Grupo: Cubic
Excertos do catálogo

For Outdoor Particulate Matter Monitoring PM3006 System Cubic Sensor and Instrument Co.,Ltd www.gassensor.com.cn
Abrir o catálogo na página 1
1. Why Particulate Matter Measurement Is Important Particulate matter (PM) is a highly prevalent and impactful air pollutant around the world. PM10 Coarse particules Fine particules Upper respiratory tract Lower respiratory tract Very fine particules Alveolus Ultrafine particules Blood/Whole body Particulate matter refers to small size particles, they can enter the body, move into the airways and lungs, and even enter the bloodstream. High PM concentration cause serious acute health problems including asthma attacks, COPD exacerbations, heart attacks. In the long term explosure, it will...
Abrir o catálogo na página 2
2. Why Outdoor Particulate Matter Monitoring Is More Critical Outdoor air pollution is one of the world’s largest health and environmental problems. PM is a common and first proxy indicator for air pollution. Many countries have legislation that require ambient PM monitoring in cities and industrial & construction worksite. Without measurement there is no control. Intensive grid monitoring becomes more and more necessary. 2005 V.S. 2021 WHO Air Quality Guidelines(AQGs) With the growing awareness for air pollution for human beings, WHO strengthened the standards for PM concentration in air....
Abrir o catálogo na página 3
3. High-Stability Technology Applied for Outdoor PM Monitoring Beta Ray is widely used for outdoor applications due to its high accuracy and high stability in outdoor application scenarios, but the challenges of high cost, inconsecutive monitoring and regular maintenance required make Beta Ray device difficult to be implemented in large-scale. Advantage: High accuracy and sensitivity, not affected by ambient temperature and humidity Beta Ray device price is high Slow reaction Regular maintenance needed Large size, difficult to install
Abrir o catálogo na página 4
4. Emerged Reliable and Affordable Laser Scattering Technology for Outdoor PM Monitoring Real-time and continuous monitoring second by second Fast response Affordable for dense grid monitoring Capable for harsh outdoor working environment Light Scattering
Abrir o catálogo na página 5
5. How to Choose a Suitable Laser PM Sensor for Outdoor Application Real-time Network Monitoring • Equivalent to Bet Ray device • Capable for accurate measurement in different dust scenarios • Wider temperature range applicability • Anti-humidity capability
Abrir o catálogo na página 6
6. Popular Laser PM Sensors Used for Outdoor Monitoring in the Market There are 2 kinds of laser sensors in the market, indoor application designed laser PM sensor and especially designed outdoor application PM sensor. Indoor application designed sensor cannot be used for outdoors due to outdoor temperature, humidity, PM concentration conditions challenges, the especially designed laser PM sensor is irreplaceable for outdoor PM monitoring. Outdoor Applications Forest fire Indoor Applications Indoor application laser PM sensors in the market Industrial emission Bulk handing Especially...
Abrir o catálogo na página 7
7. Benchmark Test Between Outdoor Grade PM Sensor and Indoor Grade PM Sensor In order to fully demonstrate the benchmark test of the 2 kinds of laser PM sensors, we had Cubic PM3006 system as a representative for outdoor grade PM sensor and chose one of the indoor grade PM sensor in the market for the comparison test. PM2.5 and PM10 linear regression coefficient(R²)>0.8 against Beta Ray Device Auto Particulate Identification capability in different regions Wider temperature range applicability Anti-humidity capability **Outdoor Grade PM Sensor named as [C sensor], indoor grade PM sensor...
