Excertos do catálogo

Product Data Sheet Ultraviolet and Infrared Sensors for Hydrogen & Silane Flame Net Safety’s Hydrogen flame detectors are specially tuned for non-hydrocarbon based flame applications where accurate and instant detection of difficult to see hydrogen and silane flame is required. Our advanced optical sensors ensure the greatest degree of UV and IR spectral bandwave matching to the radiant energy emitted by invisible hydrogen and silane flame — and the lowest degree of matching to non-fire stimuli. This provides ultra-fast alarm, an unparalleled level of false alarm immunity, as well as a field-of-view unmatched in the industry — a full 120° horizontal degrees! Two Radiation Wavelengths Necessary For Alarm— Minimize False Alarm Events (UV/IR-H2 only) Extremely Low Power Consumption Increases Uptime and Lowers Overall Costs Wide Voltage Range Allows For Greater Stability and System Compatibility Manual and Automatic Testing of Optical Surfaces — Constatly Monitors Internal Electronics Wide Area Coverage, Extended Range with Fast Response Times Designed for Extreme Conditions, Operational From -50°C — +75°C Analog, Relay, and HART® Outputs Available Global Certifications and Approvals Enclosed in a rugged, explosion-proof housing, the UVS-H2 and UV/IRS-H2 are engineered for extreme applications and utilize the latest in SMART microprocessor sensor technology. They’re capable of stand-alone operation or can be connected to a variety of control devices to create a dependable fire monitoring system. The field user can define sensitivity and time delay settings to further enhance false-alarm immunity and the built-in testing routines ensure continuous operation. The UVS-H2 and UV/IRS-H2 are ideally suited for specialized applications where response time and a wide field-of-view are most critical — industrial and commercial locations that utilize PMS - Uncoated Field-selectable Sensitivity and Delay Settings Allows Operators To Fine Tune At Installation Site Year Warranty Electronics / 2 Years on Sensors 3 hydrogen fuel cells, hydrogen gas generators, hydrogen refilling stations, and storage tanks as well as semiconductor facilities where silane combustion risks are commonly present. Net Safety’s UVS-H2 and UV/IRS-H2 flame detectors are globally certified for hazardous locations to CSA, ANSI-UL/ISA, and ATEX technical and safety standards. Net Safety has engineered superior UV/IR-H2 and UV-H2 flame detectors specially tuned to detect invisible H2 and Silane flame that are also simple to operate and maintain while delivering all the security and performance required for high-risk, industrial installations!
Abrir o catálogo na página 1
Product Data Sheet UV/IRS-H2 Flame Detector Specifications “SMART” Gas Detector Series ANALOG Power Consumption at 24 Vdc *with Heater Power Consumption at 32 Vdc *with Heater Operating Voltage Range Temperature Range 120 degrees horizontal / 95 degrees vertical Spectral Range UV Radiation 185 to 260 nanometres (1850 to 2600 angstroms) | IR Radiation in the 3.09 micron range Dip switch selectable to 0, 3, 5, 7 seconds Time Delay Sensitivity Settings DIP switch selectable to 8, 16, 24 or 32 counts per second Response Time <6 seconds [ depending on fuel source, fire size and distance ]...
Abrir o catálogo na página 2
Product Data Sheet Specifications con’t - Termination Boxes - Accessories Field of View at Indicated Distance in Feet for n-Heptane Example Field of View - Hydrogen 24” plume - indicated in feet - consult factory for other flame types Fire Size Typical Response Immunity False Alarm Stimuli Stimuli Immunity Range Direct/Indirect Sunlight Halogen, Incandescent Light Florescent Light TERMINATION BOXES Class 1, Division 1, Groups BCD - Class 1, Zone 1 -- Enclosure rated NEMA 4X, IP67 (See man-0081 for full specifications) JB-MPS-A/S Termination box - Analog Output - Switch (for remote MVI...
Abrir o catálogo na página 3
Product Data Sheet UVS-H2 Flame Detector Specifications “SMART” Gas Detector Series ANALOG Operating Voltage Range Temperature Range 120 degrees horizontal / 95 degrees vertical Spectral Range UV Radiation 185 to 260 nanometres (1850 to 2600 angstroms) Time Delay DIP switch selectable to 0, 3, 5, 7 seconds Sensitivity Settings DIP switch selectable to 8, 16, 24 or 32 counts per second Response Time <6 seconds [ depending on fuel source, fire size and distance ] Enclosure Material Red powdercoat with clear anodizing, copper-free aluminum (optional stainless steel), factory sealed housing...
Abrir o catálogo na página 4
Product Data Sheet Specifications con’t - Termination Boxes - Accessories Field of View at Indicated Distance in Feet for n-Heptane Example Field of View - Hydrogen 32” plume - indicated in feet - consult factory for other flame types Fire Size Typical Response Immunity False Alarm Stimuli Stimuli Immunity Range Direct/Indirect Sunlight Halogen, Incandescent Light Florescent Light TERMINATION BOXES Class 1, Division 1, Groups BCD - Class 1, Zone 1 -- Enclosure rated NEMA 4X, IP67 (See man-0081 for full specifications) JB-MPS-A/S Termination box - Analog Output - Switch (for remote MVI...
