Grupo: Angst+Pfister
Excertos do catálogo

Features □ Supply voltage: 1.7 to 5.5V(Vdd) 1.2 to 5.5V(Vddio) □ 1.4MPa pressure range □ 2.2ms fastest conversion time □ Calibrated and temperature compensated Application Examples □ Sport watch □ Diving watch □ Smart watch Descriptions The PBM220 is a new generation of high resolution digital barometer. The PBM220 is a digital pressure sensor which consists of a MEMS piezoresistive pressure sensor and a signal conditioning ASIC. The ASIC include a 24bits sigma-delta ADC, OTP memory for calibration data, and serial interface circuits. The PBM220 could provide both I2C and SPI interface to communicate with microcontroller. Pressure calibrated and temperature compensated were key features of the PBM220. The data stored in OTP memory could be used to calibrate the PBM220. The calibration procedure should be implemented by a external microprocessor. The PBM220 is low power and supply voltage designed and suitable for portable devices or battery-supplied ones. The PBM220 is designed for water resistant applications. Ordering information Competitive sensor & power supply solutions worldwide
Abrir o catálogo na página 1
Competitive sensor & power supply solutions worldwide
Abrir o catálogo na página 2
1 Functional Block and Pin Descriptions Competitive sensor & power supply solutions worldwide
Abrir o catálogo na página 3
Competitive sensor & power supply solutions worldwide
Abrir o catálogo na página 4
4 Application Information Owing to state of the art, the PBM220 build a new standard of digital barometer. A 24bits sigma-delta ADC and a MEMS pressure sensor are integrated in a LGA substrate. Pressure calibrated and temperature compensated were key features of the PBM220. The PBM220 is low power and supply voltage designed and suitable for portable devices or battery-supplied ones. The data stored in OTP memory could be used to calibrate the PBM220. The calibration procedure should be implemented by a external microprocessor. By I2C or SPI interface, you can get the calibration data...
Abrir o catálogo na página 5
5 Control registers Table 5.1 control registers Reg 0xF6-0xF8 Data_out: 24 bits ADC output data Reg 0xF4 OSR<1:0>: 00:1024X, 01:2048X, 10:4096X, 11:8192X Measurement_control<5:0>: 101110, indicate a temperature conversion. 110100, indicate a pressure conversion. Reg 0xE0 Softreset : Write only register. If set to 0xB6, will perform a power on reset sequence. Auto returned to 0 after the soft reset completed. Reg {0xF1, 0xD0, 0xBB:0xAA} Calibration Registers : Total 20bytes calibration registers used for sensor calibration. Reg 0x6B PartID: 8 bits Part ID, the default value is 0x42. Reg...
Abrir o catálogo na página 6
Table 5.2 Summary of instructions Competitive sensor & power supply solutions worldwide
Abrir o catálogo na página 7
Figure 6.1 SPI timing diagram The falling edge of CSB, in conjunction with the rising edge of SCLK, determines the start of framing. Once the beginning of the frame has been determined, timing is straightforward. The first phase of the transfer is the instruction phase, which consists of 16 bits followed by data that can be of variable lengths in multiples of 8 bits. If the device is configured with CSB tied low, framing begins with the first rising edge of SCLK. The instruction phase is the first 16 bits transmitted. As shown in Figure 5.2, the instruction phase is divided into a number of...
Abrir o catálogo na página 8
Data follows the instruction phase. The amount of data sent is determined by the word length (Bit W0 and Bit W1). This can be one or more bytes of data. All data is composed of 8-bit words. Data can be sent in either MSB-first mode or LSB-first mode (by setting ‘LSB_first’ bit). On power up, MSB-first mode is the default. This can be changed by programming the configuration register. In MSB-first mode, the serial exchange starts with the highest-order bit and ends with the LSB. In LSB-first mode, the order is reversed. (Figure 6.3) CSB \I SDIO DON'T CARE \ R/W W1 | W0 | A12 | A11 |...
Abrir o catálogo na página 9
Table 7.2 Electrical specification of the I2C interface pins The I2C interface protocol has special bus signal conditions. Start (S), stop (P) and binary data conditions are shown below. At start condition, SCL is high and SDA has a falling edge. Then the slave address is sent. After the 7 address bits, the direction control bit R/W selects the read or write operation. When a slave device recognizes that it is being addressed, it should acknowledge by pulling SDA low in the ninth SCL (ACK) cycle. At stop condition, SCL is also high, but SDA has a rising edge. Data must be held stable at SDA...
