Burst Alert® Sensors For immediate notification of a pressure relief event Visit our website for the most complete, up-to-date information

Abrir o catálogo na página 1
Burst Alert® Sensor - 2

Burst Alert® Sensors for Rupture Disks and Other Devices Sensor Type BAS+TM Armored: ABAS+TM Features • Polyimide film • Tantalum conductor wire • Dual path conductor • Reconnect StopsTM • Wide conductor separation Burst Pressures See Table 1 Note: Two Reconnect StopsTM are seen at the breaking ends of the tantalum conductor wire run into the gasket. The stops provide electrical insulation to minimize risk of sensor reconnection after a pressure relief event. Use with the following rupture disk type Sure-Saf Order as EC-Alert Sensor: ECR, ECV, ECT, V/ECR (see table 1) Forward acting...

Abrir o catálogo na página 2
Burst Alert® Sensor - 3

Burst Alert® Sensors Sensor Type Features • Polyimide film DASTM TM • Tantalum conductor wire DASS • Dual path conductor Armored: • Domed to accommodate TM ADAS disk dome TM ADASS Use with the following rupture disk type XT, XB, XN-85S and XN disks 4 inches (100mm) and larger used in NX-7R or NXV-7R safety heads. B, BV, Tension D, DV, XN-85 disks used in special reduced height loaded disks safety heads that do not enclose the disk dome. Atmospheric vent type disks: AV, AVV, AVE, AVEL Burst Pressures The response pressure capability of the DAS family of sensors matches the minimum burst...

Abrir o catálogo na página 3
Burst Alert® Sensor - 4

Operation / Electrical Information Burst Alert Sensors operate in a “normally closed” electrical circuit with a polymer membrane supporting its electrical conducting circuit. When the pressure event (disk rupture / valve opening) occurs, the flow (gas or liquid) breaks the tantalum electrical conductor located on the polymer membrane. The electrical status of the sensor changes to “normally open.” The recommended maximum operating limits for Burst Alert Sensors is a current of 500mA, maximum voltage 24 VDC; satisfactory operation can be obtained at a few milliamperes current. Gaskets:...

Abrir o catálogo na página 4

Todos os catálogos e folhetos técnicos BS&B SAFETY SYSTEMS

  1. Type D

    8 Páginas

  2. Rupture Disk

    12 Páginas

  3. Corporate Profile

    20 Páginas

  4. SURE-SAF? System

    4 Páginas

  5. ECO-SAF? System

    8 Páginas

  6. BIO-SAF? System

    16 Páginas

  7. SmartSystem

    4 Páginas

  8. MRB series

    1 Páginas

  9. SIGMA, SIGMA EXL

    4 Páginas

  10. EXPLOSION VENTING

    4 Páginas

  11. AVB

    2 Páginas

  12. Nu-Saf Plus

    8 Páginas

  13. Type B

    8 Páginas

  14. The STA-SAF System

    12 Páginas