Excertos do catálogo

GDU-Incus Ultrasonic Gas Leak Detector Product Data Sheet GDU-Incus Ultrasonic Gas Leak Detector Wide Area Coverage For Toxic and Combustible Gases “SMART” Gas Detector Series The GDU-Incus is an advanced leak detection system utilizing four ultrasensitive acoustic sensors which constantly monitor wide areas for ultrasound generated from the release of pressurized gas. This advanced gas sensing technology never requires calibration or replacement, for the life of the instrument. Ideally suited for monitoring ventilated outdoor applications, the GDU-Incus has been engineered to withstand even the most extreme conditions. Performance is not affected by inclement weather, wind direction, leak direction or any potential gas dilution, with an instantaneous response to all gas types. Instantaneous Response To All Gas Leaks (LEL or ppm) 4-20 mA Analog, ‘multi-drop’ RS485 Digital Interface, and HART Communication Protocol Certified performance in extreme temperatures Certified Worldwide for Hazardous Locations Automated Electronic Self Test, Failsafe Operation and Maintenance Free Innovative Mapping Tools Helps Operators Achieve Optimum Performance At Site Location Widest Area of Coverage, up to 40 Meter Radius Through Four Independent Sensors Programmable Time Delays to Allow For False Alarm Sources (Pressure Venting, etc) Four Multi-Directional Sensor Heads Sensor Design - They Just Keep Working Quad, independent sensor heads provide the widest overall detection range and reduce the possibility of obstruction, common with a traditional single microphone design. Field-proven Ultrasonic Sensor Principle Each sensor is completely free of moving parts and will not age, will not drift, and will never need replacing under normal working conditions. Maintenance free protection with proven reliability. Advanced acoustic sensors utilize the proven method of ultrasonic gas leak detection to protect your plant and personnel, with hundreds of installations worldwide. Ultrasound is generated from pressurized leaks of any gas type, providing simultaneous flammable and toxic gas coverage. The presence of a concentrated gas cloud for detection is never required, making this technology ideal for wide area coverage in outdoor applications. Continuous Self-test Functionality Ensures Instrument Health Sealed Ceramic Sensor Housing Built for Extreme Conditions Piezo-electric sensor heads are encased in a virtually indestructible ceramic housing and sealed against temperature, moisture, and industrial contaminants. Electronic self-test checks the detector every160ms by sending an amplitude signal through the sensing circuitry. A detailed analysis of the result is then performed by the internal system. Any compromised component or function is instantly identified and a fault signal is communicated back to the control system. Dealing with extreme heat or cold? We’ve got you covered with an operational temperature range of -40°C to +85°C! Corrosion resistant stainless steel housing is standard, and every unit is rated IP66/67.
Abrir o catálogo na página 1
GDU-Incus Ultrasonic Gas Leak Detector Product Data Sheet 15.5M 74DB BACKGROUND NOISE DETECTION ENVELOPE 84DB BACKGROUND NOISE DETECTION ENVELOPE 6.6M Pressurized With a Complete Detection Solution Gas Release Response Levels — Detect • Distinguish • Defend from EMERSON You’re Protected, Even in the Most Extreme Applications. GROUND LEVEL Explosive Cloud 19.5M Formation Toxic Cloud Formation Liquid Accumulation EXPLOSION EVENT CANNOT TRAVEL THROUGH SOLID WALLS AND OBJECTS High Pressure Jet Fire Wide Area Explosive Fire ULTRASONIC DETECTION OVERVIEW WIND DIRECTION Ultrasonic (acoustic) gas...
Abrir o catálogo na página 2
GDU-Incus Ultrasonic Gas Leak Detector Product Data Sheet GDU-Incus Ultrasonic Gas Leak Detector Specifications GDU-INCUS Detection Frequency Range Dynamic Range Area Coverage 2 to 40 meter (6.6 to 131 foot) radius (leak pressure, size and background level dependent) Response Time Instantaneous (<1s - speed of sound) Programmable Alarm Delay End user configurable alarm delay via 1 second variable increments -40°C to +85°C (-40°F to +185°F) Operating Temperatures Operating Humidity Range Continuous electronic check of sensor integrity Auto Test Ingress Protection Rated IP66/67 to withstand...
Abrir o catálogo na página 3
GDU-Incus Ultrasonic Gas Leak Detector HEADQUARTERS: FLAME & GAS DETECTION Emerson Process Management 2721 Hopewell Place NE Calgary, AB, Canada T1Y 7J7 T +1 (403) 219-0688 F +1 (403) 219-0694 www.emersonprocess.com/safety Product Data Sheet September 2013 HEADQUARTERS: ULTRASONIC GAS LEAK DETECTION Emerson Process Management Unit 18, Somerford Business Park, Wilverley Road, Christchurch, Dorset, BH23 3RU, UK T +44 (0) 1202 400630 F +44 (0)1202 496796 www.emersonprocess.com/safety ©2013 Emerson Process Management. All rights reserved. Emerson Process Management are marks of Emerson Process...
