Excertos do catálogo

Electrical Sector Solutions Motor Control and Protection
Abrir o catálogo na página 1
Volume 1—Residential and Light Commercial Volume 2—Commercial Distribution Volume 3—Power Distribution and Control Assemblies Volume 4—Circuit Protection Volume 5—Motor Control and Protection Tab 1—IEC Contactors and Starters . . . . . . . . . . . . . . . . . . . Tab 4—Definite Purpose Contactors and Starters . . . . . . . . Appendix 1—Eaton Terms & Conditions . . . . . . . . . . . . . . . Appendix 2—Catalog Parent Number Index . . . . . . . . . . . . Appendix 3—Alphabetical Product Index . . . . . . . . . . . . . . Volume 6—Solid-State Motor Control Volume 7—Logic Control, Operator...
Abrir o catálogo na página 2
Copyright Dimensions, Weights and Ratings Dimensions, weights and ratings given in this catalog are approximate and should not be used for construction purposes. Drawings containing exact dimensions are available upon request. All listed product specifications and ratings are subject to change without notice. Photographs are representative of production units. Terms and Conditions All prices and discounts are subject to change without notice. When price changes occur, they are published in Eaton’s Price and Availability Digest (PAD). All orders accepted by Eaton’s Electrical Sector are...
Abrir o catálogo na página 3
Eaton is a global leader in power distribution, power quality, control and automation, and monitoring products. At Eaton, we believe a reliable, efficient and safe power system is the foundation of every successful enterprise. Through innovative technologies, cutting-edge products and our highly skilled services team, we empower businesses around the world to achieve a powerful advantage. In addition, Eaton is committed to creating and maintaining powerful customer relationships built on a foundation of excellence. From the products we manufacture to our dedicated customer service and...
Abrir o catálogo na página 4
Icons Green Leaf Eaton Green Solutions are products, systems or solutions that represent Eaton benchmarks for environmental performance. The green leaf symbol is our promise that the solution has been reviewed and documented as offering exceptional, industry-leading environmental benefits to customers, consumers and our communities. Though all of Eaton's products and solutions are designed to meet or exceed applicable government standards related to protecting the environment, our products with the Green Leaf designation further provide “exceptional environmental benefit”. Learn Online When...
Abrir o catálogo na página 5
IEC Contactors and Starters IEC Contactors and Starters XT IEC Power Control Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Contactors and Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Thermal Overload Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C440/XT Electronic Overload Relay ....
Abrir o catálogo na página 6
IEC Contactors and Starters XT IEC Power Control Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . . Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . . Contactors and Starters . . . . . . . . . . . . . . . . . . . . Thermal Overload Relays . . . . . . . . . . . . . . . . . . . C440/XT Electronic Overload Relay . . . . . . . . . . . Manual Motor Protectors . . . . . . . . . . . . . . . . . . . Combination Motor Controllers . . . . . . . . . . . . . . . XT Electronic Manual Motor Protector . . . . . . . . . Reference Data . . . . . . . . . . . . . . . . . . ....
Abrir o catálogo na página 7
IEC Contactors and Starters XT IEC Power Control Relays and Timers Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . An Eaton Green Solution Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . . Contactors and Starters . . . . . . . . . . . . . . . . . . . . Thermal Overload Relays . . . . . . . . . . . . . . . . . . . ....
Abrir o catálogo na página 8
IEC Contactors and Starters XT IEC Power Control Catalog Number Selection XT—Relays Product Line Prefix XT = XT IEC power control Product Family Code RM = Mini IEC control relay RE = IEC control relay Terminations Blank = Screw terminals C = Spring cage terminals Frame XTRM A = 45 mm—mini XTRE B = 45 mm—standard Coil Code See table on Page V5-T1-5. Conventional Thermal Current Rating 10 = 10A XT MT 6 B 30S 11 B Product Line Prefix XT = XT IEC power control Product Family Code MT = Mini IEC timing relay TR = Electronic timing relay star-delta (wye-delta) Conventional Thermal Current Rating 6...
Abrir o catálogo na página 9
IEC Contactors and Starters XT IEC Power Control Product Selection When Ordering ● Orders must be placed in multiples of the package quantity listed ● DC operated control relays have a built-in suppressor circuit ● Contact terminal numbers to EN50011 ● Coil terminal numbers to EN50005 Mini Control Relays Rated Operational Current AC-15 Ie (A) Conventional Thermal Current Ith (A) Contact Configuration Circuit Symbol Screw Terminal Catalog Number 1 Contact Configuration Rated Operational Current AC-15 Ie (A) Screw Terminal Catalog Number 1 Circuit Symbol Spring Cage Terminal Catalog Number 1...
