SPECIFICATION Product Name: NDIR CO2 Sensor Module Item No.: CM1106H-NS Version: V0.4 Date: May 26, 2020
Abrir o catálogo na página 1
NDIR CO2 Sensor Module CM1106H-NS Applications ▪ HVAC industry ▪ IAQ monitor ▪ Air purifier ▪ Automotive ▪ IoT devices ▪ Plant growth Description Infrared carbon dioxide CO2 sensor CM1106H-NS can be used to detect CO2 concentration of indoor air by adopting advanced non-dispersive infrared technology (NDIR). It is widely used in ventilation system, air conditioner, air purifier, IAQ monitor, agriculture, plant cultivation and cold-chain, etc. Features ▪ NDIR technology with independent intellectual property ▪ Temperature calibration within whole measurement range ▪ Long life span,...
Abrir o catálogo na página 3
Specifications Single Beam NDIR CO2 Sensor Specification Operating principle Non-dispersive infrared (NDIR) Measurement range Working temperature Working humidity Storage temperature Storage humidity Sampling frequency Time to first reading Power supply Ripple wave Working current Signal output Life span Maintenance-free for normal indoor application with Auto-calibration Note 1:Sensor is designed to measure in the range 0~2000ppm (PWM), 0-10000ppm (UART) with specified in the table. Nevertheless exposure to concentrations below 400ppm may result in incorrect operation of ABC algorithm and...
Abrir o catálogo na página 4
Dimensions and Connector 1. Dimensions (Unit mm, tolerance ±0.2 mm) Power supply input (4.5V-5.5V) Power supply output (3.3V/100mA) Power supply input (GND) Alarming (Reserved) RS485 control site (Reserved) Manual calibration
Abrir o catálogo na página 5
Typical Application Circuit Case1. (1) UART_TTL 3.3V output 5V level and 3.3V level conversion circuit
Abrir o catálogo na página 6
Description of Calibration Auto Calibration: Rough installing and influence of transportation might result in reducing of sensor measuring accuracy and baseline drift, sensor will correct the drift by the built-in self-correcting logic, and the auto baseline correction period is 24h+7 days. Powering on the sensor for 24 hours continuously, it will record the lowest CO2 concentration measurement value during the 24 hours, which will be regarded as baseline (400ppm) when sensor do auto calibration after the 24 hours working, and then the sensor will enter regular 7 days correction cycle, auto...
Abrir o catálogo na página 7
(1) Baud rate: 9600, Data Bits: 8, Stop Bits: 1, Parity: No, Flow Control: No (2) The data of this protocol are all hexadecimal data. For example, "46" is decimal [70]; (3) [xx] is single-byte data (unsigned, 0-255); double-byte data high byte first, low byte last; 2. UART protocol format Sending format of upper computer
Abrir o catálogo na página 8
4. Detail Description of UART Protocol 4.1 Read Measured Result of CO2 Send: 11 01 01 ED Response: 16 05 01 DF1- DF4 [CS] Function: Read measured result of CO2 (Unit: ppm) Note:CO2 measured result = DF1*256 + DF2 Example: Response: 16 05 01 02 58 00 00 8A Explanation: Hex is converted to decimal: 02 is 02; 58 is 88 CO2 concentration=02*256+88 = 600ppm 4.2 CO2 concentration value single point calibration Send:11 03 03 DF1 DF2 CS Response:16 01 03 E6 Function:CO2 concentration value single point calibration Note: 1. Single point calibration target value = DF1*256 + DF2. The unit is in ppm and...
Abrir o catálogo na página 9
After-Sales Services and Consultancy Cubic Sensor and Instrument Co., Ltd. Tel: +86 (0)27 81628827 Fax: +86 (0)27 81628821 Add: Fenghuang No.3 Road, Fenghuang Industrial Park, Eastlake Hi-tech Development Zone, Wuhan 430205, China E-mail: info@gassensor.com.cn
Abrir o catálogo na página 11Todos os catálogos e folhetos técnicos Cubic Sensor and Instrument Co.
