Basco Engineered Shell & Tube Heat Exchangers
1 / 12Páginas

{{requestButtons}}

Excertos do catálogo

Basco Engineered Shell & Tube Heat Exchangers - 1

tascabile 2010 home 146x190.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:19.00pt "Microsoft Sans Serif", sans-serif; } .font1 { font:34.00pt "Microsoft Sans Serif", sans-serif; } .font2 { font:13.00pt "Times New Roman", serif; } .font3 { font:106.00pt "Times New Roman", serif; } BSCO BASCO ENGINEERED SHELL & TUBE HEAT EXCHANGERS 1 Heat Transfer ...world leaders in heat transfer technology

Abrir o catálogo na página 1
Basco Engineered Shell & Tube Heat Exchangers - 2

tascabile 2010 home 146x190.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:15.00pt "Arial Black", sans-serif; } .font1 { font:8.00pt "Microsoft Sans Serif", sans-serif; } .font2 { font:9.00pt "Microsoft Sans Serif", sans-serif; } .font3 { font:11.00pt "Microsoft Sans Serif", sans-serif; } .font4 { font:26.00pt "Palatino Linotype", serif; } .font5 { font:32.00pt "Palatino Linotype", serif; } .font6 { font:15.00pt "Times New Roman", serif; } .font7 { font:19.00pt "Times New Roman", serif; } API Heat Transfer is your one source for custom engineered shell &...

Abrir o catálogo na página 2
Basco Engineered Shell & Tube Heat Exchangers - 3

tascabile 2010 home 146x190.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:8.00pt "Arial", sans-serif; } .font1 { font:9.00pt "Arial", sans-serif; } .font2 { font:12.00pt "Arial", sans-serif; } .font3 { font:17.00pt "Arial", sans-serif; } .font4 { font:13.00pt "Franklin Gothic Medium", sans-serif; } .font5 { font:18.00pt "Times New Roman", serif; } Manufacturing API Basco is located in Buffalo, NY within a few miles of major highway, air and rail transportation. Our 132,000 sq. ft. manufacturing space is ISO 9001 certified and houses extensive fabrication...

Abrir o catálogo na página 3
Basco Engineered Shell & Tube Heat Exchangers - 4

tascabile 2010 home 146x190.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:9.00pt "Arial", sans-serif; } .font1 { font:12.00pt "Arial", sans-serif; } .font2 { font:18.00pt "Arial", sans-serif; } .font3 { font:9.00pt "Times New Roman", serif; } Engineering Capabilities In-House Resources Degreed staff engineers Օ Applications expertise Mechanical design know-how Օ Product development capabilities Code Capabilities ASME Section VIII Օ PED TUV Օ Chinese CML ASME Section I Օ TEMA C, B & R Canadian Registration Օ Australian AS-1210 Polish UDT Օ Korean...

Abrir o catálogo na página 4
Basco Engineered Shell & Tube Heat Exchangers - 5

tascabile 2010 home 146x190.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:8.00pt "Arial", sans-serif; } .font1 { font:9.00pt "Arial", sans-serif; } .font2 { font:12.00pt "Arial", sans-serif; } .font3 { font:18.00pt "Arial", sans-serif; } Manufacturing Capabilities Manufacturing Skills Torque control rolling Օ Seal and strength welding Polishing, Sanitary 3A Օ TIG, MIG, GMAW, GTAW, SAW and SMAW welding techniques TEMA tight drilling tolerances Quality Assurance Օ X-ray Magnetic particle Օ Heat treatment ISO 9001 Օ Resident ASME code inspector Helium...

Abrir o catálogo na página 5
Basco Engineered Shell & Tube Heat Exchangers - 6

tascabile 2010 home 146x190.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:9.00pt "Arial", sans-serif; } .font1 { font:12.00pt "Arial", sans-serif; } .font2 { font:18.00pt "Arial", sans-serif; } .font3 { font:23.00pt "Arial", sans-serif; } Basco People & Solutions API Basco Shop Bundle Assembly Area API Basco Shop Type OP Assembly Area Team Basa Evaporator with Disengagement Drum Gland Condenser Package Stacked TEMA AEW's with Transfer Values TEMA BEU Exchanger for Wastewater Treatment TYPE ES Intercoolers on a Compressor Package High Pressure TEMA...

