Excertos do catálogo

CT2211 Leak Detection System Product Data Sheet Leak Detection System The European Commission’s Aerosol Dispensers Directive (ADD) legislation (UN ADR 2013, 75/324/EEC) mandates that aerosol dispensers and small receptacles containing compressed gas (gas cartridges) must pass a leak-proof test before they are transported. Aerosol manufacturers have traditionally relied on water bath testing to verify the integrity of aerosol products. This technique, however, is costly, resource intensive and highly disruptive to production.[1] Cascade’s CT2211 leak detection system detects and rejects leaking aerosol cans up to a rate of 500 cans per minute. The system is contactless, ensuring minimal product damage or contamination. Its design allows for the detection of a wide range of propellants including LPG, R134a, CO2, N2O, and DME while continuous health monitoring features result in lower maintenance costs and higher operational reliability. With the increasing number of safety and quality standards required, Cascade’s CT2211 will ensure current and future regulatory compliance. Water bath testing alternatives, such as QCL, speed the production process by eliminating the water bath bottleneck and in turn offer reduced floor space utilization and energy consumption leading to higher customer ROI. CT2211 Leak Detection System Instantaneous response JJ High velocity sample delivery JJ 20 millisecond analysis time JJ 500 cans per minute JJ Automated rejection/alarm JJ Continuous health monitoring High sensitivity JJ 2 x 10-3 mbar.L.sec -1 JJ Independently accredited, suitable for waterbath alternative Field serviceable and field configurable JJ Modular design for easy customization JJ Field replaceable parts JJ Low maintenance/zero consumables JJ Automated cell and filter purge Typical applications ATEX certified Other applications available on request JJ Configurable archway samples air from all around the can JJ Leaks detected from all vulnerable points
Abrir o catálogo na página 1
CT2211 Leak Detection System Specifications Table 1 - CT2211 Leak Detection System Specifications Value Application Leak Detection System Measurement technique Quantum Cascade Laser Laser classification CLASS 1 BS EN 60825-1:2007 Safety of laser products Equipment classification and requirements (identical to IEC 60825-1 2007) Performance Sensitivity Line speed Response time Environmental Temperature range Sample gas temperature range Room temperature Humidity range Protection class Hazardous area classification Inputs and Outputs 3 x normally closed contact Inlet gas port connector Exhaust...
Abrir o catálogo na página 2
CT2211 Leak Detection System Table 2 - Configuration Configuration Pedestal Control and Rejection System (out of zone) Out of Zone Status Lamps (Red, Amber and Green) Interface to Customer PLC (240 signals) Production Line Reject Chute Standard Equipment ATEX Zone 2 Leak Detector Wall Mount Control and Rejection System (out of zone) Line Encoder Air Pressure Monitoring Performance Options Project Options Air Mechanical Soft KEY: • Standard, o Option, - n/a Other gases and ranges are available on request. The ranges and detection limits provided indicate typical analyzer performance but may...
Abrir o catálogo na página 3
CT2211 Leak Detection System Product Data Sheet Recommended Installation The drawings below represent the minimum recommended installation guidelines for the CT2211 Leak Detection System. Please consult Rosemount Analytical for detailed installation recommendation of your application. Figure 1 - CT2211 Leak Detection System Emerson Process Management Glendevon House Castle Business Park, FK9 4TZ ©2015 Emerson Process Management. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount Analytical is a mark of Emerson Process Management family of...
