Grupo: Cubic
Excertos do catálogo

NDIR Carbon Dioxide Sensor for HVAC Application
Abrir o catálogo na página 1
IP Cubic ♦According to NIOSH (National Institute for Occupational Safety and Health), concentrations of 40000ppm or higher should be regarded as immediately dangerous to life and health. ♦Exposure to very high concentrations (eg. Exposure to 6% volume C02 for several minutes or 30% volume C02 for 20-30 seconds), has been linked to permanent heart damage. Concentrations greater than 10% are capable of causing loss of consciousness within 15 minutes or less. Exposure may lead to serious oxygen deprivation resulting in permanent brain damage, coma, even death Maximum allowed concentration...
Abrir o catálogo na página 2
CO2 sensor application in the HVAC system A ventilation system is a mechanical structure that is mainly used to control indoor(commonly homes and offices) air quality. Its main function is to introduce a constant supply of fresh air, usually from the outside. Managing the fresh air brought into the house and polluted air removed outside to realize proper ventilation rates is the key point. ●正文第一级内容(24号) of people are quite normal and maximum concentration CO2 levels above 1000ppm in a room with numbers may 正文第二级内容(20号) Ventilation system can use CO2 sensor to monitor the carbon ●...
Abrir o catálogo na página 3
CO2 sensor application in the HVAC system How do CO2 sensors help to balance the CO2 concentration between indoor and outside through its ventilation system performance? ●It is important to use an affordable and stable sensor technology to measure carbon dioxide 正文第二级内容(20号) concentration to determine the correct level of fresh air in a zone. NDIR CO2 sensors continuously monitor CO2 levels of indoor air, which providing an indication of the amount CO2 concentration ●正文第三级内容(20号) between indoor and outside. An
Abrir o catálogo na página 4
Benefits of CO2 measurement-based ventilation system Improved IAQ Poor indoor air quality may cause major health problems, such as allergies and respiratory diseases. When the CO2 levels in our house rise to an unacceptable level, ventilation system can control CO2 high level to the normal. Energy savings ● 正文第二级内容(20号) The energy saving for ventilation system can be achieved because CO2 sensor can help to provide ●正文第三级内容(20号) recommended ventilation rates to avoid excess heating, or cooling. Comfortable Normally, we spend approximately 60% of our time inside including home, office. So a...
Abrir o catálogo na página 5
NDIR CO2 sensor for HVAC system With adopting advanced non-dispersive infrared technology(NDIR), NDIR CO2 sensor can be used to detect CO2 concentration of indoor air, featuring excellent performance characteristics, including high accuracy and low power consumption.
Abrir o catálogo na página 6
Highlights of Cubic NDIR CO2 sensor The effectiveness of CO2 ventilation system relies upon the performance of CO2 sensors. A poor ventilation system can result in high CO2 level in the home or building. As ventilation system requirements become more strict, so do the performance of CO2 sensors. ◆High accuracy ● 正文第二级内容(20号) Temperature calibration within whole measurement range. ◆High stability Advanced auto-calibration at background. ◆Both single beam and dual beam available Suitable for lots of applications: IAQ monitor, ventilation system, air purifier, agricultural IoT, automotive,...
Abrir o catálogo na página 7Todos os catálogos e folhetos técnicos Cubic Sensor and Instrument Co.
