Excertos do catálogo

Product Data Sheet CT5200 Industrial Gas Analyzer Cascade’s Industrial gas analyzers implement a hybrid multicomponent system (QCL and TDL), the system’s interchangeable modular configuration will allow for up to nine lasers to detect up to 20 gases in a variety of industrial and harsh environments. The Industrial Gas Analyzers embedded ARM processor enables the system to fully operate autonomously and it's automated verification and health diagnostics reporting ensures smooth-running in hazardous and critical applications that necessitate high operational reliability. CT5200 Industrial Gas Analyzer The worlds first hybrid Multicomponent QCL, TDL analyzer JJ "True multicomponent" analyzer – up to 20 gases JJ All solid state, no moving parts JJ Low maintenance and low lifetime cost JJ Embedded ARM processor for fully autonomous operation JJ No calibration required JJ Continuous health diagnostic reporting JJ Intuitive simple front panel user interface allows access to all instrument functions JJ “At sensor” data download capability for offline analysis Field serviceable and field configurable JJ Interchangeable modular configuration for up to 9 lasers Hazardous certification available JJ Europe, ATEX II 2 G, groups IIC JJ North America, Class I Division 2, groups A, B, C, D Designed and rated for outdoor use JJ No need to use valuable shelter real estate Mounting options JJ Available in wall mount and rack mount configurations Applications JJ Petrochemical process monitoring JJ Ethylene/propylene product impurities JJ Natural/shale gas JJ Process analytics in hazardous environments JJ Continuous Emissions Monitoring (CEMs) JJ Other applications available on request
Abrir o catálogo na página 1
Specifications Table 1 - CT5200 Industrial Gas Analyzer Specifications Value Application Measurement technique Laser classification CLASS 1 BS EN 60825-1:2007 Safety of laser products Equipment classification and requirements (identical to IEC 60825-1 2007) Performance Repeatability Measurement rate Environmental Temperature range Sample gas temperature range Humidity range Protection class Hazardous area classification Inputs and Outputs Analogue signal out 6 x 4–20 mA measurement output (option) 4 x 4–20 mA signal input (option) 3 x normally closed contact fault relay outputs Modbus TCP,...
Abrir o catálogo na página 2
Table 2 - Measurement Performance Other gases and ranges are available on request. The ranges and detection limits provided indicate typical analyzer performance but may change depending on your application. Please contact Rosemount Analytical for more information.
Abrir o catálogo na página 3
Product Data Sheet Recommended Installation The drawings below represent the minimum recommended installation guidelines for the CT5200 Industrial Gas Analyzer. Please consult Rosemount Analytical for detailed installation recommendation of your application. Figure 1 - CT5200 Industrial Gas Analyzer www.RosemountAnalytical.com www.analyticexpert.com ©2015 Emerson Process Management. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their respective owners. HEADQUARTERS Emerson Process Management Glendevon House...
Abrir o catálogo na página 4Todos os catálogos e folhetos técnicos Emerson Automation Solutions - ROSEMOUNT
-
VPS 53 Vapor Pressure Sensor
2 Páginas
-
ROSEMOUNT 3051 PRESSURE PRODUCTS
2 Páginas
-
EasyHeat™ XD Cable Kits
2 Páginas
-
FRL Accessories
14 Páginas
-
TankRadar Pro
32 Páginas
-
Rosemount™ 2140 Level Detector
22 Páginas
-
Roxar subsea SenCorr PTPT sensor 10K
2 Páginas
-
Roxar subsea PIG
2 Páginas
-
Roxar subsea SenCorr PTPT sensor 15K
2 Páginas
-
Roxar subsea Sand monitor
2 Páginas
-
Roxar subsea CM10K
2 Páginas
-
Roxar PTPT15K
2 Páginas
-
Rosemount TankRadar OFC
2 Páginas
-
Rosemount™ 2140:SIS Level Detector
22 Páginas
-
Rosemount 5708 Series 3D Solids Scanner
30 Páginas
-
SW-300
4 Páginas
-
DL8000
12 Páginas
-
Rosemount™ 8800D Series Vortex Flowmeter
82 Páginas
-
Rosemount™ 3144P Temperature Transmitter
82 Páginas
-
Rosemount™ 3051 Pressure Transmitter
82 Páginas
-
DeltaV Analyze
8 Páginas
-
Fisher 657 and 667 Diaphragm Actuators
16 Páginas
-
DeltaV SIS with Electronic Marshalling
48 Páginas
-
AMS Machine Works
4 Páginas
-
Emerson Smart Wireless Gateway
4 Páginas
-
DeltaV Executive Portal
7 Páginas
-
Fisher 646 Electro-Pneumatic Transducer
20 Páginas
-
1500XA Gas Chromatograph
8 Páginas
-
Rosemount 3051S Series of Instrumentation
162 Páginas
-
Rosemount 975UR
4 Páginas
-
Rosemount 975HR
4 Páginas
-
Rosemount 975UF
4 Páginas
-
Rosemount 975MR
4 Páginas
-
CT5400 Process Gas Analyzer
4 Páginas
-
CT2211 Leak Detection System
4 Páginas
-
OPM 4001 Opacity/Dust Density Monitor
12 Páginas
-
6888 In Situ Flue Gas Oxygen Transmitter
16 Páginas
-
Combustion Analysis Solutions
6 Páginas
-
X-STREAM X2GK - Compact Gas Analyzer
8 Páginas
-
Process Gas Analysis Solutions
8 Páginas
-
On-line Gas Analysis in Urea Plants
2 Páginas
-
Lye Peeling of Fruits and Vegetables
2 Páginas
-
Leak Detection Using Conductivity
3 Páginas
-
Improve Copper Yield in Flotation
2 Páginas
-
Desalination of Seawater
2 Páginas
-
Conductivity Measurements in Brewing
2 Páginas
-
Chemical Concentration Control
2 Páginas
-
700XA Process Gas Chromatograph
12 Páginas
-
Fixed Gas Detector Calibration Kits
2 Páginas
-
MT Ultrasonic Portable Mapping Tool
2 Páginas
-
Incus Ultrasonic Gas Leak Detector
6 Páginas
-
01-TT Ultrasonic Portable Test Tool
2 Páginas
-
SafeGuard Alarm Controller
2 Páginas
-
Safety Monitoring
6 Páginas
-
Advanced Power Analytical Solutions
8 Páginas
-
AMS Suite
16 Páginas
-
Drinking Water Sht 2V2
2 Páginas
-
Liquid Analysis for Metal Extraction
12 Páginas
-
Line Card
2 Páginas
-
Installation & Calibration Equipment
48 Páginas
-
Drinking Water Industry
16 Páginas
-
SafeGuard 16 Channel Controller
2 Páginas
-
Explosion Proof Motion Detector
2 Páginas
-
Explosion Proof Video Camera
2 Páginas
-
Phoenix Triple IR Flame Detector
4 Páginas
-
Net Safety UV/IR Flame Detector
4 Páginas
-
Net Safety UV Flame Detector
4 Páginas
-
Millennium II BASIC Gas Detector
4 Páginas
-
Millennium Toxic Gas Detector
2 Páginas
Catálogos arquivados
-
UV/IRS Flame Detector
4 Páginas
-
UVS Flame Detector
4 Páginas
-
UV/IRS-H2 and UVS-H2 Flame Detectors
6 Páginas