

Excertos do catálogo

CONNECTION SYSTEMS Delphi Active Connection Systems (ACS) Delphi Active Connection Systems (ACS) are designed to meet high vibration and temperature resistance demands placed on connectors used in modern engines. The active secondary lock, active Connector Position Assurance (CPA), and housing seal enable advanced high-performance in high-temperature and highvibration environments. Delphi's first generation Active Connection Systems include highperformance two-, three-, four, and five-way serial systems. A second-generation two-way system with an updated terminal and housing is also now available for enhanced performance. The Active Connection Systems enable connectors to meet more stringent requirements for vibration and temperature resistance and updated safety-feature demands for engines. No device modifications are required to take advantage of the Delphi Active Connection Systems—the new generation terminal and connector housing fits the same mating parts as previous generations. The advanced ACS design features: Delphi Active Connection System 2-way Connector Combined radial and compression seal to eliminate vibration-related failures by stabilizing the position using radial and vertical forces in the sealing area Active Terminal System (ATS) that utilizes a Delphi-unique S-spring element that moves with vibrations to enhance high-vibration performance Active secondary lock, based on a modified Delphi ATS 2.8 terminal incorporating a special locking shoulder that prevents the terminal from being pulled out once it is inserted and the secondary lock is closed o This secondary lock also serves as the coding system and protects the housing seal CPA which remains fixed in its pre-position until the connector is plugged in o As the connector is plugged in, the mating part opens the pre-position, which allows the CPA to be closed Delphi Active Terminal System (ATS) Terminal with Special Locking Feature Enhanced vibration performance due to new housing seal design and use of ATS terminal Active secondary lock o Incorporates with the new locking shoulder to prevent the terminal from being pulled out once it is inserted and the secondary lock is closed Can only lock if the terminal is completely in the cavity o Provides protection against losing of the housing seal Active CPA helps ensure only correct connections are made by preventing closure until the connector is fully plugged in, helping minimize connection errors and to prevent accidental closures during delivery to enhance quality Different mechanical color/codings available Tel: (1) 248.813.2000 | www.delphi.com | © 2008 Delphi Corporation. All rights reserved. |
Abrir o catálogo na página 1
Delphi Active Connection Systems (ACS) Typical Applications The Delphi Active Connection Systems are ideally suited for use on sensors in the engine compartment area of any size vehicle. The connection systems can be used for in-line or device configurations and can also be used for pigtails when combined with the available male connector side. In addition to offering the Active Connection Systems, Delphi designs and manufacturers the following sensors: Knock sensors Cam and crank sensors Fluid temperature sensors Variable reluctance sensors Delphi can also supply customer-specific items....
Abrir o catálogo na página 2Todos os catálogos e folhetos técnicos Delphi Power Train
-
Friction, Discs & Drums
1028 Páginas
-
Engine Management, Ignition & Fuel
1460 Páginas
-
Turbochargers & DPF
114 Páginas
-
Filtration & DPF
709 Páginas
-
Air Conditioning & Engine Cooling
771 Páginas
-
Delphi Diesel Fuel Injectors
2 Páginas
-
Delphi 2-Step Valve Lift System
2 Páginas
-
Delphi Multec 20 GDi Fuel Injector
2 Páginas
-
Delphi HVAC Temperature Sensors
3 Páginas
-
Delphi IVT Battery Sensor
1 Páginas
-
Delphi Wide Range Oxygen Sensor
2 Páginas
-
Delphi Variable Reluctance Sensor
2 Páginas
-
Delphi Turbo Pressure Sensors
4 Páginas
-
Delphi Medium Pressure Sensors
4 Páginas
-
Delphi Low Pressure Sensors
3 Páginas
-
Delphi Fluid Temperature Sensors
2 Páginas
-
Delphi Flat Response Knock Sensor
2 Páginas
-
Delphi Air Temperature Sensors
3 Páginas
-
Delphi Switching Oxygen Sensors
2 Páginas
-
Delphi Mini-Switching Oxygen Sensors
2 Páginas
-
Delphi Particulate Matter Sensor
2 Páginas
-
Delphi Differential Pressure Sensor
2 Páginas
-
Delphi Ammonia Sensor
2 Páginas
-
Delphi Multi-Charge Ignition
2 Páginas
-
Delphi On/Off Transmission Actuators
2 Páginas
-
Delphi Waferized Connection System
2 Páginas
-
Delphi OCS Unsealed Connectors
3 Páginas
-
Delphi OCS Sealed Connectors
4 Páginas
-
srs overview
12 Páginas
-
Delphi Grounding Systems
2 Páginas
-
Delphi Compliant Pin Technology
2 Páginas
-
Delphi Wireless Device Charging
3 Páginas
-
Delphi Ethernet Connectivity
2 Páginas
-
Delphi Vehicle Sound Generator
1 Páginas
-
Delphi Battery Backed Sounder
1 Páginas
-
Delphi Smart Injector
2 Páginas
-
2013-2014 Heavy Duty & Off-Highway Vehicles
104 Páginas
-
Heavy Duty & Off-Road Vehicles
100 Páginas
-
Passenger Cars & Light Duty Vehicles
100 Páginas
-
Delphi Velocity? Tool Suite
2 Páginas
-
Ignition Products Catalog
24 Páginas
-
Delphi Solid State Relays (SSRs)
2 Páginas
-
Delphi Battery Monitoring Device
2 Páginas
-
Delphi Aluminum Cable Systems
3 Páginas
-
Delphi Hybrid Cluster
1 Páginas
-
Delphi FAKRA Connectors
2 Páginas
-
Delphi Data Connectivity Systems
4 Páginas
-
Product & Service Solutions
8 Páginas
-
Powertrain Cooling Systems
8 Páginas
-
Sealing out harsh environments
6 Páginas
-
Hybrid & Electric
8 Páginas
-
Delphi Connection Systems Overview
12 Páginas
Catálogos arquivados
-
E/E Architecture
8 Páginas
-
Delphi corporate brochure
24 Páginas
-
Evaporative Emissions
8 Páginas
-
Sensors
12 Páginas
-
Fuel Handling Systems
6 Páginas
-
Valve Train Systems
8 Páginas
-
Ignition Systems
8 Páginas
-
Exhaust Sensors
8 Páginas
-
Light Duty Diesel Injection Systems
8 Páginas
-
Gasoline Engine Management Systems
8 Páginas