Excertos do catálogo

INFRARED (NDIR) PORTABLE METHANE (CH4) GAS DETECTOR Wuhan Cubic Optoelectronics Co. , Ltd ADD : Fenghuang No.3 Road, Fenghuang Industrial Park,Eastlake Hi-tech Development Zone, Wuhan, 430205, China TEL : +86-27-87405251 FAX : +86-27-87401159 info@gassensor.c
Abrir o catálogo na página 1
Working principle CH4 gas is composed of different types of atoms have absorption spectrum in infrared range. Absorption intensity abides by Lamber-Beer’s Law. Basic working principle of NDIR sensor is as below, Inlet detector Light spectral filter Basic mathematical model : A majority of both organic and inorganic polyatomic gas have specific absorptive wavelength in infrared region. It observes Lambert-Beer Law formula I = I0e-kpl when infrared light is coming through. Light absorption intensity “i” can be described as i=I0-I= I0 (1- e- kpl). I0: intensity of incoming ray. I:...
Abrir o catálogo na página 2
■ This instrument is a perfect integration of worldleading technology (NDIR) and premium components. It can be used in measuring CH4 leakage detection. ■ It can be used in measuring CH4 concentration in the process of biogas generation. Meanwhile, it's able to detect biogas leakage.
Abrir o catálogo na página 3
Feature ﹒Independent intellectual property rights of infrared gas analysis technology ﹒Dual-range setting with high concentrations of methane gas leak detection and alarm function ﹒ High and low alarm points can be customized settings ﹒Air auto-zero calibration feature ﹒ Proliferation Sampling ﹒Fast response ﹒LED digital tube display real-time gas concentrations ﹒Rechargeable lithium battery Small size, sim
Abrir o catálogo na página 4
Application Portable CH4 detector is an ideal instrument with alarm function to detect the concentration of CH4, such as chemical industry, oil & gas storage, mine, metallurgy, liquefied gas station, spray paint, petroleum, fuel gas transport, as well as the leakage of nature gas. | | |
Abrir o catálogo na página 6
Alarming functions Alarm is able to set the alarm at any point, alarm value and set value displays the difference should not exceed ± 0.05% (the full range 0-10%) Alarm sound level intensity at a distance of not less than 75dB (A) in the distance of 1m. Optical signal visibility in the dark should not be less than
Abrir o catálogo na página 7
Instrument Configurations Remote controller
Abrir o catálogo na página 8Todos os catálogos e folhetos técnicos Cubic Sensor and Instrument Co.
-
Cubic Ultrasonic Gas Metering Solutions
10 Páginas
-
Cubic Smart Water Metering Solution
6 Páginas
-
Cubic Gas Sensor Solutions Overview
7 Páginas
-
Cubic Automotive Gas Sensor Solution
23 Páginas
-
Cubic TDLAS CH4 Sensor
4 Páginas
-
Cubic Environmental Air Quality Sensors
16 Páginas
-
Cubic-IoT Smart Gas Sensor Solutions
2 Páginas
-
Gasboard-7500H-OPC
13 Páginas
-
Electrochemical CO Sensor ECO-5011
2 Páginas
-
TDLAS CH4 Sensor Gasboard-2500
2 Páginas
-
Air quality monitor AM7000_2021