Abrir o catálogo na página 8
7. Benchmark Test Between Outdoor Grade PM Sensor and Indoor Grade PM Sensor • PM2.5 and PM10 Linear Regression Coefficient with MetOne Conclusion: ① C sensor linear regression coefficient (R²) >0.8 against MetOne for both PM2.5 and PM10. Conclusion: ② C sensor linear regression coefficient (R²) against MetOne is better than S sensor. C Sensor VS MetOne for PM10, 16 days in Ambient Air C Sensor VS MetOne for PM2.5, 16 days in Ambient Air S Sensor VS MetOne for PM10, 16 days in Ambient Air S Sensor PM10 μg/m³ S Sensor VS MetOne for PM2.5, 16 days in Ambient Air 200
Abrir o catálogo na página 9
7. Benchmark Test Between Outdoor Grade PM Sensor and Indoor Grade PM Sensor • Particle Identification Capability at Normal Temperature 25℃ Conclusion: ① PM1.0, PM2.5, PM10 of Cubic C sensors conform to GRIMM 11-A, while S sensors have no correlation with GRIMM 11-A Conclusion: ② Cubic C sensors Identification capability of PM1.0, PM2.5, PM10 is better than S sensors C sensor VS Grimm 11-A @25℃ Particle distribution @environment smoke + KCL
Abrir o catálogo na página 10
7. Benchmark Test Between Outdoor Grade PM Sensor and Indoor Grade PM Sensor • Particle Identification at High and Low Temperature Conclusion: ① PM1.0, PM2.5, PM10 of Cubic C sensors conform to GRIMM 11-A, while S sensors have no correlation with GRIMM 11-A. Conclusion: ② Cubic C sensors Identification capability of PM1.0, PM2.5, PM10 is better than S sensors. C sensor VS Grimm 11-A @-30℃ 250 200 150 100 50 0 Average C Sensor PM1.0 Average C Sensor PM2.5 Average C Sensor PM10 150 100 50 Averagr C sensor PM1.0 Averagr C sensor PM2.5 Averagr C sensor PM10 Average S Sensor PM1.0 Average S...
Abrir o catálogo na página 11
7. Benchmark Test Between Outdoor Grade PM Sensor and Indoor Grade PM Sensor • Measurement Performance at High Temperature 70℃ Conclusion: The performance of C sensors at 70℃ is excellent, while the consistency of S sensors at 70℃ is not good. C sensor PM1.0 Curve Time Time Time 1# C Sensor 4# C Sensor
Abrir o catálogo na página 12
7. Benchmark Test Between Outdoor Grade PM Sensor and Indoor Grade PM Sensor • Measurement Performance at Low Temperature -30℃ Conclusion: The performance of C sensors at -30℃ is excellent, while the consistency of S sensors at -30℃ is not good. C sensor PM2.5 Curve Time Time 1# C sensor Time Time 2# C sensor Time Time 4# C sensor S sensor PM1.0 Curve Concentration(μg/m³) C sensor PM10 Curve Concentration(μg/m³)
Abrir o catálogo na página 13
1# C Sensor 2# C Sensor 3# C Sensor 4# C Sensor 5# C Sensor 1# S Sensor 2# S Sensor 3# S Sensor 4# S Sensor 5# S Sensor 6# S Sensor 7. Benchmark Test Between Outdoor Grade PM Sensor and Indoor Grade PM Sensor • High Humidity Impact Test Conclusion: In high humidity environment, the performance of C sensors have low affection, while S sensors are greatly impacted.
Abrir o catálogo na página 14Todos os catálogos e folhetos técnicos Cubic Sensor and Instrument Co.
