MEMS Mass Flow Sensor Description The PFLOW2001 series of mass flow sensors are made with micromachined (MEMS) sensing elements that offer an innovative thermal sensing principle with excellent linearity and removal of gas sensitivity of some common gases. This PFLOW2001 Series mass flow sensor series offer a fully customizable flow dynamic range of 100:1 with the full-scale flowrate from 30 sccm to 5000 sccm. The sensors are opted with digital and analog interface, bi-directional sensing capability with an operational temperature range of -25 to 85 °C (-13 to 185 °F). Wide supply voltage 8...
Abrir o catálogo na página 2
Revision History Rev. Change No. 1.0 Initial revision 1.1 Update of the I2C communication PFLOW2001 I2C Application Note Step model of the sensor
Abrir o catálogo na página 3
SPECIFICATIONS Absolute maximum ratings (1) Item Supply voltage, VDDmax I2C bus voltage, VDDIOmax Low voltage version Normal and low voltage version I2C frequency, fI2Cmax Maximum common mode pressure, Pmax Maximum overflow, Qmax of full scale flowrate Maximum flowrate change of full scale flowrate Operating temperature range, Top Storage temperature, Tstg Mechanical shock Notes: 1. Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. 2. sccm denotes standard cubic centimeters per minute. Standard conditions: 20°C, 101.325kPa, dry and clean air Performance...
Abrir o catálogo na página 4
Electrical Characteristics (Test conditions: VDD = 8-15VDC, Ta = 20°C, RHa = 30…70%, unless otherwise stated) Item Supply current Minimum output load Analog output (rated), Vout (3) 1 Low voltage version Low voltage version Analog null voltage - bidirectional Analog null voltage unidirectional Digital and analog output analog & digital output I2C Normal and low voltage version Analog null drift Analog maximum output (5) Digital maximum output I2C bus voltage (6) Resolution digital output Digital null offset (8) Digital null drift Notes: 1. Warm-up time is the time from power on to the first...
Abrir o catálogo na página 5
Pressure drop characteristics Part no. Flow Range Pressure drop MECHANICAL DIMENSIONS Flow direction Flow direction from left to right for uni-directional sensors. Please refer t
Abrir o catálogo na página 6
ELECTRICAL INTERFACE Digital and analog version pinout Pin# Analog voltage output I2C clock Figure 2 Digital and analog version (VI2C) pin assignment Analog only version pinout The only analog 3-pin version is as a replacement for retrofit and older designs, where only analog output is required. Pin# Analog voltage output GND Figure 3 Analog only 3-pin version GAS CORRECTION FACTORS Gas type Air Oxygen (O2) Nitrogen (N2) Argon (Ar) Hydrogen (H2) Carbon dioxide (CO2) *For Hydrogen applications please contact the manufacturer. The custom factory calibration with H2 needs to be performed, to...
Abrir o catálogo na página 7
TYPICAL ANALOG OUTPUT
Abrir o catálogo na página 8
TYPICAL DIGITAL OUTPUT
Abrir o catálogo na página 9
Figure 7. Analog and I2C interface connection diagram When not using the analog output, the pin 1 shall be left unconnected (floating). Shortening Pin 1 to GND will cause malfunction of the sensor. When not using the digital I2C output, the pin 4 and pin 5 shall be left unconnected (floating). Shortening Pin 4 and/ or 5 to GND will cause malfunction of the sensor. Only for low power version of the sensor the VDD and VDDIO can be connected together.
Abrir o catálogo na página 10
DIGITAL I2C COMMUNICATION I2C interface command description The default I2C address of the sensor is 0x50. Command Name Read/ Write Width (Byte) Notes Write the new address in 8-bit format It will be transformed to 7-bit (shifted right) i.e.: 0x0A (8-bit) -> 0x05 (7-bit) Send new address in 2 Bytes + CRC i.e.: new I2C address is 0x05 (7-bit), then send 3 Bytes: 0x00, 0x0A, 0x36 Please refer to Application note for details and code sample Flowrate offset reset Serial number Flow rate Write to the sensor 2-bytes of any fixed value (will be ignored). Ensure no-flow conditions HEX, ASCII code...
