Excertos do catálogo

Selection Guide l VACON® NXP Grid Converter r Reduce emissions and noise in ports and on ships with grid converter technology 10% fuel costs savings on shaft generator with VACON® NXP Grid Converter technology at M/V Bore Sea.
Abrir o catálogo na página 1
Reduce emissions and improve efficiency The limits of the worlds natural resources dominate our times, and the marine industry is taking on the same challenges as everybody else regarding energy usage. VACON® NXP Grid Converter technology helps ship owners and port authorities reduce fuel intake and improve efficiency. This will please investors and environmental legislators alike – after all, lower energy consumption equals lower costs. Ships require power when at sea and when docked in the harbour. Power is not only required to propel ships around the world, it also provides electricity to...
Abrir o catálogo na página 3
Shore supply solution with VACON® NXP Grid Converter Ships travel from port to port, sometimes stopping in a new country each day. Ports don’t all use the same electrical frequencies, and ships have historically used a fuel-driven onboard generator to provide electrical power while docked. This is costly though, and city councils and local residents are reluctant to tolerate the noise and poor air quality that is often associated with a busy city harbour. Many port authorities now prohibit, or at least strictly limit, the use of diesel generators while ships are docked. VACON® NXP Grid...
Abrir o catálogo na página 4
Case studies Clean power for the largest port in the world The port of Shanghai Location: Shanghai, China The Port of Shanghai is the busiest in the world in terms of cargo throughput, with nearly 170 large ships docking each day. Annual trade accounts for around ¼ of China’s total foreign trade. This activity inevitably puts a strain on the local environment, which is why the port uses a movable 2000 kVA shore supply system to supply electricity from the national grid to ships that are docked. VACON® NXP Grid Converter technology plays a key role in this design, ensuring 10 kV of shore...
Abrir o catálogo na página 5
Shaft generator solution with VACON® NXP Grid Converter The cruise liners and cargo ships of today tend to resemble mobile cities with vast infrastructures. They require a huge amount of electricity to maintain both their internal setup and the mechanical power that’s needed to travel around the world. Due to constant voltage and frequency requirements of the ship’s electrical network, the main engine operates at a fixed speed. For a number of years now, shaft generators have been used to supplement this with variable amounts of electrical power. With VACON® NXP Grid Converter technology,...
Abrir o catálogo na página 6
Case studies RoFlex® vessel with energy efficient shaft generator configuration WE Tech / M/V Bore Sea Location: Helsinki, Finland M/V Bore Sea was one of two RoFlex vessels ordered by Rorel Ltd to transport Airbus components. After the enforcement of the SEEMP in January 2013, WE Tech Solutions Oy developed a solution which optimized main propulsion machinery and improved energy efficiency. They chose a solution based on VACON® NXP Grid Converter technology. This is a system combining the shaft generator and the ship’s electrical network which allows for large variation to the main...
Abrir o catálogo na página 7
Ratings and dimensions VACON® NXP Grid Converter 465-800 V DC, Type Open, liquid-cooled, EMC Class T AC current Product code Power loss VACON® NXP Grid Converter 640-1100 V DC, Type Open, liquid-cooled, EMC Class T AC current Product code Power loss Power loss VACON® NXP Grid Converter 640-1200 VDC, IP00, liquid-cooled, EMC level T AC current Product code I TH = Thermal maximum continuous RMS current. Dimensioning can be done according to this current if the process does not require any overloadability or the process does not include any load variation or margin for overloadability. IL =...
Abrir o catálogo na página 8
VACON® NXP Grid Converter 380-500 V, Type Open/IP00 air-cooled, EMC Class T Low overload 110% / 40 °C Product code VACON® NXP Grid Converter 525-690 V, Type Open /IP00, air-cooled, EMC Class T Low overload 110% / 40 °C Product code Type code key GTCTA NX A AAAA V A 2 T 0 C S S A1 A2 00 00 00 + GTCTA NX A AAAA Grid Converter Product generation Module type A = Based on Active Front End Nominal current (low overload) 0004 =4 A 0520 = 520A, etc. Nominal mains voltage 5 = 380...500 V AC / 465-800 V DC 6 = 525...690 V AC / 640-1100 V DC 8 = 525...690 VAC / 640...1200 VDC (Only Ch6x) Control...
