Levelflex M FMP40
1 / 72Páginas

Excertos do catálogo

Levelflex M FMP40 - 1

Level Pressure Flow Temperature Liquid Registration Systems Services Solutions Analysis Components Technical Information Guided Level Radar Continuous Level Transmitter for - Level Measurement in Bulk Solids and Liquids - Interface Measurement in Liquids Rod probe Coax probe Rope probe Level measurement Continuous level measurement of powdery to granular bulk solids e.g. plastic granulate and liquids. ■ Measurement independent of density or bulk weight, conductivity, dielectric constant, temperature and dust e.g. during pneumatic filling. ■ Measurement is also possible in the event of foam or if the surface is very turbulent. FOUNDATION Fieldbus protocols are available for system integration. ■ Application in safety related systems (overspill protection) with requirements for functional safety up Interface measurement Continuous measurement of interfaces between two liquids with very different dielectric constants, such as in the case of oil and water for example. ■ Measurement independent of density, conductivity ■ Electronics version for the simultaneous measurement of the level of interfaces and the total level in liquids. The HART with 4 to 20 mA analog protocol is available for system integration ■ Special version for the measurement of the level of interfaces at a constant total level. The PROFIBUS PA and FOUNDATION Fieldbus protocols are available Your benefits Probes are available with threaded process connections from %" and flanges from DN40 (1V2"). ■ Rope probes, above all for measurement in bulk solids, ■ Rod probes, above all for liquids ■ Coax probes, for liquids ■ Simple, menu-guided onsite operation with four-line plain text display. ■ Onsite envelope curve on the display for easy ■ Easy remote operation, diagnosis and measuring point documentation with the free operating program ■ Optional remote display and operation. ■ With coax probes the measurement is independent of internals in the tank and of the installation in the ■ Probe rod and probe rope can be replaced/shortened. ■ Approvals: ATEX, FM, CSA, TIIS, NEPSI, IECEx. People for Process Automation

Abrir o catálogo na página 1
Levelflex M FMP40 - 2

Levelflex M FMP40 Table of contents Function and system design. . . . . . . . . . . . . . . . . . . . . 4 Measuring principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Measuring system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Measured variable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Measuring range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Blocking distance . . . . . . . . . . ....

Abrir o catálogo na página 2
Levelflex M FMP40 - 3

Levelflex M FMP40 Commubox FXA195 HART . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commubox FXA291 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ToF adapter FXA291 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Screw in flange FAX50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Extension rod (Centering) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mounting-kit isolated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 66 66 66 67 68 Additional documentation . . . . . . . . . . . . . . . . ....

Abrir o catálogo na página 3
Levelflex M FMP40 - 4

Levelflex M FMP40 Function and system design Measuring principle The Levelflex is a "downward-looking" measuring system that functions according to the ToF method (ToF = Time of Flight). The distance from the reference point (process connection of the measuring device, → ä 43) to the product surface is measured. High-frequency pulses are injected to a probe and led along the probe. The pulses are reflected by the product surface, received by the electronic evaluation unit and converted into level information. This method is also known as TDR (Time Domain Reflectometry). flange: reference...

Abrir o catálogo na página 4
Levelflex M FMP40 - 5

Levelflex M FMP40 Interface measurement When the high-frequency pulses hit the surface of the medium, only a percentage of the transmission pulse is reflected. In the case of media with a low DC1, in particular, the other part penetrates the medium. The pulse is reflected once more at the interface point to a second medium with a higher DC2. The distance to the interface layer now can also be determined taking into account the delayed time-of-flight of the pulse through the upper medium. c = c0 = 300 000 km/s total level DK1 C1 = C0 DK1 interface level DK2 L00-FMP4xxxx-15-00-00-en-007...

Abrir o catálogo na página 5
Levelflex M FMP40 - 6

Measuring system Probe selection The various types of probe in combination with the process connections are suitable for the following Probes with 1 Vz" threaded connection or flange 2) Greater lengths available on request. 3) Max. load of silo ceiling. If overloaded, the rope tears; the bushing remains air-tight.

Abrir o catálogo na página 6
Levelflex M FMP40 - 7

Levelflex M FMP40 Probes with ¾" threaded connection Type of probe: 4 mm rope probe 6 mm rod probe Coax probe 35 m 1) 2m 4m • Liquids measuring range > 4 m • Liquids • Interface measurement • Liquids • Interface measurement not relevant 4 Nm 60 Nm 5 kN 12 kN not relevant not relevant Max. probe length: For application: Sideways capacity: Tensile loading capacity (min.): rupture load (max.): 2) Feature 30 Option "A" Option "P" Option "L" 1) Greater lengths available on request. 2) Max. load of silo ceiling. If overloaded, the rope tears; the bushing remains air-tight. Stand-alone • Power...

Abrir o catálogo na página 7
Levelflex M FMP40 - 8

Levelflex M FMP40 System integration via PROFIBUS PA Maximum 32 transmitters (depending on the segment coupler, 10 in the Ex ia IIC hazardous area according to the FISCO Model) can be connected to the bus. The Bus voltage is supplied by the segment coupler. Both onsite as well as remote operation are possible. personal computer with FieldCare and Profibard resp. Proficard PLC segment coupler PROFIBUS DP ENDRESS + HAUSER PROFIBUS PA T More Functions (valves etc) operating and display module ENDRESS + HAUSER % – + Commubox FXA291 with ToF Adapter FXA291 E FieldCare Prosonic M Micropilot M...

Abrir o catálogo na página 8

Todos os catálogos e folhetos técnicos Endress+Hauser AG

  1. FTL41

    3 Páginas

  2. FTL51B

    6 Páginas

  3. FMG50

    10 Páginas

  4. PTP31B

    3 Páginas

  5. CUS71D

    3 Páginas

  6. iTEMP TMT162

    3 Páginas

  7. CLS54D

    3 Páginas

  8. CLS50D

    3 Páginas

  9. FMX21

    5 Páginas

  10. Liquipoint FTW23

    3 Páginas

  11. Deltapilot FMB50

    7 Páginas

  12. iTHERM TM401

    3 Páginas

  13. COS61D

    3 Páginas

  14. Liquiphant FTL51

    6 Páginas

  15. FMD72

    5 Páginas

  16. PMP51

    7 Páginas

  17. Cerabar PMC51

    7 Páginas

  18. Cerabar PMP75

    8 Páginas

  19. FMD78

    8 Páginas

  20. PMD75

    10 Páginas

  21. FMI51

    4 Páginas

  22. FMU30

    7 Páginas

  23. FMP57

    4 Páginas

  24. FMP55

    4 Páginas

  25. FMP54

    5 Páginas

  26. FMP51

    5 Páginas

  27. FMP50

    4 Páginas

  28. FMR52

    4 Páginas

  29. FMR51

    5 Páginas

  30. F 200

    13 Páginas

  31. D 200

    12 Páginas

  32. E 100

    5 Páginas

  33. C 200

    11 Páginas

  34. B_unit4_1

    1 Páginas

  35. B_unit3_3

    1 Páginas

  36. B_unit3_2

    1 Páginas

  37. Wort cooler

    1 Páginas

  38. Liquiphant T FTL20

    20 Páginas

  39. Gammapilot M FMG60

    48 Páginas

  40. Deltabar S PMD70

    96 Páginas

  41. Deltapilot S FMB70

    56 Páginas

  42. Liquicap T FMI21

    40 Páginas

  43. Prosonic S FDU91

    40 Páginas

  44. Micropilot FMR50

    76 Páginas

Catálogos arquivados

  1. System components

    20 Páginas

  2. Flow Measurement

    32 Páginas