8222
1 / 8Páginas

Excertos do catálogo

8222 - 1

Conductivity meter • Analog 4…20 mA output • Universal process connection • Three cell constants for covering a wide measuring range • Temperature compensated measurement Type 8222 neutrino can be combined with… Type 8611 eCONTROL Universal controller Type 8619 multiCELL Transmitter/Controller The Bürkert neutrino meter Type 8222 is a compact device designed for measuring the conductivity of fluids. The conductivity meter consists of a sensor plugged-in and pined to an enclosure with cover, containing the electronic module. The sensor holder comprises a cell with two electrodes and a Pt1000 temperature sensor. The sensor itself is available with three different cell constants C, these with C = 0.01 or 0.1 are fitted with stainless steel electrodes and this with C = 1.0 is fitted with graphite electrodes. The neutrino conductivity meter Type 8222 is available with one 2-wire 4…20 mA current output and with two different connections: either a G 1½ union nut for adaptor with G 1½ external threaded sensor connection or a G ¾ threaded holder for screwing into an adaptor with G ¾ internal thread sensor connection. Type 8693 Process controller Type 8802 ELEMENT Control valve system Type S022 Insertion Adapter/ Fitting for ELEMENT analytical devices Technical data (Pipe + conductivity meter) Pipe diameter DN25…DN110 (DN < 25 with reduction) Conductivity measurement Measuring range 0.05 µS/cm…10 mS/cm Measurement deviation ±3 % of measured value Temperature measurement Measuring range -20…+100 °C (-4…+212 °F) Measurement deviation ±1 °C (1.8 °F) Temperature compensation according to a predefined graph (none, NaCl, ultra pure water), selectable via a switch Fluid temperature 0…+50 °C (+32…+122 °F) with G 1½ PVC connection nut with G 1½ PVDF connection nut -20…+100 °C (-4…+212 °F) restricted by the used adap(on request) tor; restriction with adaptor S022 in: - PVC: 0…+50 °C (+32…+122 °F) - PP: 0…+80 °C (+32…+176 °F) - Metal: -20…+100 °C (-4…+212 °F) with G ¾ external threaded connection Fluid pressure max Environment Ambient temperature Relative humidity -20…+100 °C (-4…+212 °F) restricted by the used adaptor; restriction with adaptor S022 in: - PVC: 0…+50 °C (+32…+122 °F) - PVDF: 0…+100 °C (+32…+212 °F) - Metal: -20…+100 °C (-4…+212 °F) PN16 (232 PSI) (see pressure / temperature chart) -10…+60 °C (+14…+140 °F) (operating and storage) ≤ 85 %, without condensation The electronics of Type 8222 conver

Abrir o catálogo na página 1
8222 - 2

8222 ELEMENT neutrino Materials view General data Compatibility Materials Housing Cover Seals Fixed connector Nut Wetted part materials   Temperature sensor Conductivity electrodes Temperature sensor Electrical connections Recommended connection cable for terminal strip Solid H05(07) V-U Flexible H05(07) V-K With wire end ferrule With plastic collar ferrule Diameter Electrical data Power supply Characteristics of the power source (not provided) of UL recognized devices Any pipe which are fitted out with Bürkert adaptor S022 (see separate data sheet) See exploded view, opposite Stainless...

Abrir o catálogo na página 2
8222 - 3

8222 ELEMENT neutrino Pressure/temperature chart Application range of a 8222 ELEMENT neutrino conductivity meter: A: with PVDF nut (on request) or G ¾ external threaded connection B: with PVC nut The measures have been made at an ambient temperature of 60 °C. Application range of a 8222 ELEMENT neutrino conductivity meter • with PVDF nut (on request) with S022 adaptor Pressure (bar) • with PVC nut with S022 adaptor PVC • with G ¾ threaded connection with S022 adaptor 16

Abrir o catálogo na página 3
8222 - 4

8222 ELEMENT neutrino Principle of operation Conductivity is defined as the ability of a solution to conduct electrical current. The load carriers are ions (E.G. dissolved salt or acids). In order to measure conductivity 2 electrodes are used which are set at a fixed distance apart and with a known specified surface. An AC voltage source is connected to the electrodes. The measured current is a direct function of the conductivity of the solution. The conductivity meter is a two-wire device, which requires a power supply of 12…36 V DC. The conductivity meter can be fitted with 3 different...

