
Excertos do catálogo

Food & Beverage Application Data Sheet Lye Peeling of Fruits and Vegetables Background Many fruits and vegetables are prepared for peeling and canning by exposure to caustic (NaOH). To ensure adequate and consistent peeling, the concentration of caustic in the treatment bath must be maintained at an effective strength. At the same time, if the caustic bath is too strong the fruit or vegetable can be damaged. Process The typical process consists of an open tank of caustic heated to 170–220 °F (76–105 °C) by live steam. The target caustic concentration can vary from 3 to 15 %. Exposure time for the product is usually 5 minutes or less, after which the product is placed on moving grates and washed by high pressure nozzles to remove entrained caustic. A significant amount of caustic is carried out by the product, so the bath must be continually replenished to maintain an adequate volume of caustic solution and a caustic concentration at the target value. This could involve addition of water, based on level control, as well as makeup caustic, based on the conductivity measurement. The best place to start is to look at how the bath behaves and how concentration is maintained manually. Since the background increase cannot be distinguished from the conductivity due to the caustic, the conductivity set point (or calibration curve for a concentration measurement) may need to change as the bath ages. This effect will be smaller for higher caustic concentrations and for shorter intervals between bath replacement. Concentration Measurement In general, when there is background conductivity, the conductivity versus concentration curve will not be the same as the standard curve for caustic (NaOH) in distilled water, due to buildup of salts in the bath. The curve must be developed from operating data, i.e. conductivity and titrated caustic concentrations. Data should be taken over the life of at least three (3) baths; the age of the bath and any additions to the bath should be noted, in addition to the conductivity and titrated caustic concentration. Once a curve has been developed, the on-line measurement can usually be corrected for salt build-up by standardization following a routine laboratory titration. Important Considerations The Measurement Due to its resistance to fouling, toroidal conductivity is the best measurement technique here. The conductivity sensor is typically mounted in the holding tank (Figure 1). Relatively clean processes may use the 228 sensor, but applications with potential for heavy coating should use the large bore 226 sensor. As the bath ages, there is a buildup of salts, which are leached out of the peels and carried in with dirt and other suspended contaminants. This buildup causes an increase in the background conductivity. Select the toroidal conductivity sensor based on how heavily the bath is loaded with suspended solids. When evaluating how to control bath concentration and volume, how the bath behaves and how it is manually controlled should be thoroughly examined. When setting up a concentration measurement, data should be taken over the life of three (3) baths to determine the relationship between conductivity and concentration.
Abrir o catálogo na página 1
Food & Beverages Instrumentation 226 and 228 Toroidal Conductivity Sensors 1066 Toroidal Conductivity Analyzer Toroidal (inductive) principle of measurement and construction Chemically-resistant materials of construction 4–20 mA output with superimposed HART® or FOUNDATION™ Fieldbus communications protocol Clear, Large, easy-to-read display Customizable percent concentration curve Automatic/manual temperature compensation ensures accurate monitoring and control Figure 1 - Lye Peeling of Fruits and Vegetables Fruit or Vegetables Washers Holding Tank www.RosemountAnalytical.com...
Abrir o catálogo na página 2Todos os catálogos e folhetos técnicos Emerson Automation Solutions - ROSEMOUNT
-
VPS 53 Vapor Pressure Sensor
2 Páginas
-
ROSEMOUNT 3051 PRESSURE PRODUCTS
2 Páginas
-
EasyHeat™ XD Cable Kits
2 Páginas
-
FRL Accessories
14 Páginas
-
TankRadar Pro
32 Páginas
-
Rosemount™ 2140 Level Detector
22 Páginas
-
Roxar subsea SenCorr PTPT sensor 10K
2 Páginas
-
Roxar subsea PIG
2 Páginas
-
Roxar subsea SenCorr PTPT sensor 15K
2 Páginas
-
Roxar subsea Sand monitor
2 Páginas
-
Roxar subsea CM10K
2 Páginas
-
Roxar PTPT15K
2 Páginas
-
Rosemount TankRadar OFC
2 Páginas
-
Rosemount™ 2140:SIS Level Detector
22 Páginas
-
Rosemount 5708 Series 3D Solids Scanner
30 Páginas
-
SW-300
4 Páginas
-
DL8000
12 Páginas
-
Rosemount™ 8800D Series Vortex Flowmeter
82 Páginas
-
Rosemount™ 3144P Temperature Transmitter
82 Páginas
-
Rosemount™ 3051 Pressure Transmitter
82 Páginas
-
DeltaV Analyze
8 Páginas
-
Fisher 657 and 667 Diaphragm Actuators
16 Páginas
-
DeltaV SIS with Electronic Marshalling
48 Páginas
-
AMS Machine Works
4 Páginas
-
Emerson Smart Wireless Gateway
4 Páginas
-
DeltaV Executive Portal
7 Páginas
-
Fisher 646 Electro-Pneumatic Transducer
20 Páginas
-
1500XA Gas Chromatograph
8 Páginas
-
Rosemount 3051S Series of Instrumentation
162 Páginas
-
Rosemount 975UR
4 Páginas
-
Rosemount 975HR
4 Páginas
-
Rosemount 975UF
4 Páginas
-
Rosemount 975MR
4 Páginas
-
CT5400 Process Gas Analyzer
4 Páginas
-
CT5200 Industrial Gas Analyzer
4 Páginas
-
CT2211 Leak Detection System
4 Páginas
-
OPM 4001 Opacity/Dust Density Monitor
12 Páginas
-
6888 In Situ Flue Gas Oxygen Transmitter
16 Páginas
-
Combustion Analysis Solutions
6 Páginas
-
X-STREAM X2GK - Compact Gas Analyzer
8 Páginas
-
Process Gas Analysis Solutions
8 Páginas
-
On-line Gas Analysis in Urea Plants
2 Páginas
-
Leak Detection Using Conductivity
3 Páginas
-
Improve Copper Yield in Flotation
2 Páginas
-
Desalination of Seawater
2 Páginas
-
Conductivity Measurements in Brewing
2 Páginas
-
Chemical Concentration Control
2 Páginas
-
700XA Process Gas Chromatograph
12 Páginas
-
Fixed Gas Detector Calibration Kits
2 Páginas
-
MT Ultrasonic Portable Mapping Tool
2 Páginas
-
Incus Ultrasonic Gas Leak Detector
6 Páginas
-
01-TT Ultrasonic Portable Test Tool
2 Páginas
-
SafeGuard Alarm Controller
2 Páginas
-
Safety Monitoring
6 Páginas
-
Advanced Power Analytical Solutions
8 Páginas
-
AMS Suite
16 Páginas
-
Drinking Water Sht 2V2
2 Páginas
-
Liquid Analysis for Metal Extraction
12 Páginas
-
Line Card
2 Páginas
-
Installation & Calibration Equipment
48 Páginas
-
Drinking Water Industry
16 Páginas
-
SafeGuard 16 Channel Controller
2 Páginas
-
Explosion Proof Motion Detector
2 Páginas
-
Explosion Proof Video Camera
2 Páginas
-
Phoenix Triple IR Flame Detector
4 Páginas
-
Net Safety UV/IR Flame Detector
4 Páginas
-
Net Safety UV Flame Detector
4 Páginas
-
Millennium II BASIC Gas Detector
4 Páginas
-
Millennium Toxic Gas Detector
2 Páginas
Catálogos arquivados
-
UV/IRS Flame Detector
4 Páginas
-
UVS Flame Detector
4 Páginas
-
UV/IRS-H2 and UVS-H2 Flame Detectors
6 Páginas