-
Cubic Ultrasonic Gas Metering Solutions
10 Páginas
-
Cubic Smart Water Metering Solution
6 Páginas
-
Cubic Gas Sensor Solutions Overview
7 Páginas
-
Cubic Automotive Gas Sensor Solution
23 Páginas
-
Cubic TDLAS CH4 Sensor
4 Páginas
-
Cubic Environmental Air Quality Sensors
16 Páginas
-
Cubic-IoT Smart Gas Sensor Solutions
2 Páginas
-
Gasboard-7500H-OPC
13 Páginas
-
Electrochemical CO Sensor ECO-5011
2 Páginas
-
TDLAS CH4 Sensor Gasboard-2500
2 Páginas
-
Air quality monitor AM7000_2021
1 Páginas
-
NDIR CO2 Sensor Module-CM1106H-NS
11 Páginas
-
NDIR CO2 Sensor Module-CM1106LS
18 Páginas
-
Dual Beam NDIR CO2 Sensor-CM1107T
11 Páginas
-
Laser Particle Sensor-PM2008M-M
22 Páginas
-
Dual Beam NDIR CO2 Sensor-CM1107BN
13 Páginas
-
PM2015-M Laser Particle Sensor Module
21 Páginas
-
Integrated Air Quality Sensor-AM1008W
16 Páginas
-
PM1006K LED Particle Sensor Module
12 Páginas
-
PM2009 Laser Particle Sensor Module
20 Páginas
-
Laser Particle Sensor-PM2012
19 Páginas
-
Test Instruction of AM4100-I
7 Páginas
-
Test Instruction of AM1008W
7 Páginas
-
Test Instruction of PM5000
7 Páginas
-
Test Instruction of PM1006
8 Páginas
-
Test Instruction of CM1107T
7 Páginas
-
Test Instruction of CM1107BN
8 Páginas
-
Test Instruction of PM3006T
7 Páginas
-
Test Instruction of PM2009
8 Páginas
-
Test Instruction of PM2008M-M
8 Páginas
-
Test Instruction of CM1106SH
8 Páginas
-
Test Instruction of CM1107
8 Páginas
-
Test Instruction of CM1106SL-N
8 Páginas
-
Test Instruction of CM1106S
8 Páginas
-
Test Instruction of CM1106LS
8 Páginas
-
Integrated Air Quality Sensor-AM4100-I
12 Páginas
-
Laser Particle Sensor-PM2008
21 Páginas
-
Laser Particle Sensor-PM2009
20 Páginas
-
Laser Particle Sensor-PM2105-M
20 Páginas
-
NDIR CO2 Sensor Module-CM1106S
18 Páginas
-
Low Power CO2 Sensor Module-CM1106SL-N
16 Páginas
-
Dual Beam NDIR CO2 Sensor Module-CM1107N
19 Páginas
-
Laser Particle Sensor Module-PM2008SE
24 Páginas
-
Ultrasonic Oxygen Sensor Gasboard8500
10 Páginas
-
mainstream NDIR ETCO2 sensor module
1 Páginas
-
Ultrasonic Technology Introduction
1 Páginas
-
Total Solution for Syngas Analyzer
13 Páginas
-
Industrial NIDR CO2 Sensor SRH
1 Páginas
-
Gas Sensor Line-up
1 Páginas
-
About Cubic
1 Páginas
-
Online Flue Gas Analyzer Gasboard 3000UV
12 Páginas
-
Online Flue Gas Analyzer Gasboard 3000
12 Páginas
-
CEMS Solution - Gasboard 9050
22 Páginas
-
NDIR CO2 Sensor Modules
7 Páginas
-
Gasboard-7020
4 Páginas
-
Gasboard-7500
7 Páginas
-
Mainstream ETC02 module
5 Páginas
-
Gasboard 3400P
5 Páginas
-
Portable GAS3100P Syngas Analyser
5 Páginas
-
Analyzer Gasboard 3800P
6 Páginas
-
LANDFILL APPLICATIONS
8 Páginas
-
Ultrasonic Gas Flow and Oxygen Sensor
11 Páginas
-
Laser Particle Sensor Features
1 Páginas
-
INFRARED (NDIR) CO2 GAS SENSOR
8 Páginas
Catálogos arquivados
-
Air quality monitor AM7000
11 Páginas
-
What is Ultrasonic Oxygen Sensor
2 Páginas
-
INFRARED METHANE (CH4 ) GAS SENSOR
8 Páginas
-
RHB Series
8 Páginas
-
Electrochemical (ECD) FIXED H2S GAS
6 Páginas
-
INFRARED (NDIR) PORTABLE Hydrogen
8 Páginas
-
Online biogas analyzer Gasboard 3200
1 Páginas
-
Ultrasonic Flow meter 7200
1 Páginas
-
Syngas portable analyzers
4 Páginas
-
Opacity meter
1 Páginas
-
Automobile exhaust gas analyzer
3 Páginas
-
Ultrasonic flow meter BF-3000
1 Páginas
-
Ultrasonic gas flow meter BF-3000
4 Páginas
-
Infrared handheld CH4 gas detector
2 Páginas
-
Infrared Carbon Dioxide gas sensor
4 Páginas
-
Infrared Methane gas sensor
3 Páginas