Sustainable Innovation, Quality Standardization and Dynamism Ekin Endustriyel, which has entered Turkish heating sector by exporting of plated heat exchangers, is known with customer focused vision and dynamism. Ekin has expanded into new and upcoming investments. One of the main steps was gaining the identity of being a producer. Ekin has started the production of plate heat exchangers with the brand of "MIT". We have grown in the philosophy of quality, through initially adapting to ISO Quality Management. MIT plate heat exchangers have become a solution for engineering problems in the...
Abrir o catálogo na página 3
Brazed Heat Exchanger
Abrir o catálogo na página 5
MIT BRAZED HEAT EXCHANGERS MIT brazed heat exchangers are used in refrigeration units as evaporators, condensers, heating applications and instantaneous heaters and in their specific applications. MIT offers the most suitable solutions with a wide range of heat exchangers produced with high quality components. Capacity and connections for specific applications can be produced as desired. MIT brazed heat exchangers save space thanks to their compact design. CAPACITY CHART PHE Information Cooling Capacity / Heat Capacity (kW) Heat Transfer Area (m ) 2 Standard Design Pressure (bar) Height...
Abrir o catálogo na página 6
MIT brazed plate heat exchangers have been designed for cooling, ventilation and heating processes and have been used safely in these systems for years. Information • Minimum temperature: -196 °C • Maximum temperature: +200 °C • Design pressure: 30-70 bar • Suitable for standard and high pressures • Cooling capacity • Connection type: Threaded, brazed • Copper, nickel and stainless
Abrir o catálogo na página 7
MIT BRAZED HEAT EXCHANGERS Model Horizontal Axis Range (mm) Vertical Axis Range (mm) Horizontal Axis Range (mm) Vertical Axis Range (mm) Standard Connections Optional Connections Max. Threaded Connection Diameter Max. Brazed Connection Diameter Materials Plate Material Connection Material Braze Material Copper (Standard) or Stainless
Abrir o catálogo na página 8
Display of Brazed Heat Exchangers MIT brazed plate heat exchangers can be designed with channel plates with different heat transfer characteristics. H-Type: The plate has wide-angle channels to make the heat transfer to turbulence the fluid's flow characteristic. Plate Type HLM Design Pressure MPa L-Type: Has narrow angles. This reduces the loss of pressure, but the reduction in turbulence reduces heat transfer. Number of Plates Model No Copper Brazing M-Type: A combination of L and H type plates. These plates are particularly preferred when the heat exchange on one side of the plate heat...
Abrir o catálogo na página 9
MIT MB-01 Front and Rear Bodies MIT MB-01 can be copper or nickel brazed heat exchanger. Plate material 316L. Parallel Flow Brazed Plate Heat Exchanger / MIT MB-01 Number of Plates Heat Exchanger Area (m2) Parameters Design Pressure Test Pressure Design Temperature Plate Type Heat Capacity Maximum Number of Plates Brazed Connection Screwed Connection Ekin offers various types of brazed and screwed connections to its customers.
Abrir o catálogo na página 10
MIT MB-02 can be copper or nickel brazed heat exchanger. Plate material 316L. Parallel Flow Brazed Plate Heat Exchanger / MIT MB-02 Number of Plates Heat Exchanger Area (m2) Parameters Design Pressure Test Pressure Design Temperature Plate Type Heat Capacity Maximum Number of Plates Brazed Connection Screwed Connection Ekin offers various types of brazed and screwed connections to its customers.
Abrir o catálogo na página 11
Channels of Front Plate MIT MB-03 can be copper or nickel brazed heat exchanger. Plate material 316L. Cross Flow Brazed Plate Heat Exchanger / MIT MB-03 Number of Plates Heat Exchanger Area (m2) Parameters Design Pressure Test Pressure Design Temperature Plate Type Heat Capacity Maximum Number of Plates Brazed Connection Screwed Connection Ekin offers various types of brazed and screwed connections to its customers.
Abrir o catálogo na página 12
MIT MB-04 can be copper or nickel brazed heat exchanger. Plate material 316L. Parallel Flow Brazed Plate Heat Exchanger / MIT MB-04 Number of Plates Heat Exchanger Area (m2) Parameters Design Pressure Test Pressure Design Temperature Plate Type Heat Capacity Maximum Number of Plates Brazed Connection Screwed Connection Ekin offers various types of brazed and screwed connections to its customers.
