
Excertos do catálogo

Application Data Sheet Chemical Concentration Control Background Numerous industrial applications require solutions of a specific chemical strength. Such specific concentrations are achieved by mixing a full strength solution with water in the desired proportions. Flow-paced control is used as a crude control in this operation, and a conductivity measurement is used for trim control. Controlling Concentration The full-strength solution and water are mixed in two stages illustrated in Figure 1: 1. A flow ratio controller on a mixing tank is set for a given flow rate of the full strength solution and a proportional flow rate of the water. The flow-ratio controller is set to produce a concentration slightly weaker than that which is desired. The flow-ratio controller should also be capable of warning operators when no liquid is actually flowing in the full strength solution and the water lines. 2. A control valve receiving input from a conductivity analyzer functions as a “trim control”. It adds a small amount of full strength solution to the mixing tank to produce the exact concentration desired. For example, in making a 35 % caustic solution from a large bulk caustic supply at 50 %, the flow ratio controller is adjusted to make a 30 % solution and the conductivity signal is used to add additional caustic to make the 35 % solution. Conductivity is an economical and widely used index of concentration for most acid, base, and salt solutions. It is important to determine the range of possible concentrations at a given location in order to interpret conductivity measurements. A good conductivity application will have a significant change in reading over the possible concentration range and only one concentration value for any given conductivity reading. Conductivity tends to increase with concentration for dilute solutions, however concentrated solutions can have very different properties. Caustic (NaOH) is an example in which conductivity actually drops with increased concentration over 15 % (see Figure 2). Conductivity graphs, such as Figure 2 and the many others included in Emerson Process Management’s Conductance Data for Commonly Used Chemicals, usually apply to pure mixtures of water and the indicated chemical. Although the conductivity of a mixture is usually close to the sum of the conductivity of its components, the presence of significant amounts of certain substances (iron, copper, and some sugars, for example) can actually lower the measured conductivity. Conductivity data is temperature dependent and is frequently stated at a reference temperature of 25 °C (77 °F). Temperature correction is specific to the application and can be very important when extreme and/or variable temperature is likely. Instrumentation Emerson Process Management’s Liquid Division has a complete line of electrodeless (toroidal) conductivity sensors that are especially suitable for monitoring chemical concentration. The most popular and versatile sensor is the 228 insertion/submersion sensor, which can also be used in a high pressure retraction assembly. Sensors having other installation options include the large bore 226 sensors, sanitary 225, and the flow-through 242. Consult the appropriate Product Data Sheet for complete details. Compatible Toroidal Conductivity analyzers include the 5081-T and 1066 HART and FOUNDATION™ Fieldbus Transmitters, the 1056 Conductivity Analyzer, and the 56 Conductivity Analyzer/Controller. Each of these models has been specifically designed for measuring percent.
Abrir o catálogo na página 1
228 Toroidal Conductivity Sensor Digital Communications: HART® and Profibus® DP communications with full features and functions. High Resolution full-color screen: easily viewed process measurements and on-screen data trend graphs. User help screens: detailed instructions and troubleshooting in multiple languages. Data logger and event logger: download process data and alarm conditions with time and date stamps via USB 2.0 data port. Control - PID and time proportional capabilities. Also includes synchronize interval timers and four special application functions. Figure 1 - Chemical...
