48V Battery Monitoring System: BDS-Pro
1 / 2Páginas

Excertos do catálogo

48V Battery Monitoring System: BDS-Pro - 1

To Order Call Toll Free: BDS-Pro Battery Monitoring System Product Description Battery Monitoring Systems The BDS-Pro Battery Monitoring System is designed to measure the aging status of up to 24 jars (or 24 cells) by measuring and recording: string voltage, DC current, jar/cell voltage, internal resistance (I.R.), connection resistance, and temperature. The BDS-Pro is designed for use on vented lead acid, valve regulated lead acid, and nickel-cadmium battery systems. The included Centroid 2 Battery Management Software records measured data for comprehensive trending analysis. The BDS-Pro Battery Monitoring Solution is the most accurate, user-friendly and economic solution for monitoring 24 jars (or 24 cells) systems using 1-16V batteries. Main Processing Unit (MPU) Reduce maintenance costs, improve up-time and manage your battery assets effectively by using the BDS-Pro battery monitoring solution for your system. Protect yourself from battery failure - one of the leading causes of facility downtime with battery monitoring. Product Advantages • • • • • • • 24/7/365 Battery Monitoring Installation and maintenance can be done while battery systems are online Meets IEEE and NERC standard recommendations for battery monitoring Utilizes a patented ripple-removing algorithm Injects minimal current for measurement Simple to install with custom, pre-assembled installation materials Daisy chain up to 20 BDS-Pro units to monitor a total of 480 cells BDS-Pro Installation Battery Management Software • • • • • • Centroid Snet Battery Management Software Displays and records string voltage, string DC current, cell voltage, cell I.R., & cell temperature for all battery systems Trending analysis of measured parameters on a string or jar/ cell level Report generation & ability to export measured data to Excel Send commands to BMS systems Detailed log of alarm outbreaks with Email/SMS alerts Automatically record, save, & playback discharge & recharge events

Abrir o catálogo na página 1
48V Battery Monitoring System: BDS-Pro - 2

System Composition The BDS-Pro connects directly to the battery system’s inter-cell connections. Measured data is processed by the MPU, the MPU can be configured for either TCP/IP to Centroid 2 software OR Modbus protocol. Option 1 - TCP/IP to Centroid: Data is sent from the MPU via TCP/IP to a PC which acts as a Server for all connected BMS systems. Client software installations can be installed on the same network for viewing on multiple PC’s. Option 2 - Modbus (TCP/IP or Serial): Data is sent from the MPU via Modbus protocol to a building management or SCADA system. Technical...

Abrir o catálogo na página 2

Todos os catálogos e folhetos técnicos Eagle Eye Power Solutions

  1. NERC PRC-005-02

    2 Páginas

  2. DCPS-Shelf-6KW

    2 Páginas

  3. DCPS-Shelf-9KW

    1 Páginas

  4. SC-1000

    2 Páginas

  5. SC-1500

    2 Páginas

  6. SC-2000

    2 Páginas

  7. RM-48-2K

    2 Páginas

  8. RM-48-3K

    2 Páginas

  9. RM-48-KA

    1 Páginas

  10. MIS-1000

    3 Páginas

  11. MIS-2000-series

    3 Páginas

  12. MIS-3000-series

    3 Páginas

  13. MIS-4000-series

    3 Páginas

  14. MIS-5000-series

    3 Páginas

  15. SIS-1000-series

    2 Páginas

  16. ENC-2000

    1 Páginas

  17. BMS-Series Catalog

    19 Páginas

  18. LB-AC-Digital

    1 Páginas

  19. BTM-Series

    1 Páginas

  20. BQMS

    2 Páginas

Catálogos arquivados

  1. HGD-3000

    1 Páginas

  2. DC Load Bank

    3 Páginas

  3. LB-1000

    1 Páginas

  4. SCR-SCRF

    1 Páginas

  5. AT10.1 - AT30

    1 Páginas

  6. SG-100M

    1 Páginas

  7. SG-1000

    1 Páginas

  8. SG-Ultra Max

    1 Páginas

  9. DC SLB-Series

    3 Páginas