Optyma™
1 / 60Páginas

{{requestButtons}}

Excertos do catálogo

Optyma™ - 1

ENGINEERING TOMORROW Easy installation, easy service and reliable performance

Abrir o catálogo na página 1
Optyma™ - 4

Catalog Optyma™ condensing unit features Optyma™ condensing unit nomenclature / model no. Condenser size Electrical code OP- Application: L: Low H: Medium / High U: Universal Low / Medium / High Design: C: Air cooled condenser, Single fan, Recip J: Air cooled condenser, Slim Design, Recip G: Air cooled condenser, Twin fan, Recip N: Air cooled condenser, Slim Design, Scroll R: Air cooled condenser, Twin fan, Scroll Refrigerant: G:R134a H:R404A/R507 M: R22 Replacement Z: R404A/R507A/R134a* U: R404A/R134a/R507/R22 X: R448A/R449A/R404A/R507A/R134a Y: R448A/R449A/R404A/R507A Condenser size:-...

Abrir o catálogo na página 4
Optyma™ - 5

Optyma™ Indoor Condensing Units Tubing bends to minimize vibration Metal fan shroud and guard Quiet, efficient compressor Easy access service vales Large condenser for high ambient performance and efficiency Guard mounted motor

Abrir o catálogo na página 5
Optyma™ - 6

Catalog Optyma™ condensing unit R134a - MBP Fan Power consumption [W] at evap. temp. 20°F Test condition Electrical code Return gas temperature 65°F B: Compressor & fan(s) 115V, 1 ph, 60 Hz Subcooling 5°F N: Compressor & fan(s) 230V, 1 ph, 60 Hz HP rating in hundredths of HP, ie.: 033=1/3hp, (OP-UCGC0100U:0100=1hp) Power consumption referred at 90°F ambient temperature Version WA: Power cord WB: Power cord, Receiver WC: BX, Receiver WD: BX, Receiver, Low pressure control

Abrir o catálogo na página 6
Optyma™ - 7

Catalog Optyma™ condensing unit R134a - MBP (1) Dimensions (in) available on pages 29-36 (2) Wiring diagram available on pages 25-28 For spare parts, see pages 22-24

Abrir o catálogo na página 7
Optyma™ - 8

Catalog Optyma™ condensing unit R404A/R507 - MBP Fan Power consumption [W] at evap. temp. 20°F Test condition Electrical code Return gas temperature 65°F B: Compressor & fan(s) 115V, 1 ph, 60 Hz Subcooling 5°F N: Compressor & fan(s) 230V, 1 ph, 60 Hz HP rating in hundredths of HP, ie.: 033=1/3hp, (OP-UCGC0100U:0100=1hp) Power consumption referred at 90°F ambient temperature Version WA: Power cord WB: Power cord, Receiver WC: BX, Receiver WD: BX, Receiver, Low pressure control

Abrir o catálogo na página 8
Optyma™ - 9

Catalog Optyma™ condensing unit R404A/R507 - MBP (1) Dimensions (in) available on pages 29-36 (2) Wiring diagram available on pages 25-28 For spare parts, see pages 22-24

Abrir o catálogo na página 9
Optyma™ - 10

Catalog Optyma™ condensing unit R404A/R507 - MBP Test condition Electrical code Version Return gas temperature 65°F N: Compressor & fan(s) 230V, 1 ph, 60 Hz WE: BX, Receiver, Dual pressure control, Subcooling 5°F Q: Compressor 208-230V, 3ph, 60 Hz / Fan(s) 230V, 1ph, 60 Hz Fan cycling control, larger than 3 HP dual fan units use R: Compressor 460V, 3ph, 60 Hz / Fan(s) 230V, 1ph, 60 Hz KPU fan cycling control WF: WE + Filter drier, sight glass, solenoid valve with coil HP rating in hundredths of HP, ie.: 033=1/3hp, (OP-UCGC0100U:0100=1hp) Power consumption...

