Active Ion Gauge Controller Datasheet
1 / 2Páginas

{{requestButtons}}

Excertos do catálogo

Active Ion Gauge Controller Datasheet - 1

ACTIVE ION GAUGE CONTROLLER RANGE 5 X 103 TO 2 X 10 11 mbar The Edwards Active Ion Gauge Controller (IGC) provides all the power, control and signal conditioning required to run one or When connected to a Edwards TIC Instrument Controller the user has full control of the ion gauge functions from the TIC front panel. This includes features such as automatic emission current selection and interlock with other gauge types. Alternatively, the IGC can be linked directly to a control system such as a PLC to give the OEM or system builder direct access to control inputs and signal outputs. • Wide measurement range - Electron beam degas versions: • Selection of head available - Choice of electron beam degas, nude or glass encapsulated, tungsten or thoriated iridium • Flexible cabling system - Ion gauge cables are available in 2 and 3m lengths including bakeable versions. Active gauge cables to link IGC and AGC are available • Vacuum interlock through an auxiliary low vacuum Active gauge - To protect the ion gauge from accidental operation at high pressure it can be interlocked through an Active Pirani or thermocouple gauge connected to the IGC or • Ratiomatic measurement system - Improved measurement accuracy - Allows soft start on filament power-up giving an added degree of filament protection • Choice of Edwards interface (EHVI) or parallel command and status port (PCSP) - EHVI: allows connection to Edwards TIC Instrument Controller - PCSP: 15 way D-type connector giving access to all control input and signal outputs

Abrir o catálogo na página 1
Active Ion Gauge Controller Datasheet - 2

ACTIVE ION GAUGE CONTROLLER RANGE 5 X 103 TO 2 X 10 11 mbar Technical Data Power supply Input voltage range Input frequency range Main supply socket Temperature range Relative humidity (non condensing) Enclosure rating Pressure range Electron beam degas (EBEAM) Emission current Filament power supply Note: 2 head versions of the IGC will only drive one head at a time Degas power Electron beam (EBEAM) PCSP interface PCSP interface socket or EHVI (AGC) interface socket plus Auxilliary gauge socket Without rack mounting kit With rack mounting kit Electronic design Electromagnetic compatibility...

Abrir o catálogo na página 2

Todos os catálogos e folhetos técnicos EDWARDS

  1. SPEEDIVALVE

    2 Páginas

  2. GV

    12 Páginas

  3. XDD1

    2 Páginas

  4. PGC

    2 Páginas

  5. 8200

    2 Páginas

  6. IS 320FX

    2 Páginas

  7. RGA

    8 Páginas

  8. EH

    2 Páginas

  9. RV

    8 Páginas

  10. nXDS

    12 Páginas

  11. XDS series

    4 Páginas

  12. nXLi DRY PUMPS

    2 Páginas

  13. T-STATION 85

    2 Páginas

  14. AIM

    2 Páginas

  15. WRG

    2 Páginas

  16. ASG2

    2 Páginas

  17. ELD500

    8 Páginas

  18. nEXT Turbo Pumps

    12 Páginas

  19. EXT Turbo Pumps

    4 Páginas

  20. IPUP2 Dry Pump

    2 Páginas

  21. iXL1000 Dry Pump

    2 Páginas

  22. iXH Dry Pumps HF

    2 Páginas

  23. iXH Dry Pumps

    2 Páginas

  24. RV Pumps

    8 Páginas

  25. Small EM Pumps

    12 Páginas

  26. MAXX Dry Systems

    16 Páginas

  27. GXS Dry Pumps

    20 Páginas

  28. nXDS Accessories

    32 Páginas

  29. TiTan Ion Pumps

    4 Páginas

  30. EDP Pumps

    4 Páginas

  31. CXS Dry Pumps

    12 Páginas

  32. ADC Datasheet

    4 Páginas

  33. nEXT Brochure

    12 Páginas

  34. nXDS Scroll Pumps

    12 Páginas

  35. CXS Dry Pump

    9 Páginas

  36. EV Brochure

    6 Páginas

  37. Spectra G

    4 Páginas

  38. iGX Dry Pumps

    4 Páginas

  39. iXL120 Dry Pump

    2 Páginas

  40. T-Station 75

    2 Páginas

  41. EXT75-255DX

    6 Páginas

  42. APGX-H Datasheet

    4 Páginas

  43. APG100 Datasheet

    2 Páginas

  44. XDS Scroll Pumps

    2 Páginas

Catálogos arquivados

  1. RV Brochure

    6 Páginas

  2. Dry pump brochure

    12 Páginas

  3. Liquid Ring Pumps

    2 Páginas

  4. Mechanical Booster

    12 Páginas