Excertos do catálogo

Edwards TIC product range is a series of vacuum instrument controllers providing compact control with a large, clear graphical display, an intuitive user interface and serial communications. program provides full remote setup, control and data logging functions via The range includes three-head, six-head, and six-head capacitance manometer compatible versions, which support and automatically recognize up to six Edwards Active vacuum gauges, including the Active Ion Gauge Controller (EB version) and Barocel™ capacitance manometers, to provide coverage from 2000 to Capacitance Manometer Protection Six User Configurable Relay Set-points Display of Relay Status One 0-10 V Buffered Analog Output for each gauge channel Web-based Product Support page Direct Pressure Readout of common conversion factors User-Configurable Display Options include: - Option to display one, three, or six channels - Ability to select gauge order when cycling - The display Assign a four character alpha- numeric name for each gauge (e.g RV1, LL2,
Abrir o catálogo na página 1
Technical Data ELECTRICAL DATA Connector type Electrical supply Power consumption Earth stud OPERATING AND STORAGE DATA Ambient operating temperature range Ambient storage temperature range Maximum ambient operating humidity Maximum operating altitude I EC rated pollution degree MECHANICAL DATA The unit is self-protecting and has no user replaceable fuse. The unit will recover once any overload is removed. The figure illustrates the use of Active Pirani Gauge (APG100) and Active Inverted Magnetron Gauges (AIM), which may be replaced by asingleWide Range Gauge (WRG). The logic interface (M)...
Abrir o catálogo na página 2
External Interfaces And Configuration Options Logic interface Control inputs Status outputs Serial interface The logic interface connector may be used either to link to system relays, a higher-level control system, or an optional relay box. By utilizing the relay box pass-through connector, a combination of a higher-level control system and relay box may be used. Gauge enable: System interlock: Analog output: Open when high: 4 to 24 V DC SYSI closed when low: < 0.5 V DC Open when high: 4 to 24 V DC 1 for each gauge channel 0-10 V DC The TIC has two built-in communications protocols, RS232...
Abrir o catálogo na página 3
Access the Configuration Manager in order to: • Link gauge channels for pressure control of high vacuum gauges • Create, save, and load custom configurations • Lock the TIC software configuration or front panel Each TIC is supplied with a fully functional Windows™ based PC software interface, which replicates and adds to the TIC embedded control menus. The PC Monitor software enables TIC systems to be configured, controlled and monitored from a single PC: • Control gauge functions such as degas and calibrate • Energize or de-energize gauges • Access other PC Monitor control functions A...
Abrir o catálogo na página 4
Compatible Gauges * The AIGX draws 8W in normal operation, 15W in degas mode. The total power available to drive the gauges is limited to 38 W. Additionally, for capacitance manometers, power Two relay boxes are available to allow the TIC set point outputs to operate either three 250V AC, 3A or six 250V AC, 5A (non-inductive) changeover relays. The relay box is equipped with a logic connector to allow interfacing with the TIC, and with a separate bypass connector for interfacing with other external control equipment. 1 250V ac 3A changeover relays (3 channel) 2 Logic interface (from TIC)
Abrir o catálogo na página 5
Ordering Information TIC Instrument Controller 3 head RS232/RS485 TIC Instrument Controller 6 head RS232/RS485 TIC Instrument Controller 6 head RS232/RS485 Capman Calibrated Instrument Controllers Controllers are supplied with a certificate of calibration traceable to national standards. TIC Instrument Controller 3 head RS232/RJ485 + calibration certificate TIC Instrument Controller 6 head RS232/RJ485 +calibration certificate TIC Instrument Controller 6 head Capman + calibration certificate The above controllers are calibrated on their own without gauges. Contact Edwards for controllers...