Abrir o catálogo na página 4Todos os catálogos e folhetos técnicos Emerson Automation Solutions - ROSEMOUNT
-
VPS 53 Vapor Pressure Sensor
2 Páginas
-
ROSEMOUNT 3051 PRESSURE PRODUCTS
2 Páginas
-
EasyHeat™ XD Cable Kits
2 Páginas
-
FRL Accessories
14 Páginas
-
TankRadar Pro
32 Páginas
-
Rosemount™ 2140 Level Detector
22 Páginas
-
Roxar subsea SenCorr PTPT sensor 10K
2 Páginas
-
Roxar subsea PIG
2 Páginas
-
Roxar subsea SenCorr PTPT sensor 15K
2 Páginas
-
Roxar subsea Sand monitor
2 Páginas
-
Roxar subsea CM10K
2 Páginas
-
Roxar PTPT15K
2 Páginas
-
Rosemount TankRadar OFC
2 Páginas
-
Rosemount™ 2140:SIS Level Detector
22 Páginas
-
Rosemount 5708 Series 3D Solids Scanner
30 Páginas
-
SW-300
4 Páginas
-
DL8000
12 Páginas
-
Rosemount™ 8800D Series Vortex Flowmeter
82 Páginas
-
Rosemount™ 3144P Temperature Transmitter
82 Páginas
-
Rosemount™ 3051 Pressure Transmitter
82 Páginas
-
DeltaV Analyze
8 Páginas
-
Fisher 657 and 667 Diaphragm Actuators
16 Páginas
-
DeltaV SIS with Electronic Marshalling
48 Páginas
-
AMS Machine Works
4 Páginas
-
Emerson Smart Wireless Gateway
4 Páginas
-
DeltaV Executive Portal
7 Páginas
-
Fisher 646 Electro-Pneumatic Transducer
20 Páginas
-
1500XA Gas Chromatograph
8 Páginas
-
Rosemount 3051S Series of Instrumentation
162 Páginas
-
Rosemount 975UR
4 Páginas
-
Rosemount 975HR
4 Páginas
-
Rosemount 975UF
4 Páginas
-
Rosemount 975MR
4 Páginas
-
CT5400 Process Gas Analyzer
4 Páginas
-
CT5200 Industrial Gas Analyzer
4 Páginas
-
CT2211 Leak Detection System
4 Páginas
-
OPM 4001 Opacity/Dust Density Monitor
12 Páginas
-
6888 In Situ Flue Gas Oxygen Transmitter
16 Páginas
-
Combustion Analysis Solutions
6 Páginas
-
X-STREAM X2GK - Compact Gas Analyzer
8 Páginas
-
Process Gas Analysis Solutions
8 Páginas
-
On-line Gas Analysis in Urea Plants
2 Páginas
-
Lye Peeling of Fruits and Vegetables
2 Páginas
-
Leak Detection Using Conductivity
3 Páginas
-
Improve Copper Yield in Flotation
2 Páginas
-
Desalination of Seawater
2 Páginas
-
Conductivity Measurements in Brewing
2 Páginas
-
Chemical Concentration Control
2 Páginas
-
700XA Process Gas Chromatograph
12 Páginas
-
Fixed Gas Detector Calibration Kits
2 Páginas
-
MT Ultrasonic Portable Mapping Tool
2 Páginas
-
Incus Ultrasonic Gas Leak Detector
6 Páginas
-
01-TT Ultrasonic Portable Test Tool
2 Páginas
-
SafeGuard Alarm Controller
2 Páginas
-
Safety Monitoring
6 Páginas
-
Advanced Power Analytical Solutions
8 Páginas
-
AMS Suite
16 Páginas
-
Drinking Water Sht 2V2
2 Páginas
-
Liquid Analysis for Metal Extraction
12 Páginas
-
Line Card
2 Páginas
-
Installation & Calibration Equipment
48 Páginas
-
Drinking Water Industry
16 Páginas
-
SafeGuard 16 Channel Controller
2 Páginas
-
Explosion Proof Motion Detector
2 Páginas
-
Explosion Proof Video Camera
2 Páginas
-
Phoenix Triple IR Flame Detector
4 Páginas
-
Net Safety UV/IR Flame Detector
4 Páginas
-
Net Safety UV Flame Detector
4 Páginas
-
Millennium II BASIC Gas Detector
4 Páginas
-
Millennium Toxic Gas Detector
2 Páginas
Catálogos arquivados
-
UV/IRS Flame Detector
4 Páginas
-
UVS Flame Detector
4 Páginas
-
UV/IRS-H2 and UVS-H2 Flame Detectors
6 Páginas