Abrir o catálogo na página 10
*T\Lr::r\_Ai:: xxjcxn DATA ACK START ADDRESS R/W ACK condition DATA ACK STOP Competitive sensor & power supply solutions worldwide
Abrir o catálogo na página 11
8.3.2 Sensor orientation relative to the tape Competitive sensor & power supply solutions worldwide
Abrir o catálogo na página 12
Competitive sensor & power supply solutions worldwide
Abrir o catálogo na página 13
Office Germany: Pewatron AG Neumarkter StraEe 86a D-81673 Munich Phone +49 89 260 38 47 infode@pewatron.com PEWATRON SENSORS ■ POWER SUPPLIES We are here for you. Addresses and Contacts. Postcode 1000 - 2999 Eric Letsch Pewatron AG Thurgauerstrasse 66 CH-8052 Zurich Phone + 41 44 877 35 14 Mobile + 41 76 491 66 70 eric.letsch@pewatron.com Sales International Key Accounts Sales Austria Sales Other Countries / Product Pressure Sensors Gas sensors / Gas sensor modules Load cells Thomas Clausen Phone + 41 44 877 35 13 thomas.clausen@pewatron.com Linear position sensors Angle sensors Eric...
Abrir o catálogo na página 14Todos os catálogos e folhetos técnicos Angst+Pfister Sensors and Power AG
-
PAROX 1200 Paramagnetic O2 sensor
4 Páginas
-
SQ-UST_L_0105-01
4 Páginas
-
SQ-UST_L_0104-01
4 Páginas
-
SQ-UST_L_0103-01
4 Páginas
-
SQ-UST_L_0003-01
3 Páginas
-
SQ-UST_L_0002-01
3 Páginas
-
SQ-UST_L_0001-01
3 Páginas
-
PFLOW Series
5 Páginas
-
Model PFLOW3000 Series
16 Páginas
-
LoadSensor StarterKit
3 Páginas
-
Model PFLOW2001 Series
14 Páginas
-
PHPSU 4502 Pressure Transducer
6 Páginas
-
Pewatron PHPSU-4502 vs SCX Series
4 Páginas
-
PSB82_1685-21629-0010-E-1118
3 Páginas
-
V3D-150_1610-21914-0010-E-0620
2 Páginas
-
V3D-070_1610-21914-0009-E-0620
2 Páginas
-
PHPS5600 Pressure Transducer
6 Páginas
-
PHPS-5500_1610-21914-0013-E-0920
7 Páginas
-
PEWA200 Pressure Transmitter
7 Páginas
-
Pewatron PHPSU-4501 vs SCX Series
4 Páginas
-
PHPSU4501 Pressure Transducer
6 Páginas
-
FCX-MC25 & FCX-MC95 OEM module
4 Páginas
-
PZA-MC25-N/P
2 Páginas
-
OXYPA paramagnetic oxygen sensor
4 Páginas
-
PEWA100
9 Páginas
-
HLP-80H series
5 Páginas
-
HLP-40H series
5 Páginas
-
HBG-60P series
6 Páginas
-
UHP-750 series
6 Páginas
-
XLG-50 seri es
9 Páginas
-
DAP-04 series
8 Páginas
-
POB-30 series
11 Páginas
-
RHP-1U Rack System
9 Páginas
-
RFP-M8M4-5A
5 Páginas
-
RFP-M5M3-3A
4 Páginas
-
RFP-M2M3-3A
4 Páginas
-
RFP-M1M3-3A
4 Páginas
-
NCL CL1 01
4 Páginas
-
IRL RGB 01
4 Páginas
-
IRL CL2 01
4 Páginas
-
MSR385WD
3 Páginas
-
MSR145WD
3 Páginas
-
MSR 145
3 Páginas
-
M2029
3 Páginas
-
MSR165
3 Páginas
-
APBL42 Series Brushless DC Motor
2 Páginas
-
CRM102.1
33 Páginas
-
CRM200
39 Páginas
-
CRM100
37 Páginas
-
FPM
4 Páginas
-
FGN
4 Páginas
-
FPN
4 Páginas
-