Abrir o catálogo na página 6Todos os catálogos e folhetos técnicos EDWARDS
-
VS16K & IS16K VACUUM SWITCHES
2 Páginas
-
SPEEDIVALVE
2 Páginas
-
GASCHECK G4 GAS LEAK DETECTOR
4 Páginas
-
GV
12 Páginas
-
XDD1
2 Páginas
-
PGC
2 Páginas
-
8200
2 Páginas
-
IS 320FX
2 Páginas
-
RGA
8 Páginas
-
Vacuum Measurement and Control Brochure
32 Páginas
-
EH
2 Páginas
-
RV
8 Páginas
-
nXDS
12 Páginas
-
XDS series
4 Páginas
-
EOSi ROTARY SCREW VACUUM PUMPS
12 Páginas
-
ACTIVE DIGITAL CONTROLLER (ADC)
4 Páginas
-
ACTIVE WIDE RANGE GAUGE (WRG)
2 Páginas
-
nEXT TURBOMOLECULAR PUMPING STATION
2 Páginas
-
EDP CHEMICAL DRY VACUUM PUMP
4 Páginas
-
CXS CHEMICAL DRY VACUUM PUMPS
12 Páginas
-
CXS chemical dry vacuum pump
4 Páginas
-
EDC DRY CLAW VACUUM PUMPS
8 Páginas
-
gxs dry screw vacuum pumps
20 Páginas
-
nXLi DRY PUMPS
2 Páginas
-
XDD1 DIAPHRAGM VACUUM PUMP
2 Páginas
-
XDS35i DRY SCROLL PUMPS
4 Páginas
-
XDS DRY SCROLL PUMPS
4 Páginas
-
nXDS DRY SCROLL PUMPS
12 Páginas
-
Chemical Process Industries Brochure
12 Páginas
-
GV400 + EH2600-EH4200 datasheet
4 Páginas
-
T-STATION 85
2 Páginas
-
AIM
2 Páginas
-
WRG
2 Páginas
-
Active ion gauge (AIGX)
2 Páginas
-
ASG2
2 Páginas
-
ELD500
8 Páginas
-
nEXT Turbo Pumps
12 Páginas
-
EXT Turbo Pumps
4 Páginas
-
IPUP2 Dry Pump
2 Páginas
-
iXL1000 Dry Pump
2 Páginas
-
iXH Dry Pumps HF
2 Páginas
-
iXH Dry Pumps
2 Páginas
-
iH Dry Pumps Product
12 Páginas
-
RV Acoustic Enclosures
2 Páginas
-
RV Pumps
8 Páginas
-
ES Rotary Vane Pumps
16 Páginas
-
Small EM Pumps
12 Páginas
-
MAXX Dry Systems
16 Páginas
-
BGV Gate Valve Manual/Pneumatic
4 Páginas
-
BGV Gate Valve w/LOTO
4 Páginas
-
GXS Dry Pumps
20 Páginas
-
nXDS Acoustic Enclosures
2 Páginas
-
nXDS Accessories
32 Páginas
-
TiTan Ion Pumps
4 Páginas
-
EDP Pumps
4 Páginas
-
CXS Dry Pumps
12 Páginas
-
Edwards_Product_Catalogue
604 Páginas
-
ADC Datasheet
4 Páginas
-
Active Thermocouple Gauges Datasheet
2 Páginas
-
Acoustic enclosures
2 Páginas
-
nEXT Brochure
12 Páginas
-
nXDS Scroll Pumps
12 Páginas
-
PRODUCT CATALOGUE 2012
470 Páginas
-
CXS Dry Pump
9 Páginas
-
EV Brochure
6 Páginas
-
GXS Dry Screw Pumps & Combinations
12 Páginas
-
Spectra G
4 Páginas
-
Atlas? Gas Abatement Systems
2 Páginas
-
GX Next Generation Dry Pumps
4 Páginas
-
iGX Dry Pumps
4 Páginas
-
iXL120 Dry Pump
2 Páginas
-
VS16K & IS16K Vacuum Switches
2 Páginas
-
CG16K Capsule Dial Gauges
2 Páginas
-
T-Station 75
2 Páginas
-
Turbo & Active Gauge Controller
2 Páginas
-
EXT75-255DX
6 Páginas
-
XDS Dry Scroll Pump
6 Páginas
-
Barocel® 600 Datasheet
2 Páginas
-
Active Ion Gauge Datasheet
4 Páginas
-
Wide Range Gauge Datasheet
2 Páginas
-
Active Strain Gauge Datasheet
2 Páginas
-
APGX-H Datasheet
4 Páginas
-
APG100 Datasheet
2 Páginas
-
Vapour Booster Pumps
60 Páginas
-
HT16B Diffusion Pump Datasheet
2 Páginas
-
STP Pump with Integrated Controller
8 Páginas
-
RV ATEX Rotary Vane Pumps
34 Páginas
-
EM18 Vacuum Pumps Datasheet
2 Páginas
-
RV Rotary Vane Pumps
6 Páginas
-
XDS Scroll Pumps
2 Páginas
Catálogos arquivados
-
Alpha 14+ Liquid Ring Pump Datasheet
2 Páginas
-
LR1A23000 Liquid Ring Pump datasheet
2 Páginas
-
LR1A5000 Liquid Ring Pump datasheet
2 Páginas
-
LR1A4000 Liquid Ring Pump datasheet
2 Páginas
-
LR1A400 Liquid Ring Pump datasheet
2 Páginas
-
LR1A300 Liquid Ring Pump datasheet
2 Páginas
-
LR1A200 Liquid Ring Pump datasheet
2 Páginas
-
RV Brochure
6 Páginas
-
RV Rotary vane pump manual
58 Páginas
-
Temperature Control Unit Datasheet
4 Páginas
-
Vacuum Solutions for Process Industries
12 Páginas
-
D-Lab Diaphragm vacuum pump
4 Páginas
-
Dry pump brochure
12 Páginas
-
Rotary vane datasheet
2 Páginas
-
Liquid Ring Pumps
2 Páginas
-
Mechanical Booster
12 Páginas