Abrir o catálogo na página 10
Optyma™ - 11

Catalog Optyma™ condensing unit R404A/R507 - MBP 6a (1) Dimensions (in) available on pages 29-36 (2) Wiring diagram available on pages 25-28 For spare parts, see pages 22-24

Abrir o catálogo na página 11
Optyma™ - 12

Catalog Optyma™ condensing unit R404A/R507 - MBP OP-HCZC0300U Power Power consumption consumption [W] at evap. [W] at evap. temp. 25°F temp. 20°F Test condition Electrical code Return gas temperature 65°F N: Compressor & fan(s) 230V, 1 ph, 60 Hz R: Compressor 460V, 3ph, 60 Hz / Fan(s) 230V, 1ph, 60 Hz HP rating in hundredths of HP, ie.: 033=1/3hp, (OP-UCGC0100U:0100=1hp) Power consumption referred at 90°F ambient temperature Version WE: BX, Receiver, Dual pressure control, Fan cycling control, larger than 3 HP dual fan units use KPU fan cycling control WF: WE + Filter drier,...

Abrir o catálogo na página 12
Optyma™ - 13

Catalog Optyma™ condensing unit R404A/R507 - MBP (1) Dimensions (in) available on pages 29-36 (2) Wiring diagram available on pages 25-28 For spare parts, see pages 22-24

Abrir o catálogo na página 13
Optyma™ - 14

Catalog Optyma™ condensing unit R404A/R507 - MBP WE OP-HGZC0900U Q Power Power consumption consumption [W] at evap. [W] at evap. temp. 25°F temp. 20°F Test condition Return gas temperature 65°F Subcooling 5°F HP rating in hundredths of HP, ie.: 033=1/3hp, (OP-UCGC0100U:0100=1hp) Power consumption referred at 90°F ambient temperature Version WE: BX, Receiver, Dual pressure control, Fan cycling control, larger than 3 HP dual fan units use KPU fan cycling control WF: WE + Filter drier, sight glass, solenoid valve with coil

Abrir o catálogo na página 14
Optyma™ - 15

Catalog Optyma™ condensing unit R404A/R507 - MBP (1) Dimensions (in) available on pages 29-36 (2) Wiring diagram available on pages 25-28 For spare parts, see pages 22-24

Abrir o catálogo na página 15
Optyma™ - 16

Catalog Optyma™ condensing unit R404A/R507 - LBP Fan Power consumption [W] at evap. Test condition Electrical code Return gas temperature 65°F B: Compressor & fan(s) 115V, 1 ph, 60 Hz Subcooling 5°F N: Compressor & fan(s) 230V, 1 ph, 60 Hz HP rating in hundredths of HP, ie.: 033=1/3hp, (OP-UCGC0100U:0100=1hp) Power consumption referred at 90°F ambient temperature Version WA: Power cord WB: Power cord, Receiver WC: BX, Receiver WD: BX, Receiver, Low pressure control

Abrir o catálogo na página 16
Optyma™ - 17

Catalog Optyma™ condensing unit R404A/R507 - LBP (1) Dimensions (in) available on pages 29-36 (2) Wiring diagram available on pages 25-28 For spare parts, see pages 22-24

Abrir o catálogo na página 17
Optyma™ - 18

Catalog Optyma™ condensing unit R404A/R507 - LBP Fan Power :onsumption [W] at evap. Test condition Electrical code Return gas temperature 65°F N: Compressor & fan(s) 230V, 1 ph, 60 Hz R: Compressor 460V, 3ph, 60 Hz / Fan(s) 230V, 1ph, 60 Hz HP rating in hundredths of HP, ie.: 033=1/3hp, (OP-UCGC0100U:0100=1hp) Power consumption referred at 90°F ambient temperature Version WE: BX, Receiver, Dual pressure control, Fan cycling control, larger than 3 HP dual fan units use KPU fan cycling control WF: WE + Filter drier, sight glass, solenoid valve with coil

Abrir o catálogo na página 18
Optyma™ - 19

Catalog Optyma™ condensing unit R404A/R507 - LBP (1) Dimensions (in) available on pages 29-36 (2) Wiring diagram available on pages 25-28 For spare parts, see pages 22-24

Abrir o catálogo na página 19

Todos os catálogos e folhetos técnicos Danfoss Industrial Automation

  1. Pressure switch RT

    17 Páginas

  2. Wind Power

    8 Páginas

  3. Danfoss Link™

    14 Páginas

  4. Electric Heating

    40 Páginas

  5. Supermarkets

    28 Páginas

  6. Type EV210A

    10 Páginas

  7. Switches overview

    2 Páginas

Catálogos arquivados