Pressure Transducer PHPS-3500
6 Páginas
-
PBM220-A14N series
14 Páginas
-
PBM220 series
15 Páginas
-
PBM210-A20K Series
14 Páginas
-
STX Series – Model 13A
11 Páginas
-
CCD Series – Model 53A
7 Páginas
-
CCD Series – Model 54D
20 Páginas
-
APB2Series
5 Páginas
-
AP4Series
5 Páginas
-
AP2Series
5 Páginas
-
PHPS-7500 OEM
6 Páginas
-
PPCP3-M1
10 Páginas
-
AG4Series
6 Páginas
-
AG2Series
5 Páginas
-
New Pewatron brochure
11 Páginas
-
GST220A
4 Páginas
-
GSM40B
6 Páginas
-
GSM36B
4 Páginas
-
GSC25E
5 Páginas
-
TDR-480
5 Páginas
-
GC120
4 Páginas
-
HDR-30
5 Páginas
-
GSM220A
6 Páginas
-
EPP-400
5 Páginas
-
ENP-120
5 Páginas
-
ENC-120
6 Páginas
-
ATX-100
4 Páginas
-
RPS-200
7 Páginas
-
APBR30X75
2 Páginas
-
APBR30X60
2 Páginas
-
APBR 30X50 MM
2 Páginas
-
PSB54/16
2 Páginas
-
PSB54/14
2 Páginas
-
PSB36T/16
2 Páginas
-
PSB35T/12
2 Páginas
-
PSB25T/16
2 Páginas
-
PSB25T/12
2 Páginas
-
PSB21/12
2 Páginas
-
PSB 21
2 Páginas
-
AD-Series
16 Páginas
-
DMU11
3 Páginas
-
HDR-30 series
5 Páginas
-
DMU30-01
25 Páginas
-
DMU30
3 Páginas
-
HPSD 4000 Pressure Transducer 1/7
8 Páginas
-
DKA30 serie s
2 Páginas
-
DCW12
2 Páginas
-
DCW05
2 Páginas
-
EH - EF 80 C/P/K
3 Páginas
-
7S Series
3 Páginas
-
Model CE36M
3 Páginas
-
EX 80 A
3 Páginas
-
STX13A_100-31-410-002-EH-0417
3 Páginas
-
STX13A-D_100-31-410-005-EH-0817
11 Páginas
-
PBM220_100-33-421-003-EH-1216
16 Páginas
-
PBM220-07N_100-33-421-007-EH-0617
14 Páginas
-
ABS5_100-33-102-001-EH-1016
2 Páginas
-
PHPS-8500_100-31-331-003-EH-0617
12 Páginas
-
FJK-OV_100-31-102-009-EH-1116
2 Páginas
-
100 33 102 012 EH 0315
6 Páginas
-
100 33 102 007 EH 0315
5 Páginas
-
UFO
3 Páginas
-
UFO-M2
3 Páginas
-
ELTRA ABSOLUTE ENCODER OVERVIEW
3 Páginas
-
Dummy DC-Motoren
2 Páginas
-
FCX-MP1000-Extern-FH-CH
3 Páginas
-
GC30E
3 Páginas
-
RPS-400
11 Páginas
-
GC 330
4 Páginas
-
EL30
3 Páginas
-
EA PROFIBUS
7 Páginas
-
EAMW
3 Páginas
-
AAM58
4 Páginas
-
EAM36
3 Páginas
-
ELTRA INCREMENTAL ENCODER OVERVIEW
3 Páginas
-
CARBONOXY25
2 Páginas
-
CARBONDIO-%
2 Páginas
-
FCX-ML25-EXTERN-CH
14 Páginas
-
FCX-MC25-CH
3 Páginas
-
FCX-MC05-CH
3 Páginas
-
FCX-TR0025
4 Páginas
-
A-SeriesOV_100-31-102-011-EH-0317
3 Páginas
-
LP-10HA
3 Páginas
-
FCX-UC-CH
9 Páginas
-
901.1-EX
5 Páginas
-
FC22
3 Páginas
-
MILLINEWTON
3 Páginas
-
PFLOW10U-2210
5 Páginas
-
901.1
5 Páginas
-
HX-EP
6 Páginas
-
VQ548MP & MP-7217
5 Páginas
-
Air quality sensing
6 Páginas
-
Tailor-made
10 Páginas
-
RAZTEC
13 Páginas
-
The SGX-SureCO
3 Páginas
-
930 Climair
5 Páginas
-
984 pressure transmitter
5 Páginas
-
PEM pressure transmitter
5 Páginas
-
Pressure sensor CCD54
4 Páginas
-
MSP-600 600W AC/DC
5 Páginas
-
FCX-MP1000-Extern-FH-CH
3 Páginas
-
Pewatron_Flyer_EN
8 Páginas