Abrir o catálogo na página 10
Auxiliary Contacts Front-Mount Auxiliary Contacts for Use with XTRM Mini Control Relays ilf^T'N JJ ™ Thermal Current, Rated Operational Current Contact Sequence © Orders must be placed in multiples of package quantity listed. © One early-make contact (N0E), one late-break contact (NCL). Qty.® Catalog Number Volume 5 —Motor Control and Protection CA08100006E—February 2014 www.eaton.com
Abrir o catálogo na página 11
IEC Contactors and Starters XT IEC Power Control Front-Mount Auxiliary Contacts for Use with XTRE Control Relays 1 Rated Operational Current AC-15 Ie (A) Conventional Thermal Current, Ith (A), Open at 60°C Two-Pole Contact Configuration Screw Terminal Catalog Number Circuit Symbol 58 66 72 84 Notes 1 Interlocked opposing contacts, to IEC/EN 60947-5-1 Annex L (positively driven), within the auxiliary contact modules (not NO and NC contacts) and between the E L auxiliary contacts and built-in contacts of the XTRE control relays. 2 Orders must be placed in multiples of package quantity listed....
Abrir o catálogo na página 12Todos os catálogos e folhetos técnicos Eaton Count Control Products
-
IEC Contactors and Starters_2021
256 Páginas
-
COOPER POWER SERIES
20 Páginas
-
Electrical enclosures
544 Páginas
-
Climate Control Products
34 Páginas
-
Eaton pilot devices
2 Páginas
-
C22 Pilot Devices
4 Páginas
-
Diesel Engine Fire Pump Controllers
2 Páginas
-
VCP-WXC Vacuum circuit breakers
2 Páginas
-
Marina Power & RV Park Equipment
48 Páginas
-
NEMA Contactors and Starters
154 Páginas
-
Terminal Blocks, Fuse Blocks and Fuse Holder
133 Páginas
-
Control Relays and Timers
204 Páginas
-
Motor Protection and Monitoring
144 Páginas
-
PowerXL DE1 Catalog
6 Páginas
-
Expulsion Fuses
72 Páginas
-
Pushbuttons and Indicating Lights
361 Páginas
-
Power Pedestals
90 Páginas
-
Loadcenters and Circuit Breakers
100 Páginas
-
Series GJ
8 Páginas
-
Series CD-CE-CF
10 Páginas
-
Series GH
8 Páginas
-
Low Voltage Assembly Solutions
8 Páginas
-
Improved uptime, reduced cost
2 Páginas
-
Eaton?s solution to arc flash
2 Páginas
-
SAF Drives
1 Páginas
-
Eaton Automated Machine Control
2 Páginas
-
SmartWire-DT
2 Páginas
-
Medium voltage circuit breakers
2 Páginas
-
Cutler-Hammer
12 Páginas
-
BladeUPS (12-60 kW)
12 Páginas
-
9PX (5-11 kVA)
4 Páginas
-
5S (500-1500 VA)
2 Páginas
-
5P Tower (750-3000 VA)
2 Páginas
-
5P Rackmount (500-3000 VA)
2 Páginas
-
3S (350-750 VA)
2 Páginas
-
Alternate Enclosures
4 Páginas
-
Type 7/9 Hazardous Location Starters
19 Páginas
-
Manual Motor Control
10 Páginas
-
Multi-Pak Group Control
13 Páginas
-
HVAC Control
10 Páginas
-
Pump Panels
29 Páginas
-
Reduced Voltage Starters
83 Páginas
-
Lighting Contactors
16 Páginas
-
NEMA Contactors and Starters
80 Páginas
-
Volume 13?Counters, Timers and Tachometers
145 Páginas
-
Volume 11 - Vehicle and Commercial Controls
199 Páginas
-
Volume 06 - Solid-State Motor Control
386 Páginas
-
Volume 04 - Circuit Protection
684 Páginas
-
Molded Case Circuit Breakers
432 Páginas
-
Metering Products
151 Páginas
-
Specific Control & Display Overview
8 Páginas
-
Solutions Energy Savings
8 Páginas
-
Counters, Timers and Tachometers
145 Páginas
Catálogos arquivados
-
IEC Contactors and Starters_2013
251 Páginas
-
Eaton Power Supplies Catalog Supplement
19 Páginas
-
Specific Control & Display Products
92 Páginas