1 Páginas
-
NDIR CO2 Sensor Module-CM1106H-NS
11 Páginas
-
NDIR CO2 Sensor Module-CM1106LS
18 Páginas
-
Dual Beam NDIR CO2 Sensor-CM1107T
11 Páginas
-
Laser Particle Sensor-PM2008M-M
22 Páginas
-
Dual Beam NDIR CO2 Sensor-CM1107BN
13 Páginas
-
PM2015-M Laser Particle Sensor Module
21 Páginas
-
Integrated Air Quality Sensor-AM1008W
16 Páginas
-
PM1006K LED Particle Sensor Module
12 Páginas
-
PM2009 Laser Particle Sensor Module
20 Páginas
-
Laser Particle Sensor-PM2012
19 Páginas
-
Test Instruction of AM4100-I
7 Páginas
-
Test Instruction of AM1008W
7 Páginas
-
Test Instruction of PM5000
7 Páginas
-
Test Instruction of PM1006
8 Páginas
-
Test Instruction of CM1107T
7 Páginas
-
Test Instruction of CM1107BN
8 Páginas
-
Test Instruction of PM3006T
7 Páginas
-
Test Instruction of PM2009
8 Páginas
-
Test Instruction of PM2008M-M
8 Páginas
-
Test Instruction of CM1106SH
8 Páginas
-
Test Instruction of CM1107
8 Páginas
-
Test Instruction of CM1106SL-N
8 Páginas
-
Test Instruction of CM1106S
8 Páginas
-
Test Instruction of CM1106LS
8 Páginas
-
Integrated Air Quality Sensor-AM4100-I
12 Páginas
-
Laser Particle Sensor-PM2008
21 Páginas
-
Laser Particle Sensor-PM2009
20 Páginas
-
Laser Particle Sensor-PM2105-M
20 Páginas
-
NDIR CO2 Sensor Module-CM1106S
18 Páginas
-
Low Power CO2 Sensor Module-CM1106SL-N
16 Páginas
-
Dual Beam NDIR CO2 Sensor Module-CM1107N
19 Páginas
-
Laser Particle Sensor Module-PM2008SE
24 Páginas
-
Ultrasonic Oxygen Sensor Gasboard8500
10 Páginas
-
mainstream NDIR ETCO2 sensor module
1 Páginas
-
Ultrasonic Technology Introduction
1 Páginas
-
Total Solution for Syngas Analyzer
13 Páginas
-
Industrial NIDR CO2 Sensor SRH
1 Páginas
-
Gas Sensor Line-up
1 Páginas
-
About Cubic
1 Páginas
-
Online Flue Gas Analyzer Gasboard 3000UV
12 Páginas
-
Online Flue Gas Analyzer Gasboard 3000
12 Páginas
-
CEMS Solution - Gasboard 9050
22 Páginas
-
NDIR CO2 Sensor Modules
7 Páginas
-
Gasboard-7020
4 Páginas
-
Gasboard-7500
7 Páginas
-
Mainstream ETC02 module
5 Páginas
-
Gasboard 3400P
5 Páginas
-
Portable GAS3100P Syngas Analyser
5 Páginas
-
Analyzer Gasboard 3800P
6 Páginas
-
LANDFILL APPLICATIONS
8 Páginas
-
Ultrasonic Gas Flow and Oxygen Sensor
11 Páginas
-
Laser Particle Sensor Features
1 Páginas
-
INFRARED (NDIR) CO2 GAS SENSOR
8 Páginas
Catálogos arquivados
-
Air quality monitor AM7000
11 Páginas
-
What is Ultrasonic Oxygen Sensor
2 Páginas
-
INFRARED METHANE (CH4 ) GAS SENSOR
8 Páginas
-
RHB Series
8 Páginas
-
Electrochemical (ECD) FIXED H2S GAS
6 Páginas
-
INFRARED (NDIR) PORTABLE Hydrogen
8 Páginas
-
Online biogas analyzer Gasboard 3200
1 Páginas
-
Ultrasonic Flow meter 7200
1 Páginas
-
Syngas portable analyzers
4 Páginas
-
Opacity meter
1 Páginas
-
Automobile exhaust gas analyzer
3 Páginas
-
Ultrasonic flow meter BF-3000
1 Páginas
-
Ultrasonic gas flow meter BF-3000
4 Páginas
-
Infrared handheld CH4 gas detector
2 Páginas
-
Infrared Carbon Dioxide gas sensor
4 Páginas
-
Infrared Methane gas sensor
3 Páginas