Abrir o catálogo na página 9
Shaft generator quick guide Generator type Generator side equipment Ship grid equipment Machine Power unit Filter Encoder Software Software Power unit Filter Isolation Asynchronous Permanent Magnet INU INU AFE dU/dt or none dU/dt or none SINE or LCL Yes Yes No Generator application ARFIFF03 Grid converter application ARFIFF03 Grid converter SINE (LCL in case of paralleling) Transformer Synchronous INU dU/dt or none Yes Shore supply quick guide Shore grid harmonics requirement Total current harmonics (THdi) Power unit Filter Software Power unit Filter Isolation Shore grid equipment Ship grid...
Abrir o catálogo na página 10
Danfoss Drives Danfoss Drives is a world leader in variable speed control of electric motors. We aim to prove to you that a better tomorrow is driven by drives. It is as simple and as ambitious as that. You can rely on us to share your goals. Striving for the best possible performance in your applications is our focus. We achieve this by providing the innovative products and application know-how required to optimize efficiency, enhance usability, and reduce complexity. From supplying individual drive components to planning and delivering complete drive systems; our experts are ready to...
Abrir o catálogo na página 12Todos os catálogos e folhetos técnicos Danfoss VLT Drives
-
Danfoss Drives VLT® Options
122 Páginas
-
VLT® Advanced Active Filter AAF 006
2 Páginas
-
VACON® 100
32 Páginas
-
VLT® Decentral Drive FCD 300
4 Páginas
-
Operating Instructions Profibus DP V
53 Páginas
-
Danfoss Drives – for your applications
24 Páginas
-
VACON® NXP DCGuard™
90 Páginas
-
Danfoss Drives Options Portfolio
122 Páginas
-
Danfoss Drives - for your applications
28 Páginas
-
VLT® OneGearDrive
40 Páginas
-
VLT® 12-pulse drive
2 Páginas
-
Danfoss Drives Fieldbus Solutions
12 Páginas
-
DrivePro® Life Cycleservices
8 Páginas
-
TP5001 Range
92 Páginas
-
VLT® DriveMotor: FCM 106 / FCP 106
12 Páginas
-
VLT® DriveMotor FCM 106
2 Páginas
-
VLT® DriveMotor FCM 300
2 Páginas
-
VLT® Power Option Sine-Wave Filter
2 Páginas
-
VLT® Power Option dU/dt Filter
2 Páginas
-
VLT® AutomationDrive
2 Páginas
-
VLT® AQUA Drive
2 Páginas
-
VLT® AQUA Drive
36 Páginas
-
VLT® drives up to 90 kW
2 Páginas
-
VLT® Panel Optimised Drives
2 Páginas
-
VLT® HVAC Drive
2 Páginas
-
VLT® HVAC Drive
40 Páginas
-
VLT® Refrigeration Drive FC 103
2 Páginas
-
VLT® Drives FC Series
16 Páginas
-
Danfoss VLT Drives
8 Páginas
-
Smart savings in automated systems
16 Páginas
-
Danfoss Drives
12 Páginas
-
VLT®
20 Páginas
-
VLT 2800
34 Páginas
-
VLT® Product Catalogue
60 Páginas
-
Danfoss VLT® Softstarter
8 Páginas
-
VLT® Decentral Drive FCD 302
2 Páginas
-
VLT® OneGearDrive
2 Páginas
-
Harmonics mitigation
16 Páginas
-
VLT® HVAC Drive
40 Páginas
-
MCC 101 Sine wave filters
2 Páginas
-
VLT® Decentral FCD 300
8 Páginas
-
VLT® DriveMotor FCM 300
8 Páginas
-
VLT® Micro Drive
8 Páginas
-
VLT® 2800 Series
5 Páginas
-
VLT® AQUA Drive FC 200
16 Páginas
-
VLT® HVAC Drive FC 100
20 Páginas