H2O-CPR
1 / 4Páginas

{{requestButtons}}

Excertos do catálogo

H2O-CPR - 1

H2O-CPR PRESSURE FEED SPRAY GUN PRODUCT INFORMATION The H2O-CPR gun comes equipped with both a pressure reduced air cap 23-2101 and a HVLP air cap 23-1301 for areas requiring HVLP compliance. 23-2101 - consumes 11 cfm at 29 psi gun inlet. 23-1301 - consumes 13.5 cfm at 29 psi gun inlet. 23-2101 pressure reduced air caps can be used with the 0.8 mm - 1.7 mm fluid orifices listed below. 23-1301 HVLP air caps can be used with the full range of fluid orifices listed below. HVLP/PRESSURE REDUCED AIR CAP AND FLUID NOZZLE CHART MODEL NO. *MAX GUN FLUID TIP INLET PRESS. RANGE FOR HVLP AVAILABLE FLUID NOZZLES TIPS 33-0208 33-0210 0.8 - 1.7 29* 11 33-0212 Included 33-0213 H2O-CPR 60-1504 (S) 33-0214 Included 33-0215 23-1301 Included 33-0217 0.8 - 2.2 29* 13.5 (HVLP) 33-0219 33-0222 Actual fluid nozzle and air cap combinations are determined by application (see application chart page 4) *Note: Air cap test gages are available to confirm HVLP compliance. *Gun inlet pressures may vary as required by application 23-2101 CPR (Pressure Reduced) Coating Atomization Technologies 337 South Arthur Avenue, Louisville CO 80027 Phone: 888.820.4498, Fax: 303.438.5708 www.spraycat.com

Abrir o catálogo na página 1
H2O-CPR - 2

Operation and Maintenance Instructions for Spray Guns Operation 1. Connect air supply hose at handle of gun. 2. Connect a pressurized fluid supply to the gun fluid inlet. 3. Fluid flow can be controlled using the fluid control knob, this restricts flow by limiting needle travel. It is best to control fluid flow by proper selection of fluid orifice size and use the fluid control knob to “fine tune flow rate”. 4. Fan width can be adjusted using the fan control knob. Turning the knob clockwise narrows the fan. Maintenance IMPORTANT! Routine cleaning and maintenance is essential to insure...

Abrir o catálogo na página 2
H2O-CPR - 3

**See air cap selection chart on page 1 indicates part included in repair kit # 10-106

Abrir o catálogo na página 3
H2O-CPR - 4

H2O-CPR Smart Pack Includes: 98-0104 3/8” Socket Air Caps and Needles Shown on Page 1 H2O-CPR-303SS-R2 Includes: 51-303SS 1 QT Stainless Steel Pressure Cup Air Caps and Needles Shown on Page 1 H2O-CPR-PPS-R2 Includes: 91-460 950 mL 3M™ PPS™ Pressure Cup 91-462 Lids and Liners (Available in 25 Pack) 98-0113 Gun Cleaning Brush Air Caps and Needles Shown on Page 1

Abrir o catálogo na página 4

Todos os catálogos e folhetos técnicos C.A.Technologies

  1. H2O-CPR-G

    4 Páginas

  2. Lynx 100CVT

    4 Páginas

  3. AutoCAT 100CVT

    4 Páginas

  4. Tomahawk

    4 Páginas

  5. Tomcat 100C

    4 Páginas

  6. Jaguar 100C

    4 Páginas

  7. Panther 100G

    4 Páginas

  8. C14 AAA

    8 Páginas

  9. 14:1 AAA PC

    2 Páginas

  10. AutoCAT 100C

    4 Páginas

  11. AutoCAT 300H

    4 Páginas

  12. AutoCAT 100H

    4 Páginas

  13. AM CPR

    4 Páginas

  14. CATALYZER

    12 Páginas

  15. AAA Line

    2 Páginas

  16. CAT-X

    2 Páginas

  17. CPR-G

    4 Páginas

  18. 51-130 & 51-132

    2 Páginas

  19. 51-303

    2 Páginas

  20. Lynx 300C (L300C)

    4 Páginas

  21. Lynx 200C (L200C)

    4 Páginas

  22. Lynx 100C (L100C)

    4 Páginas

  23. GO System

    2 Páginas

  24. 2013 Catalog

    47 Páginas

Catálogos arquivados

  1. Catalog 2007

    35 Páginas