-
Cubic Ultrasonic Gas Metering Solutions
10 Páginas
-
Cubic Smart Water Metering Solution
6 Páginas
-
Cubic Gas Sensor Solutions Overview
7 Páginas
-
Cubic Automotive Gas Sensor Solution
23 Páginas
-
Cubic TDLAS CH4 Sensor
4 Páginas
-
Cubic Environmental Air Quality Sensors
16 Páginas
-
Cubic-IoT Smart Gas Sensor Solutions
2 Páginas
-
Gasboard-7500H-OPC
13 Páginas
-
Electrochemical CO Sensor ECO-5011
2 Páginas
-
TDLAS CH4 Sensor Gasboard-2500
2 Páginas
-
Air quality monitor AM7000_2021
1 Páginas
-
NDIR CO2 Sensor Module-CM1106LS
18 Páginas
-
Dual Beam NDIR CO2 Sensor-CM1107T
11 Páginas
-
Laser Particle Sensor-PM2008M-M
22 Páginas
-
Dual Beam NDIR CO2 Sensor-CM1107BN
13 Páginas
-
PM2015-M Laser Particle Sensor Module
21 Páginas
-
Integrated Air Quality Sensor-AM1008W
16 Páginas
-
PM1006K LED Particle Sensor Module
12 Páginas
-
PM2009 Laser Particle Sensor Module
20 Páginas
-
Laser Particle Sensor-PM2012
19 Páginas
-
Test Instruction of AM4100-I
7 Páginas
-
Test Instruction of AM1008W
7 Páginas
-
Test Instruction of PM5000
7 Páginas
-
Test Instruction of PM1006
8 Páginas
-
Test Instruction of CM1107T
7 Páginas
-
Test Instruction of CM1107BN
8 Páginas
-
Test Instruction of PM3006T
7 Páginas
-
Test Instruction of PM2009
8 Páginas
-
Test Instruction of PM2008M-M
8 Páginas
-
Test Instruction of CM1106SH
8 Páginas
-
Test Instruction of CM1107
8 Páginas
-
Test Instruction of CM1106SL-N
8 Páginas
-
Test Instruction of CM1106S
8 Páginas
-
Test Instruction of CM1106LS
8 Páginas
-
Integrated Air Quality Sensor-AM4100-I
12 Páginas
-
Laser Particle Sensor-PM2008
21 Páginas
-
Laser Particle Sensor-PM2009
20 Páginas
-
Laser Particle Sensor-PM2105-M
20 Páginas
-
NDIR CO2 Sensor Module-CM1106S
18 Páginas
-
Low Power CO2 Sensor Module-CM1106SL-N
16 Páginas
-
Dual Beam NDIR CO2 Sensor Module-CM1107N
19 Páginas
-
Laser Particle Sensor Module-PM2008SE
24 Páginas
-
Ultrasonic Oxygen Sensor Gasboard8500
10 Páginas
-
mainstream NDIR ETCO2 sensor module
1 Páginas
-
Ultrasonic Technology Introduction
1 Páginas
-
Total Solution for Syngas Analyzer
13 Páginas
-
Industrial NIDR CO2 Sensor SRH
1 Páginas
-
Gas Sensor Line-up
1 Páginas
-
About Cubic
1 Páginas
-
Online Flue Gas Analyzer Gasboard 3000UV
12 Páginas
-
Online Flue Gas Analyzer Gasboard 3000
12 Páginas
-
CEMS Solution - Gasboard 9050
22 Páginas
-
NDIR CO2 Sensor Modules
7 Páginas
-
Gasboard-7020
4 Páginas
-
Gasboard-7500
7 Páginas
-
Mainstream ETC02 module
5 Páginas
-
Gasboard 3400P
5 Páginas
-
Portable GAS3100P Syngas Analyser
5 Páginas
-
Analyzer Gasboard 3800P
6 Páginas
-
LANDFILL APPLICATIONS
8 Páginas
-
Ultrasonic Gas Flow and Oxygen Sensor
11 Páginas
-
Laser Particle Sensor Features
1 Páginas
-
INFRARED (NDIR) CO2 GAS SENSOR
8 Páginas
Catálogos arquivados
-
Air quality monitor AM7000
11 Páginas
-
What is Ultrasonic Oxygen Sensor
2 Páginas
-
INFRARED METHANE (CH4 ) GAS SENSOR
8 Páginas
-
RHB Series
8 Páginas
-
Electrochemical (ECD) FIXED H2S GAS
6 Páginas
-
INFRARED (NDIR) PORTABLE Hydrogen
8 Páginas
-
Online biogas analyzer Gasboard 3200
1 Páginas
-
Ultrasonic Flow meter 7200
1 Páginas
-
Syngas portable analyzers
4 Páginas
-
Opacity meter
1 Páginas
-
Automobile exhaust gas analyzer
3 Páginas
-
Ultrasonic flow meter BF-3000
1 Páginas
-
Ultrasonic gas flow meter BF-3000
4 Páginas
-
Infrared handheld CH4 gas detector
2 Páginas
-
Infrared Carbon Dioxide gas sensor
4 Páginas
-
Infrared Methane gas sensor
3 Páginas