Abrir o catálogo na página 5
Product Data Sheet Emerson Process Management Calgary, Alberta, Canada T1Y7J7 TWEETS GROUP VIDEO BLOG LIKE SHARE ©2012 Emerson Process Management. All rights reserved. Emerson Process Management, Rosemount Analytical, and Net Safety Monitoring are marks of Emerson Process Management group of companies. All other marks are the property of their respective owners. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the...
Abrir o catálogo na página 6Todos os catálogos e folhetos técnicos Emerson Automation Solutions - ROSEMOUNT
-
VPS 53 Vapor Pressure Sensor
2 Páginas
-
ROSEMOUNT 3051 PRESSURE PRODUCTS
2 Páginas
-
EasyHeat™ XD Cable Kits
2 Páginas
-
FRL Accessories
14 Páginas
-
TankRadar Pro
32 Páginas
-
Rosemount™ 2140 Level Detector
22 Páginas
-
Roxar subsea SenCorr PTPT sensor 10K
2 Páginas
-
Roxar subsea PIG
2 Páginas
-
Roxar subsea SenCorr PTPT sensor 15K
2 Páginas
-
Roxar subsea Sand monitor
2 Páginas
-
Roxar subsea CM10K
2 Páginas
-
Roxar PTPT15K
2 Páginas
-
Rosemount TankRadar OFC
2 Páginas
-
Rosemount™ 2140:SIS Level Detector
22 Páginas
-
Rosemount 5708 Series 3D Solids Scanner
30 Páginas
-
SW-300
4 Páginas
-
DL8000
12 Páginas
-
Rosemount™ 8800D Series Vortex Flowmeter
82 Páginas
-
Rosemount™ 3144P Temperature Transmitter
82 Páginas
-
Rosemount™ 3051 Pressure Transmitter
82 Páginas
-
DeltaV Analyze
8 Páginas
-
Fisher 657 and 667 Diaphragm Actuators
16 Páginas
-
DeltaV SIS with Electronic Marshalling
48 Páginas
-
AMS Machine Works
4 Páginas
-
Emerson Smart Wireless Gateway
4 Páginas
-
DeltaV Executive Portal
7 Páginas
-
Fisher 646 Electro-Pneumatic Transducer
20 Páginas
-
1500XA Gas Chromatograph
8 Páginas
-
Rosemount 3051S Series of Instrumentation
162 Páginas
-
Rosemount 975UR
4 Páginas
-
Rosemount 975HR
4 Páginas
-
Rosemount 975UF
4 Páginas
-
Rosemount 975MR
4 Páginas
-
CT5400 Process Gas Analyzer
4 Páginas
-
CT5200 Industrial Gas Analyzer
4 Páginas
-
CT2211 Leak Detection System
4 Páginas
-
OPM 4001 Opacity/Dust Density Monitor
12 Páginas
-
6888 In Situ Flue Gas Oxygen Transmitter
16 Páginas
-
Combustion Analysis Solutions
6 Páginas
-
X-STREAM X2GK - Compact Gas Analyzer
8 Páginas
-
Process Gas Analysis Solutions
8 Páginas
-
On-line Gas Analysis in Urea Plants
2 Páginas
-
Lye Peeling of Fruits and Vegetables
2 Páginas
-
Leak Detection Using Conductivity
3 Páginas
-
Improve Copper Yield in Flotation
2 Páginas
-
Desalination of Seawater
2 Páginas
-
Conductivity Measurements in Brewing
2 Páginas
-
Chemical Concentration Control
2 Páginas
-
700XA Process Gas Chromatograph
12 Páginas
-
Fixed Gas Detector Calibration Kits
2 Páginas
-
MT Ultrasonic Portable Mapping Tool
2 Páginas
-
Incus Ultrasonic Gas Leak Detector
6 Páginas
-
01-TT Ultrasonic Portable Test Tool
2 Páginas
-
SafeGuard Alarm Controller
2 Páginas
-
Safety Monitoring
6 Páginas
-
Advanced Power Analytical Solutions
8 Páginas
-
AMS Suite
16 Páginas
-
Drinking Water Sht 2V2
2 Páginas
-
Liquid Analysis for Metal Extraction
12 Páginas
-
Line Card
2 Páginas
-
Installation & Calibration Equipment
48 Páginas
-
Drinking Water Industry
16 Páginas
-
SafeGuard 16 Channel Controller
2 Páginas
-
Explosion Proof Motion Detector
2 Páginas
-
Explosion Proof Video Camera
2 Páginas
-
Phoenix Triple IR Flame Detector
4 Páginas
-
Net Safety UV/IR Flame Detector
4 Páginas
-
Net Safety UV Flame Detector
4 Páginas
-
Millennium II BASIC Gas Detector
4 Páginas
-
Millennium Toxic Gas Detector
2 Páginas
Catálogos arquivados
-
UV/IRS Flame Detector
4 Páginas
-
UVS Flame Detector
4 Páginas