TIC Instrument controller Datasheet
1 / 6Páginas

{{requestButtons}}

Excertos do catálogo

TIC Instrument controller Datasheet - 1

Edwards TIC product range is a series of vacuum instrument controllers providing compact control with a large, clear graphical display, an intuitive user interface and serial communications. program provides full remote setup, control and data logging functions via The range includes three-head, six-head, and six-head capacitance manometer compatible versions, which support and automatically recognize up to six Edwards Active vacuum gauges, including the Active Ion Gauge Controller (EB version) and Barocel™ capacitance manometers, to provide coverage from 2000 to Capacitance Manometer Protection Six User Configurable Relay Set-points Display of Relay Status One 0-10 V Buffered Analog Output for each gauge channel Web-based Product Support page Direct Pressure Readout of common conversion factors User-Configurable Display Options include: - Option to display one, three, or six channels - Ability to select gauge order when cycling - The display Assign a four character alpha- numeric name for each gauge (e.g RV1, LL2,

Abrir o catálogo na página 1
TIC Instrument controller Datasheet - 2

Technical Data ELECTRICAL DATA Connector type Electrical supply Power consumption Earth stud OPERATING AND STORAGE DATA Ambient operating temperature range Ambient storage temperature range Maximum ambient operating humidity Maximum operating altitude I EC rated pollution degree MECHANICAL DATA The unit is self-protecting and has no user replaceable fuse. The unit will recover once any overload is removed. The figure illustrates the use of Active Pirani Gauge (APG100) and Active Inverted Magnetron Gauges (AIM), which may be replaced by asingleWide Range Gauge (WRG). The logic interface (M)...

Abrir o catálogo na página 2
TIC Instrument controller Datasheet - 3

External Interfaces And Configuration Options Logic interface Control inputs Status outputs Serial interface The logic interface connector may be used either to link to system relays, a higher-level control system, or an optional relay box. By utilizing the relay box pass-through connector, a combination of a higher-level control system and relay box may be used. Gauge enable: System interlock: Analog output: Open when high: 4 to 24 V DC SYSI closed when low: < 0.5 V DC Open when high: 4 to 24 V DC 1 for each gauge channel 0-10 V DC The TIC has two built-in communications protocols, RS232...

Abrir o catálogo na página 3
TIC Instrument controller Datasheet - 4

Access the Configuration Manager in order to: • Link gauge channels for pressure control of high vacuum gauges • Create, save, and load custom configurations • Lock the TIC software configuration or front panel Each TIC is supplied with a fully functional Windows™ based PC software interface, which replicates and adds to the TIC embedded control menus. The PC Monitor software enables TIC systems to be configured, controlled and monitored from a single PC: • Control gauge functions such as degas and calibrate • Energize or de-energize gauges • Access other PC Monitor control functions A...

Abrir o catálogo na página 4
TIC Instrument controller Datasheet - 5

Compatible Gauges * The AIGX draws 8W in normal operation, 15W in degas mode. The total power available to drive the gauges is limited to 38 W. Additionally, for capacitance manometers, power Two relay boxes are available to allow the TIC set point outputs to operate either three 250V AC, 3A or six 250V AC, 5A (non-inductive) changeover relays. The relay box is equipped with a logic connector to allow interfacing with the TIC, and with a separate bypass connector for interfacing with other external control equipment. 1 250V ac 3A changeover relays (3 channel) 2 Logic interface (from TIC)

Abrir o catálogo na página 5
TIC Instrument controller Datasheet - 6

Ordering Information TIC Instrument Controller 3 head RS232/RS485 TIC Instrument Controller 6 head RS232/RS485 TIC Instrument Controller 6 head RS232/RS485 Capman Calibrated Instrument Controllers Controllers are supplied with a certificate of calibration traceable to national standards. TIC Instrument Controller 3 head RS232/RJ485 + calibration certificate TIC Instrument Controller 6 head RS232/RJ485 +calibration certificate TIC Instrument Controller 6 head Capman + calibration certificate The above controllers are calibrated on their own without gauges. Contact Edwards for controllers...

Abrir o catálogo na página 6

Todos os catálogos e folhetos técnicos EDWARDS

  1. SPEEDIVALVE

    2 Páginas

  2. GV

    12 Páginas

  3. XDD1

    2 Páginas

  4. PGC

    2 Páginas

  5. 8200

    2 Páginas

  6. IS 320FX

    2 Páginas

  7. RGA

    8 Páginas

  8. EH

    2 Páginas

  9. RV

    8 Páginas

  10. nXDS

    12 Páginas

  11. XDS series

    4 Páginas

  12. nXLi DRY PUMPS

    2 Páginas

  13. T-STATION 85

    2 Páginas

  14. AIM

    2 Páginas

  15. WRG

    2 Páginas

  16. ASG2

    2 Páginas

  17. ELD500

    8 Páginas

  18. nEXT Turbo Pumps

    12 Páginas

  19. EXT Turbo Pumps

    4 Páginas

  20. IPUP2 Dry Pump

    2 Páginas

  21. iXL1000 Dry Pump

    2 Páginas

  22. iXH Dry Pumps HF

    2 Páginas

  23. iXH Dry Pumps

    2 Páginas

  24. RV Pumps

    8 Páginas

  25. Small EM Pumps

    12 Páginas

  26. MAXX Dry Systems

    16 Páginas

  27. GXS Dry Pumps

    20 Páginas

  28. nXDS Accessories

    32 Páginas

  29. TiTan Ion Pumps

    4 Páginas

  30. EDP Pumps

    4 Páginas

  31. CXS Dry Pumps

    12 Páginas

  32. ADC Datasheet

    4 Páginas

  33. nEXT Brochure

    12 Páginas

  34. nXDS Scroll Pumps

    12 Páginas

  35. CXS Dry Pump

    9 Páginas

  36. EV Brochure

    6 Páginas

  37. Spectra G

    4 Páginas

  38. iGX Dry Pumps

    4 Páginas

  39. iXL120 Dry Pump

    2 Páginas

  40. T-Station 75

    2 Páginas

  41. EXT75-255DX

    6 Páginas

  42. APGX-H Datasheet

    4 Páginas

  43. APG100 Datasheet

    2 Páginas

  44. XDS Scroll Pumps

    2 Páginas

Catálogos arquivados

  1. RV Brochure

    6 Páginas

  2. Dry pump brochure

    12 Páginas

  3. Liquid Ring Pumps

    2 Páginas

  4. Mechanical Booster

    12 Páginas