-
Cubic Ultrasonic Gas Metering Solutions
10 Páginas
-
Cubic Smart Water Metering Solution
6 Páginas
-
Cubic Gas Sensor Solutions Overview
7 Páginas
-
Cubic Automotive Gas Sensor Solution
23 Páginas
-
Cubic TDLAS CH4 Sensor
4 Páginas
-
Cubic Environmental Air Quality Sensors
16 Páginas
-
Cubic-IoT Smart Gas Sensor Solutions
2 Páginas
-
Gasboard-7500H-OPC
13 Páginas
-
Electrochemical CO Sensor ECO-5011
2 Páginas
-
TDLAS CH4 Sensor Gasboard-2500
2 Páginas
-
Air quality monitor AM7000_2021
1 Páginas
-
NDIR CO2 Sensor Module-CM1106H-NS
11 Páginas
-
NDIR CO2 Sensor Module-CM1106LS
18 Páginas
-
Dual Beam NDIR CO2 Sensor-CM1107T
11 Páginas
-
Laser Particle Sensor-PM2008M-M
22 Páginas
-
Dual Beam NDIR CO2 Sensor-CM1107BN
13 Páginas
-
PM2015-M Laser Particle Sensor Module
21 Páginas
-
Integrated Air Quality Sensor-AM1008W
16 Páginas
-
PM1006K LED Particle Sensor Module
12 Páginas
-
PM2009 Laser Particle Sensor Module
20 Páginas
-
Laser Particle Sensor-PM2012
19 Páginas
-
Test Instruction of AM4100-I
7 Páginas
-
Test Instruction of AM1008W
7 Páginas
-
Test Instruction of PM5000
7 Páginas
-
Test Instruction of PM1006
8 Páginas
-
Test Instruction of CM1107T
7 Páginas
-
Test Instruction of CM1107BN
8 Páginas
-
Test Instruction of PM3006T
7 Páginas
-
Test Instruction of PM2009
8 Páginas
-
Test Instruction of PM2008M-M
8 Páginas
-
Test Instruction of CM1106SH
8 Páginas
-
Test Instruction of CM1107
8 Páginas
-
Test Instruction of CM1106SL-N
8 Páginas
-
Test Instruction of CM1106S
8 Páginas
-
Test Instruction of CM1106LS
8 Páginas
-
Integrated Air Quality Sensor-AM4100-I
12 Páginas
-
Laser Particle Sensor-PM2008
21 Páginas
-
Laser Particle Sensor-PM2009
20 Páginas
-
Laser Particle Sensor-PM2105-M
20 Páginas
-
NDIR CO2 Sensor Module-CM1106S
18 Páginas
-
Low Power CO2 Sensor Module-CM1106SL-N
16 Páginas
-
Dual Beam NDIR CO2 Sensor Module-CM1107N
19 Páginas
-
Laser Particle Sensor Module-PM2008SE
24 Páginas
-
Ultrasonic Oxygen Sensor Gasboard8500
10 Páginas
-
mainstream NDIR ETCO2 sensor module
1 Páginas
-
Ultrasonic Technology Introduction
1 Páginas
-
Total Solution for Syngas Analyzer
13 Páginas
-
Industrial NIDR CO2 Sensor SRH
1 Páginas
-
Gas Sensor Line-up
1 Páginas
-
About Cubic
1 Páginas
-
Online Flue Gas Analyzer Gasboard 3000UV
12 Páginas
-
Online Flue Gas Analyzer Gasboard 3000
12 Páginas
-
CEMS Solution - Gasboard 9050
22 Páginas
-
NDIR CO2 Sensor Modules
7 Páginas
-
Gasboard-7020
4 Páginas
-
Gasboard-7500
7 Páginas
-
Mainstream ETC02 module
5 Páginas
-
Gasboard 3400P
5 Páginas
-
Portable GAS3100P Syngas Analyser
5 Páginas
-
Analyzer Gasboard 3800P
6 Páginas
-
LANDFILL APPLICATIONS
8 Páginas
-
Ultrasonic Gas Flow and Oxygen Sensor
11 Páginas
-
Laser Particle Sensor Features
1 Páginas
-
INFRARED (NDIR) CO2 GAS SENSOR
8 Páginas
Catálogos arquivados
-
Air quality monitor AM7000
11 Páginas
-
What is Ultrasonic Oxygen Sensor
2 Páginas
-
INFRARED METHANE (CH4 ) GAS SENSOR
8 Páginas
-
RHB Series
8 Páginas
-
Electrochemical (ECD) FIXED H2S GAS
6 Páginas
-
INFRARED (NDIR) PORTABLE Hydrogen
8 Páginas
-
Online biogas analyzer Gasboard 3200
1 Páginas
-
Ultrasonic Flow meter 7200
1 Páginas
-
Syngas portable analyzers
4 Páginas
-
Opacity meter
1 Páginas
-
Automobile exhaust gas analyzer
3 Páginas
-
Ultrasonic flow meter BF-3000
1 Páginas
-
Ultrasonic gas flow meter BF-3000
4 Páginas
-
Infrared handheld CH4 gas detector
2 Páginas
-
Infrared Carbon Dioxide gas sensor
4 Páginas
-
Infrared Methane gas sensor
3 Páginas