PULSE ISOLATOR
1 / 4Páginas

{{requestButtons}}

Excertos do catálogo

PULSE ISOLATOR - 1

TECHNICAL DATA SHEET PULSE ISOLATOR SAFETY ACCESSORIE ATEX Interface for level switches - ATEX- IECEx- SIL 3 Technical characteristics : • 2 channels - 2 outputs • Cable error detection. • Up to SIL 3 in accordance with CEI 61508 • Input from area 0 (Area 20), safe in installation or in Area 2. • Galvanic isolation of 3 ports of the circuit, input / output / power . • Installation on a DIN rail, with or without Power Bus. • Power supply 24 Vdc (18 to 30 Vdc) • Pulse isolator with safety barrier for the supply of NAMUR sensors installed in the hazardous area • Pulse isolator with safety barrier for the detection of mechanical contacts installed in the hazardous area. • One input signal can be used on two separate outputs Mounting: • Mounted vertically or horizontally on a DIN rail up to 84 channels per meter can be mounted Certifications: • ATEX, IEC Ex, DNV, INMETRO, NEPSI, GOST, TRCU, TCCExEE, Korean Register, CCOE Indian, Rostehnadzor, • TUV SIL Functional Safety Certificate ATMI - ZA de I'observatoire - 2, avenue des Bosquets - 78180 MONTIGNY LE BRETONNEUX - FRANCE Tel. : +33 (0)1 61 37 35 60 - Fax : +33 (0)1 61 37 35 69 - @mail: sales@atmi.fr web site: www.atmi.fr

Abrir o catálogo na página 1
PULSE ISOLATOR - 2

PULSE ISOLATOR TECHNICAL DATA SHEET SIL 3 Switch/Proximity Detector Repeater, Relay Ouput Din-Rail Models D5030S, D5030S Characteristics Technical data: Gimril OuscrFplian: The sngle and dual channel SwttchTPmximrty Detector Repealer, D5030S and 050300 module is a unit suitable for applications requiring SIL 3 level (according to IEC 61508:2010 Ed. 2) in safety related systems for high risk industries. The unit can ba configured lor switch or proximity detector (EN60947-5-6. NAMUR). NO or NC end lor NE or ND SPST (D5D30D) or SPOT (D503OS) relay output contact Each channel enables a Safe...

Abrir o catálogo na página 2
PULSE ISOLATOR - 3

PULSE ISOLATOR TECHNICAL DATA SHEET PARAMETERS : Maximum External Parameters Safety description Groupe Cenelec FUNCTION DIAGRAM: HAZARDOUS AREA ZONE 0 (ZONE 20) GROUP IIC,HAZARDOUS LOCATIONS CLASS I, DIVISION 1, GROUPS A, B, C, D,CLASS II, DIVISION 1, GROUPS E, F, G, CLASS III, DIVISION 1,CLASS I, ZONE 0, GROUP IIC SAFE AREA, ZONE 2 GROUP IIC T4,NON HAZARDOUS LOCATIONS, CLASS I, DIVISION 2, GROUPS A, B, C, D T-Code T4, CLASS I, ZONE 2, GROUP IIC T4 ATMI – ZA de l’observatoire - 2, avenue des Bosquets - 78180 MONTIGNY LE BRETONNEUX - FRANCE Tél. : +33 (0)1 61 37 35 60 - Fax : +33 (0)1 61 37...

Abrir o catálogo na página 3
PULSE ISOLATOR - 4

PULSE ISOLATOR HAZARDOUS AREA ZONE 0 (ZONE 20) GROUP IIC, HAZARDOUS LOCATIONS CLASS I, DIVISION 1, GROUPS A, B, C, D, CLASS II, DIVISION 1, GROUPS E, F, G, CLASS III, DIVISION 1, CLASS I, ZONE 0, GROUP IIC TECHNICAL DATA SHEET SAFE AREA, ZONE 2 GROUP IIC T4, NON HAZARDOUS LOCATIONS, CLASS I, DIVISION 2, GROUPS A, B, C, D T-Code T4, CLASS I, ZONE 2, GROUP IIC T4 Relay contact shown in de-energized position. Contacts relais montrés en position non alimenté. Terminals 1-2 and 3-4 open. Contact ouvert bornes 1-2 et 3-4 SAFE AREA, ZONE 2 GROUP IIC T4, NON HAZARDOUS LOCATIONS, CLASS I, DIVISION...

Abrir o catálogo na página 4

Todos os catálogos e folhetos técnicos ATMI

  1. SOLIBA PRA

    2 Páginas

  2. SOLIBA PRP

    2 Páginas

  3. SOLIBA M

    2 Páginas

  4. SOLIBA Msmall

    2 Páginas

  5. FIX-CAB

    1 Páginas

  6. PIEZO ST

    1 Páginas

  7. Cable clamps

    1 Páginas

  8. AQUA MEDIUM

    2 Páginas

  9. TUBA 125C

    2 Páginas

  10. SOLIBA EX GP

    2 Páginas

  11. SOLIBA EX P

    2 Páginas

  12. SOLIBA

    2 Páginas

  13. AQUA MEDIUM EP

    2 Páginas

  14. BIP STOP

    2 Páginas

  15. AQUA XL

    2 Páginas

  16. SOBA HR HY

    2 Páginas

  17. SOBA SMALL

    2 Páginas

  18. PIEZO AS

    1 Páginas

  19. SOLIBA SPECIAL

    1 Páginas

  20. CABLE CLAMP

    1 Páginas

  21. ATEX Certificate

    4 Páginas

  22. ACS Certificate

    1 Páginas

Catálogos arquivados

  1. ATMI Brochure

    6 Páginas