Abrir o catálogo na página 6
Basco Engineered Shell & Tube Heat Exchangers - 7

tascabile 2010 home 146x190.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:9.00pt "Arial", sans-serif; } .font1 { font:18.00pt "Arial", sans-serif; } TEMA Shell & Tube Nomenclature API Basco is a proud member of TEMA - Tubular Exchanger Manufacturer's Association. TEMA members set the standards by which virtually all custom shell & tube heat exchangers are specified and built. Basco has been a member since the 1950's, and consequently we have a complete and comprehensive understanding of the engineering, manufacturing and testing requirements to meet this...

Abrir o catálogo na página 7
Basco Engineered Shell & Tube Heat Exchangers - 8

tascabile 2010 home 146x190.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:8.00pt "Arial", sans-serif; } .font2 { font:18.00pt "Arial", sans-serif; } .font3 { font:19.00pt "Franklin Gothic Medium", sans-serif; } TEMA Shell & Tube Spcifications TEMA BET Description: Pull through tube bundle □ studded internai floating head to tubesheet joint □ multi-pass tubeside or single pass with Slip Tube design □ channel or bonnet tubeside connection □ pressure range - 75 psi to 300 psi. Applications: Liquid heaters with low...

Abrir o catálogo na página 8
Basco Engineered Shell & Tube Heat Exchangers - 9

tascabile 2010 home 146x190.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:8.00pt "Arial", sans-serif; } .font2 { font:15.00pt "Arial", sans-serif; } .font3 { font:18.00pt "Arial", sans-serif; } .font4 { font:19.00pt "Franklin Gothic Medium", sans-serif; } TEMA Shell & Tube Spcifications TEMA BEP Description: Removable tube bundle, outside packed floating tubesheet design. Tubesheet assembly may be of fabricated or forged steel to satisfy design pressure requirements □ tubeside fluid is fully gasketed; shellside...

Abrir o catálogo na página 9
Basco Engineered Shell & Tube Heat Exchangers - 10

tascabile 2010 home 146x190.pdf table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:8.00pt "Arial", sans-serif; } .font2 { font:18.00pt "Arial", sans-serif; } .font3 { font:17.00pt "Arial Black", sans-serif; } TEMA Shell & Tube Spcifications TEMA BEU Description: U-tube design with pull through, removable or non-removable tube bundle □ furnished in multi-pass design only □ pressure range - 75 psi to 3000 psi tubeside and 75 psi to 1500 psi shellside. Applications: Chemical processes □ tank suction heater □ liquid heaters...

Abrir o catálogo na página 10

Todos os catálogos e folhetos técnicos API Schmidt-Bretten

  1. OCA Series

    6 Páginas

  2. SIGMASTAR

    2 Páginas

  3. Basco® Type 500

    1 Páginas

  4. BOL Series

    8 Páginas

  5. PCR With FinSep®

    1 Páginas

  6. AOC Series

    4 Páginas

  7. AOL Series

    4 Páginas

  8. BOL Series

    6 Páginas

  9. Evaporators

    8 Páginas

  10. SIGMASHELL

    1 Páginas

  11. Basco Type OP

    8 Páginas

  12. Basco U-Tube

    8 Páginas

  13. Basco Type 500

    12 Páginas

Catálogos arquivados

  1. EKT Series

    2 Páginas

  2. BPCH Series

    2 Páginas

  3. BPS Series

    4 Páginas

  4. BP Series

    20 Páginas

  5. EK Series

    8 Páginas

  6. EC Series

    6 Páginas

  7. CA Series

    4 Páginas

  8. UC Series

    5 Páginas

  9. DH Series

    4 Páginas

  10. MA Series

    4 Páginas

  11. OCA Series

    28 Páginas

  12. AOC DC Fan Drive

    4 Páginas