Abrir o catálogo na página 2Todos os catálogos e folhetos técnicos Emerson Automation Solutions - ROSEMOUNT
-
VPS 53 Vapor Pressure Sensor
2 Páginas
-
ROSEMOUNT 3051 PRESSURE PRODUCTS
2 Páginas
-
EasyHeat™ XD Cable Kits
2 Páginas
-
FRL Accessories
14 Páginas
-
TankRadar Pro
32 Páginas
-
Rosemount™ 2140 Level Detector
22 Páginas
-
Roxar subsea SenCorr PTPT sensor 10K
2 Páginas
-
Roxar subsea PIG
2 Páginas
-
Roxar subsea SenCorr PTPT sensor 15K
2 Páginas
-
Roxar subsea Sand monitor
2 Páginas
-
Roxar subsea CM10K
2 Páginas
-
Roxar PTPT15K
2 Páginas
-
Rosemount TankRadar OFC
2 Páginas
-
Rosemount™ 2140:SIS Level Detector
22 Páginas
-
Rosemount 5708 Series 3D Solids Scanner
30 Páginas
-
SW-300
4 Páginas
-
DL8000
12 Páginas
-
Rosemount™ 8800D Series Vortex Flowmeter
82 Páginas
-
Rosemount™ 3144P Temperature Transmitter
82 Páginas
-
Rosemount™ 3051 Pressure Transmitter
82 Páginas
-
DeltaV Analyze
8 Páginas
-
Fisher 657 and 667 Diaphragm Actuators
16 Páginas
-
DeltaV SIS with Electronic Marshalling
48 Páginas
-
AMS Machine Works
4 Páginas
-
Emerson Smart Wireless Gateway
4 Páginas
-
DeltaV Executive Portal
7 Páginas
-
Fisher 646 Electro-Pneumatic Transducer
20 Páginas
-
1500XA Gas Chromatograph
8 Páginas
-
Rosemount 3051S Series of Instrumentation
162 Páginas
-
Rosemount 975UR
4 Páginas
-
Rosemount 975HR
4 Páginas
-
Rosemount 975UF
4 Páginas
-
Rosemount 975MR
4 Páginas
-
CT5400 Process Gas Analyzer
4 Páginas
-
CT5200 Industrial Gas Analyzer
4 Páginas
-
CT2211 Leak Detection System
4 Páginas
-
OPM 4001 Opacity/Dust Density Monitor
12 Páginas
-
6888 In Situ Flue Gas Oxygen Transmitter
16 Páginas
-
Combustion Analysis Solutions
6 Páginas
-
X-STREAM X2GK - Compact Gas Analyzer
8 Páginas
-
Process Gas Analysis Solutions
8 Páginas
-
On-line Gas Analysis in Urea Plants
2 Páginas
-
Lye Peeling of Fruits and Vegetables
2 Páginas
-
Leak Detection Using Conductivity
3 Páginas
-
Improve Copper Yield in Flotation
2 Páginas
-
Desalination of Seawater
2 Páginas
-
Conductivity Measurements in Brewing
2 Páginas
-
700XA Process Gas Chromatograph
12 Páginas
-
Fixed Gas Detector Calibration Kits
2 Páginas
-
MT Ultrasonic Portable Mapping Tool
2 Páginas
-
Incus Ultrasonic Gas Leak Detector
6 Páginas
-
01-TT Ultrasonic Portable Test Tool
2 Páginas
-
SafeGuard Alarm Controller
2 Páginas
-
Safety Monitoring
6 Páginas
-
Advanced Power Analytical Solutions
8 Páginas
-
AMS Suite
16 Páginas
-
Drinking Water Sht 2V2
2 Páginas
-
Liquid Analysis for Metal Extraction
12 Páginas
-
Line Card
2 Páginas
-
Installation & Calibration Equipment
48 Páginas
-
Drinking Water Industry
16 Páginas
-
SafeGuard 16 Channel Controller
2 Páginas
-
Explosion Proof Motion Detector
2 Páginas
-
Explosion Proof Video Camera
2 Páginas
-
Phoenix Triple IR Flame Detector
4 Páginas
-
Net Safety UV/IR Flame Detector
4 Páginas
-
Net Safety UV Flame Detector
4 Páginas
-
Millennium II BASIC Gas Detector
4 Páginas
-
Millennium Toxic Gas Detector
2 Páginas
Catálogos arquivados
-
UV/IRS Flame Detector
4 Páginas
-
UVS Flame Detector
4 Páginas
-
UV/IRS-H2 and UVS-H2 Flame Detectors
6 Páginas