pink, black Optional external power supply for binary outputs Binary output 1 (22-40 V DC/1 A) Binary output 2 (22-40 V DC/1 A) GND for binary outputs 20-24 V DC, max. 50 mA 5 V DC pulsed GND blue pink grey yellow green brown white Connecting diagram Accessories Plug Mains cable, 3 pole Mains cable, 3 pole Mains cable, 3 pole Mains cable, 3 pole Mains cable, 3 pole Mains cable, 3 pole Battery...

Abrir o catálogo na página 14
Control units - 15

SCU control unit Voltage 1 24 V DC (only for 6-channel version) 5 120 V AC, 60 Hz, class I 9 230 V AC, 50 Hz, class I Number of channels 3 3 channels 6 6 channels Battery 1 None (only for SCU16) 2 Prepared for mounting of battery 3 Under floor 2.7 Ah battery mounted Transformer 0 None (only for SCU16) 3 Standard (AC version) Interface 0 Without RS232 1 With RS232 (only for 6-channel version) SCU parameterization Functionality 11 All channels individually 21 Channel 2+1(+1+1+1) 22 Six (6) channel version 2+2+1+1 Three (3) channel version, all channels 30 synchronously 31 Six (6) channel...

Abrir o catálogo na página 15
Control units - 16

MCU Control unit Benefits • Suitable for mobile applications • LED indication for battery charge level • Audible signal for low charge condition Technical data Unit Motor ports Operating device ports Battery ports Limit switch ports Single fault safety Encoder processing yes/no yes/no Input voltage Frequency Input current (max) Standby power Output voltage Output current (max) Duty cycle: intermittent Duty cycle: short time Ambient temperature Humidity Degree of protection Approvals

Abrir o catálogo na página 16

Todos os catálogos e folhetos técnicos EWELLIX

  1. LIFTKIT-OM

    8 Páginas

  2. SLIDEKIT 2.0

    12 Páginas

  3. LIFTKIT-0S

    8 Páginas

  4. LIFTKIT-TM

    8 Páginas

  5. Ball Screws

    4 Páginas

  6. THG

    6 Páginas

  7. SVC 8x1R 62/62 G3

    3 Páginas

  8. CPMA

    10 Páginas

  9. CPMB

    10 Páginas

  10. LLU catalogue

    74 Páginas

  11. Operating switches

    28 Páginas

  12. Servo pillar CPSM

    10 Páginas

  13. ewellix brochure

    5 Páginas