CALYS 150 - 1

CALYS 150 advanced field documenting calibrator thermometer CALYS 150, the top instrument of the range, works not only as a simulator (IN / OUT) but also as a dual channel thermometer (IN / IN). It calibrates HART transmitters (HART communicator integrated) and thermistors.

Abrir o catálogo na página 1
CALYS 150 - 2

Description CALYS 150 field documenting multifunction calibrator is the top instrument of the range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab measurements, it can simultaneously measure and generate over two isolated channels various signals of temperature, resistance, process, pressure and frequency in one single instrument. CALYS 150 does not only work as a simulator (IN / OUT) but also as a dual channel thermometer (IN / IN) to perform comparison calibration. It calibrates HART transmitters (HART...

Abrir o catálogo na página 2
CALYS 150 - 3

CALYS series, 4 models from basic use to advanced performances Specifications Temperature accuracy DC current + Loop supply 24 V Range Accuracy Range Accuracy Range Accuracy Range Accuracy Range Accuracy Relative pressure: 30 bar / Absolute pressure: 1,000 bar 0.05% RDG 21 CFR Part 11 NADCAP Heat treatment AMS 2750 Additional functions Additional functions Advanced data exploitation: Scaling, relative measurement, simulation of ramps and steps, synthetizer, square root, statistical functions Transmitter function Switch test Calibration of transmitters Additional functions Comparison...

Abrir o catálogo na página 3
CALYS 150 - 4

Specifications Specifications and performances in temperature @23°C ±5°C Uncertainty is given in % of reading (CALYS 150 display) + fixed value. Resistive probes: Measurement and simulation Sensor Range (Input and Output) Accuracy / 1 year (Measurement) Accuracy / 1 year (Simulation) Resistive probes measurements in 2, 3 or 4 wires: automatic recognition of number of connected wires, with indication on screen Accuracies are given for 4-wire mounted probes Take into account particular error of temperature sensor used and implementation conditions Admissible measuring current: 0.01 mA to 1 mA...

Abrir o catálogo na página 4
CALYS 150 - 5

Frequency, counting: Measurement Range Scale unit: Pulse / min and Hz Trigger level: 1 V Measurement on frequency signals or dry contacts. Counting will be performed on defined time or infinite time. Resistance: Measurement Range Measurement range Resistance measurement in 2, 3 or 4 wires: automatic recognition of number of connected wires, with indication on screen Accuracies are given for 4-wire mounted probes DC current: Emission With or without loop supply Range DC voltage: Emission Range Emission range

Abrir o catálogo na página 5
CALYS 150 - 6

Frequency, pulse: Emission Range Scale unit: Pulse / min and Hz Pulse emission and dry contacts simulation. Max. amplitude: 20 V (User selectable) Resistance: Emission Range Emission range Nota Iext Emission with pulsed current available: refer to the instruction manual for specifications Temperature coefficient: Current establishing time:

Abrir o catálogo na página 6
CALYS 150 - 7

Models and accessories Instrument: CALYS 150 On-site documenting multifunction calibrator Delivered in standard with: User manual Battery charger Set of 6 testing leads Carrying strap Factory test report External digital pressure sensor for CALYS 75 / 100 / 150 (Absolute or relative pressure) Different ranges available from 0 to 1,000 bar Range from -1 -> 1; 3; 10; 30 (absolute or relative pressure) Range from -1 -> 100; 300; 1,000 (absolute pressure only) Standard accuracy: 0.05% FS Transport case for CALYS series Set of 6 measuring cables with removable crocodile clips Hart modem for...

Abrir o catálogo na página 7
CALYS 150 - 8

Packing information: Size Weight without packing 900 g

Abrir o catálogo na página 8

Todos os catálogos e folhetos técnicos AOIP

  1. DRAGO 934

    5 Páginas

  2. CALYS 1200

    10 Páginas

  3. CALYS 1000

    10 Páginas

  4. RAYOMATIC 16

    7 Páginas

  5. RLV

    5 Páginas

  6. EPM

    10 Páginas

  7. UNIGAS 3000

    7 Páginas

  8. RN 5306

    5 Páginas

  9. TTI 10

    6 Páginas

  10. RN 5360

    5 Páginas

  11. MEGOHM 200

    7 Páginas

  12. MF 28

    6 Páginas

  13. IND 45

    6 Páginas

  14. CALYS 1500

    12 Páginas

  15. RAYOMATIC USB 2.2

    6 Páginas

  16. RAYOMATIC PE

    6 Páginas

  17. IRTEC P IVT

    5 Páginas

  18. RAYOMATIC 16 2.2

    6 Páginas

  19. RAYOMATIC NET

    6 Páginas

  20. RAYOMATIC TC

    6 Páginas

  21. ICO 51

    6 Páginas

  22. LKS 1000

    5 Páginas

  23. MILLIK

    7 Páginas

  24. TC 6621 / 6622

    10 Páginas

  25. SN 8310

    7 Páginas

  26. CALYS 60 IS

    9 Páginas

  27. CP 6632

    7 Páginas

  28. THERMYS 150

    10 Páginas

  29. CALYS 120 IS

    12 Páginas

  30. ZX

    5 Páginas

  31. OM 10

    6 Páginas

  32. OM 21

    8 Páginas

  33. ISOPALM 200

    7 Páginas

  34. CRIT 100

    4 Páginas

  35. IRtec P

    11 Páginas

  36. FD 5 / 10 / 15

    12 Páginas

  37. VNE20

    5 Páginas

  38. OM 16

    8 Páginas

  39. SATURN CYCLOP 878

    4 Páginas

  40. CALYS 80 IS

    11 Páginas

  41. CALYS 80P

    10 Páginas

  42. P200 PRO

    8 Páginas

  43. motor starter

    4 Páginas

Catálogos arquivados