Abrir o catálogo na página 4Todos os catálogos e folhetos técnicos Emerson Automation Solutions - ROSEMOUNT
-
VPS 53 Vapor Pressure Sensor
2 Páginas
-
ROSEMOUNT 3051 PRESSURE PRODUCTS
2 Páginas
-
EasyHeat™ XD Cable Kits
2 Páginas
-
FRL Accessories
14 Páginas
-
TankRadar Pro
32 Páginas
-
Rosemount™ 2140 Level Detector
22 Páginas
-
Roxar subsea SenCorr PTPT sensor 10K
2 Páginas
-
Roxar subsea PIG
2 Páginas
-
Roxar subsea SenCorr PTPT sensor 15K
2 Páginas
-
Roxar subsea Sand monitor
2 Páginas
-
Roxar subsea CM10K
2 Páginas
-
Roxar PTPT15K
2 Páginas
-
Rosemount TankRadar OFC
2 Páginas
-
Rosemount™ 2140:SIS Level Detector
22 Páginas
-
Rosemount 5708 Series 3D Solids Scanner
30 Páginas
-
SW-300
4 Páginas
-
DL8000
12 Páginas
-
Rosemount™ 8800D Series Vortex Flowmeter
82 Páginas
-
Rosemount™ 3144P Temperature Transmitter
82 Páginas
-
Rosemount™ 3051 Pressure Transmitter
82 Páginas
-
DeltaV Analyze
8 Páginas
-
Fisher 657 and 667 Diaphragm Actuators
16 Páginas
-
DeltaV SIS with Electronic Marshalling
48 Páginas
-
AMS Machine Works
4 Páginas
-
Emerson Smart Wireless Gateway
4 Páginas
-
DeltaV Executive Portal
7 Páginas
-
Fisher 646 Electro-Pneumatic Transducer
20 Páginas
-
1500XA Gas Chromatograph
8 Páginas
-
Rosemount 3051S Series of Instrumentation
162 Páginas
-
Rosemount 975UR
4 Páginas
-
Rosemount 975HR
4 Páginas
-
Rosemount 975UF
4 Páginas
-
Rosemount 975MR
4 Páginas
-
CT5400 Process Gas Analyzer
4 Páginas
-
CT5200 Industrial Gas Analyzer
4 Páginas
-
OPM 4001 Opacity/Dust Density Monitor
12 Páginas
-
6888 In Situ Flue Gas Oxygen Transmitter
16 Páginas
-
Combustion Analysis Solutions
6 Páginas
-
X-STREAM X2GK - Compact Gas Analyzer
8 Páginas
-
Process Gas Analysis Solutions
8 Páginas
-
On-line Gas Analysis in Urea Plants
2 Páginas
-
Lye Peeling of Fruits and Vegetables
2 Páginas
-
Leak Detection Using Conductivity
3 Páginas
-
Improve Copper Yield in Flotation
2 Páginas
-
Desalination of Seawater
2 Páginas
-
Conductivity Measurements in Brewing
2 Páginas
-
Chemical Concentration Control
2 Páginas
-
700XA Process Gas Chromatograph
12 Páginas
-
Fixed Gas Detector Calibration Kits
2 Páginas
-
MT Ultrasonic Portable Mapping Tool
2 Páginas
-
Incus Ultrasonic Gas Leak Detector
6 Páginas
-
01-TT Ultrasonic Portable Test Tool
2 Páginas
-
SafeGuard Alarm Controller
2 Páginas
-
Safety Monitoring
6 Páginas
-
Advanced Power Analytical Solutions
8 Páginas
-
AMS Suite
16 Páginas
-
Drinking Water Sht 2V2
2 Páginas
-
Liquid Analysis for Metal Extraction
12 Páginas
-
Line Card
2 Páginas
-
Installation & Calibration Equipment
48 Páginas
-
Drinking Water Industry
16 Páginas
-
SafeGuard 16 Channel Controller
2 Páginas
-
Explosion Proof Motion Detector
2 Páginas
-
Explosion Proof Video Camera
2 Páginas
-
Phoenix Triple IR Flame Detector
4 Páginas
-
Net Safety UV/IR Flame Detector
4 Páginas
-
Net Safety UV Flame Detector
4 Páginas
-
Millennium II BASIC Gas Detector
4 Páginas
-
Millennium Toxic Gas Detector
2 Páginas
Catálogos arquivados
-
UV/IRS Flame Detector
4 Páginas
-
UVS Flame Detector
4 Páginas
-
UV/IRS-H2 and UVS-H2 Flame Detectors
6 Páginas