Excertos do catálogo

To Order Call Toll Free: HGD-3000 Hydrogen Gas / Smoke Detector with Intrusion AlarmModel # HGD-3000 Gas Detection GD~SERIES 29 Hydrogen Gas Detection The HGD-3000 Hydrogen Gas and Smoke Detector with optional Silent Intrusion Alarm is designed for unattended battery installations or remote shelters containing gassing lead acid batteries and charging systems. The HGD-3000 will turn on an exhaust fan when hydrogen gas levels reach 1% and will alarm at 2%. This alarm consists of a local 80db horn, a flashing red LED, and a dry contact switch closure for remote alarming. Smoke Detection The photoelectric smoke sensor detects minute combustion products from smoldering wire insulation, battery cases, and other material. When smoke is detected, a distinctive alarm is emitted from the 80db horn and a separate dry contact switch is activated. At this time, the exhaust fan is inhibited in order to deny the fire increased oxygen from outside air. Temperature, Loss of Power, & Intrusion During normal operation and in the absence of an alarm condition, an internal thermostat will turn on the exhaust fan at a preset temperature to reduce heat buildup in the room. Loss of power to the unit will also generate a dry contact alarm. Additionally, an optional infrared intrusion alarm will trigger a silent dry contact switch. Features • Automatic Operation and Continuous 24/7 Monitoring • Highly sensitive and stable solid state hydrogen sensor • Sensitive photoelectric smoke detector module • Internal thermostat for automatic exhaust fan control at 40°C (104°F) with ±5° adjustable range • Save insurance costs - reduce insurance premiums when placed in battery charging rooms Technical Specifications Detection: Alarms: Relay Connections Mounting: Operating Environment: Power Requirements: Compliance: Dimensions: Hydrogen Gas, Smoke, Temperature, Intrusion 10A Relay for Exhaust Fan, 1A Relay for Loss of Power, 1A Relay for Smoke Alarm, 1A Relay for Intrusion, 1A Relay for 2% H2 Concentration RJ45, Punch-Down Block (4) 4.5 mm (3/16 in) screws Temperature: -10 - 40 °C (14 - 104 °F) Standard: 85 - 265 VAC, 50/60 Hz Optional: 17 - 60 VDC IEEE Standard 450; National Protection Agency (NFPA) Article 64; NFPA 2: Hydrogen Technologies Code; Uniform Building Code (UBC) Section 6400; National Electric Code (NEC) Section 480.9 (A); NEC 501.125 (B); NEC 501.105 (1)-3 - use in Class 1 Division 2 Group B. 178 x 120 x 55 mm (7 x 4.75 x 2.5 in) Applications • Utilities and Power Plants • UPS Power Systems • Fuel Cell Test Stations • Nuclear Waste Reforming • Hydrogen Refueling Stations • Fire Department • Battery Suppliers • Battery Charging Rooms • Motive Power • Golf Cart • User Manual • Optional: Silent-Alarm Add-on • Optional: Breakout box for easy-access control • Optional: Junction Box Ordering Information
Abrir o catálogo na página 1Todos os catálogos e folhetos técnicos Eagle Eye Power Solutions
-
NERC PRC-005-02
2 Páginas
-
DLV-Max Battery Testing Kit
1 Páginas
-
DCPS-Shelf-6KW
2 Páginas
-
DCPS-Shelf-9KW
1 Páginas
-
SC-1000
2 Páginas
-
SC-1500
2 Páginas
-
SC-2000
2 Páginas
-
RM-48-2K
2 Páginas
-
RM-48-3K
2 Páginas
-
RM-48-KA
1 Páginas
-
MIS-1000
3 Páginas
-
MIS-2000-series
3 Páginas
-
MIS-3000-series
3 Páginas
-
MIS-4000-series
3 Páginas
-
MIS-5000-series
3 Páginas
-
SIS-1000-series
2 Páginas
-
ENC-1000 Enclosure
1 Páginas
-
ENC-2000
1 Páginas
-
SG-500 Portable Digital Hydromete
1 Páginas
-
BMS-Series Catalog
19 Páginas
-
LB-AC-Digital
1 Páginas
-
LB-60-30 AC Load Bank
1 Páginas
-
BTM-Series
1 Páginas
-
VM-100 Voltage Monitor
1 Páginas
-
VGM-100 Voltage Monitor
1 Páginas
-
ELM-Series Electrolyte Level Monitor
2 Páginas
-
BMS-icom Battery Monitoring System
1 Páginas
-
BDS-Pro Battery Monitoring System
2 Páginas
-
IPQMS Battery Monitoring System
2 Páginas
-
BQMS Battery Monitoring System
2 Páginas
-
BR-500 Battery Regenerator & Charger
1 Páginas
-
HGD-2000 Hydrogen Gas Detector
1 Páginas
-
VS-12 Hydrogen Gas Exhaust Fan
1 Páginas
-
Eagle Eye 2017 Product Catalog
51 Páginas
-
Eagle Eye Motive Power Catalog
12 Páginas
-
TIC-1000 Thermal Imaging Camera
1 Páginas
-
SLB-Series DC Load Banks
3 Páginas
-
LB-Series AC Load Banks
1 Páginas
-
LB-60-100 AC Load Bank
1 Páginas
-
IBEX-Series Portable Battery Testers
2 Páginas
-
GFM-100 Battery Ground Fault Monitor
1 Páginas
-
GFL-1000 Ground Fault Locator
1 Páginas
-
DM-Series Inline Density Meters
1 Páginas
-
DLV-Pro Data Logging Voltmeter
1 Páginas
-
BQMS
2 Páginas
Catálogos arquivados
-
BDL-Series Battery Data Loggers 1.2
1 Páginas
-
VM-100 Battery Voltage Monitor
1 Páginas
-
BDL-Series Battery Data Loggers 1.0
1 Páginas
-
HGD-3000
1 Páginas
-
DC Load Bank
3 Páginas
-
LB-1000
1 Páginas
-
SCR-SCRF
1 Páginas
-
AT10.1 - AT30
1 Páginas
-
SG-100M
1 Páginas
-
SG-1000
1 Páginas
-
SG-Ultra Max
1 Páginas
-
Hydrogen Gas Detector: HGD-2000
1 Páginas
-
Battery Voltmeter: DLV-Pro
1 Páginas
-
Battery Monitoring System: iPQMS
2 Páginas
-
Combustible Gas Detector: GD-3000
1 Páginas
-
DC SLB-Series
3 Páginas
-
AC Load Bank 2013 Catalog
1 Páginas
-
IBEX-Procedures for Testing
3 Páginas
-
SG-5000BT Product Brochure
6 Páginas
-
Eagle Eye SG-5000BT
2 Páginas