Abrir o catálogo na página 4
8222 - 5

8222 ELEMENT neutrino Dimensions [mm] of conductivity meter Type 8222 with a G 1½ union connection nut 87 86.5 with a G ¾ external threaded connection 86.5 C=1 Threading dimensions plan (for installation of the conductivity meter with a G¾" external threaded connection) Ø28H8 G3/4"

Abrir o catálogo na página 5
8222 - 6

8222 ELEMENT neutrino Ordering information for compact conductivity meter, Type 8222 A complete compact ELEMENT neutrino conductivity meter, Type 8222, consists of:   - compact ELEMENT neutrino conductivity meter, Type 8222, with a G 1½ union connection nut and a Bürkert S022 Insertion adaptor with a a G 1½ external threaded sensor connection. The following information is necessary for the selection of a complete device: •Article no. of the desired 8222 ELEMENT neutrino conductivity meter with a G 1½ union connection nut (see ordering chart on p. 7) •Article no. of the selected S022...

Abrir o catálogo na página 6
8222 - 7

8222 ELEMENT neutrino Ordering chart for compact conductivity meter Type 8222 Specifications Compact conductivity meter with a G 1½ union connection nut Electrical connection 5 pin M12 male fixed connector Cable gland 5 pin M12 male fixed connector Cable gland 5 pin M12 male fixed connector Cable gland Compact conductivity meter with a G ¾ external threaded connection 5 pin M12 male fixed connector Cable gland 5 pin M12 male fixed connector Cable gland 5 pin M12 male fixed connector Cable gland

Abrir o catálogo na página 7

Todos os catálogos e folhetos técnicos BÜRKERT FLUID CONTROL SYSTEMS

  1. Type 0121

    16 Páginas

  2. Type 6240

    26 Páginas

  3. Type 8020

    10 Páginas

  4. Type 8026

    12 Páginas

  5. Type 8605

    13 Páginas

  6. Type 8692

    18 Páginas

  7. Type 5470

    15 Páginas

  8. 8041

    10 Páginas

  9. Type 0498

    6 Páginas

  10. Type 8081

    9 Páginas

  11. Type 2300

    32 Páginas

  12. Type 8012

    21 Páginas

  13. Type 8110

    11 Páginas

  14. Type 8010

    14 Páginas

  15. Type 8137

    12 Páginas

  16. Typ 8804

    12 Páginas

  17. Solenoid Valves

    31 Páginas

  18. 6240

    11 Páginas

  19. Type 0301

    4 Páginas

  20. Type 0201

    4 Páginas

  21. Type 0300

    6 Páginas

  22. Type 0200

    6 Páginas

  23. Type 0131

    4 Páginas

  24. Type 0142

    4 Páginas

  25. Type 0117

    3 Páginas

  26. Type 0293

    3 Páginas

  27. AirLINE SP

    2 Páginas

  28. Dosing Systems

    4 Páginas

  29. CUT Product Line

    9 Páginas

  30. Cooling Towers

    2 Páginas

  31. MicroFluidics

    2 Páginas

  32. Fuel Cell Tech

    2 Páginas

  33. Robot Welding

    2 Páginas

  34. Plastic Extruding

    2 Páginas

  35. Flyer Cooking

    2 Páginas

  36. Injection Molding

    2 Páginas

  37. Heat Exchanger

    2 Páginas

  38. Clean Steam

    2 Páginas

  39. Food and Beverage

    32 Páginas

  40. Company profile

    15 Páginas

  41. steam products

    16 Páginas

Catálogos arquivados

  1. Type 6281

    21 Páginas

  2. 6281

    13 Páginas