Abrir o catálogo na página 13
MIT MB-05 can be copper or nickel brazed heat exchanger. Plate material 316L. Parallel Flow Brazed Plate Heat Exchanger / MIT MB-05 Number of Plates Heat Exchanger Area (m2) Parameters 30 bar (A type) 45 bar (B type) Design Pressure Test Pressure Design Temperature Plate Type Heat Capacity Maximum Number of Plates Brazed Connection Screwed Connection Ekin offers various types of brazed and screwed connections to its customers.
Abrir o catálogo na página 14
MIT MB-06 can be copper or nickel brazed heat exchanger. Plate material 316L. Parallel Flow Brazed Plate Heat Exchanger / MIT MB-06 Number of Plates Heat Exchanger Area (m2) Parameters 30 bar (A type) 45 bar (B type) Design Pressure Test Pressure Design Temperature Plate Type Heat Capacity Maximum Number of Plates Brazed Connection Screwed Connection Ekin offers various types of brazed and screwed connections to its customers.
Abrir o catálogo na página 15
MIT MB-07 can be copper or nickel brazed heat exchanger. Plate material 316L. Parallel Flow Brazed Plate Heat Exchanger MIT MB-07 Number of Plates Heat Exchanger Area (m2) Parameters 30 bar (A type) 45 bar (B type) Design Pressure Test Pressure Design Temperature Plate Type Heat Capacity Maximum Number of Plates Brazed Connection Screwed Connection Ekin offers various types of brazed and screwed connections to its customers.
Abrir o catálogo na página 16
Parallel Flow MIT MB-08 can be copper or nickel brazed heat exchanger. Plate material 316L. Brazed Plate Heat Exchanger MIT MB-08 Number of Plates Heat Exchanger Area (m2) Parameters 30 bar (A type) 45 bar (B type) Design Pressure Test Pressure Design Temperature Plate Type Heat Capacity Maximum Number of Plates Brazed Connection Screwed Connection Ekin offers various types of brazed and screwed connections to its customers.
Abrir o catálogo na página 17Todos os catálogos e folhetos técnicos Ekin Industrial
-
EKİN PRESENTATION 2023
77 Páginas
-
GENERAL PRODUCT CATALOGUE 2023
600 Páginas
-
CERTIFICATES CATALOGUE
82 Páginas
-
SEPARATORS PRODUCT CATALOGUE
22 Páginas
-
HYDRAULIC OIL COOLER PRODUCT CATALOGUE
24 Páginas
-
PRESSURE VESSELS GENERAL CATALOGUE
60 Páginas
-
EXPANSION TANK PRODUCT CATALOGUE
20 Páginas
-
AIR TANK PRODUCT CATALOGUE
16 Páginas
-
FOOD GRADE SYSTEMS GENERAL CATALOGUE
48 Páginas
-
HEAT TRANSFER GENERAL CATALOGUE
108 Páginas
-
TUBE HEAT EXCHANGER PRODUCT CATALOGUE
50 Páginas
-
PLATE HEAT EXCHANGER PRODUCT CATALOGUE
30 Páginas
-
THERMOREGULATOR PRODUCT CATALOGUE
14 Páginas
-
COMPLETE SYSTEM UNITS GENERAL CATALOGUE
40 Páginas
-
SUBSTATIONS PRODUCT CATALOGUE
20 Páginas
-
HEAT STATIONS PRODUCT CATALOGUE
28 Páginas
-
ENERGY SYSTEMS GENERAL CATALOGUE
80 Páginas
-
SOLAR COLLECTORS PRODUCT CATALOGUE
20 Páginas
-
BOILER PRODUCT CATALOGUE
60 Páginas
-
FLUID TRANSFER GENERAL CATALOGUE
78 Páginas
-
AIR DIAPHRAGM PUMP PRODUCT CATALOGUE
20 Páginas
-
DINO DRUM PUMP PRODUCT CATALOGUE
18 Páginas
-
INJECTA DOSING PUMP PRODUCT CATALOGUE
18 Páginas
-
LOBE PUMP PRODUCT CATALOGUE
18 Páginas
-
NOVA ROTORS MONO PUMP PRODUCT CATALOGUE
20 Páginas
-
MIT BLOWER PODUCT CATALOGUE
16 Páginas
-
AIROO ROOTS BLOWER PRODUCT CATALOGUE
20 Páginas
-
VALVE GENERAL CATALOGUE
16 Páginas
Catálogos arquivados
-
MAGNETO ACID PUMP PRODUCT CATALOGUE
34 Páginas
-
GENERAL PRODUCT CATALOGUE 2021
262 Páginas