Abrir o catálogo na página 11
5. All the data from the sensor are transmitted in following sequence: 2-Bytes Data, 1 Byte CRC, 2Bytes data, 1-Byte CRC. i.e: Serial number: 2A 2A FA 42 31 E6 52 33 BF 31 33 75 34 33 34 2A 2A FA without CRC: 2A 2A 42 31 52 33 31 33 34 33 2A 2A in ASCII: **B1R31343** 6. All data written to the sensor shall be in 2-Byte format followed by 1 Byte CRC. i.e.: reset flow rate offset: Send to the sensor the command to reset offset: 0x00, 0xF0 Write to the sensor any 2-Byte fixed value i.e. 0xAA, 0x55 Follow it by CRC-8: 0x36 7. Refer to the PFLOW 2001 I2C Application Note for details [1] I2C...
Abrir o catálogo na página 12
CRC checksum calculation The 8-bit CRC checksum transmitted after each two data bytes (int 16) is generated by a CRC algorithm. Its properties are listed in the following table. To calculate the checksum, only these two previously transmitted data bytes are used. Property Protected data Reflect input Reflect output ORDERING INFORMATION The product part number is composed of the product model number and suffix indicating the full-scale flow rate, mechanical connection, output format as well as the applicable gas. Refer to the following for the product order: PFLOW2001 Gas (A: air, N2, O2,...
Abrir o catálogo na página 13
We are here for you. Addresses and Contacts. Headquarter Switzerland: Office Germany: Angst+Pfister Sensors and Power AG Angst+Pfister Sensors and Power Deutschland GmbH Scan here and get an overview of personal contacts! for sensors and power solutions
Abrir o catálogo na página 14Todos os catálogos e folhetos técnicos Angst+Pfister Sensors and Power AG
-
PAROX 1200 Paramagnetic O2 sensor
4 Páginas
-
SQ-UST_L_0105-01
4 Páginas
-
SQ-UST_L_0104-01
4 Páginas
-
SQ-UST_L_0103-01
4 Páginas
-
SQ-UST_L_0003-01
3 Páginas
-
SQ-UST_L_0002-01
3 Páginas
-
SQ-UST_L_0001-01
3 Páginas
-
PFLOW Series
5 Páginas
-
Model PFLOW3000 Series
16 Páginas
-
LoadSensor StarterKit
3 Páginas
-
PHPSU 4502 Pressure Transducer
6 Páginas
-
Pewatron PHPSU-4502 vs SCX Series
4 Páginas
-
PSB82_1685-21629-0010-E-1118
3 Páginas
-
V3D-150_1610-21914-0010-E-0620
2 Páginas
-
V3D-070_1610-21914-0009-E-0620
2 Páginas
-
PHPS5600 Pressure Transducer
6 Páginas
-
PHPS-5500_1610-21914-0013-E-0920
7 Páginas
-
PEWA200 Pressure Transmitter
7 Páginas
-
Pewatron PHPSU-4501 vs SCX Series
4 Páginas
-
PHPSU4501 Pressure Transducer
6 Páginas
-
FCX-MC25 & FCX-MC95 OEM module
4 Páginas
-
PZA-MC25-N/P
2 Páginas
-
OXYPA paramagnetic oxygen sensor
4 Páginas
-
PEWA100
9 Páginas
-
HLP-80H series
5 Páginas
-
HLP-40H series
5 Páginas
-
HBG-60P series
6 Páginas
-
UHP-750 series
6 Páginas
-
XLG-50 seri es
9 Páginas
-
DAP-04 series
8 Páginas
-
POB-30 series
11 Páginas
-
RHP-1U Rack System
9 Páginas
-
RFP-M8M4-5A
5 Páginas
-
RFP-M5M3-3A
4 Páginas
-
RFP-M2M3-3A
4 Páginas
-
RFP-M1M3-3A
4 Páginas
-
NCL CL1 01
4 Páginas
-
IRL RGB 01
4 Páginas
-
IRL CL2 01
4 Páginas
-
MSR385WD
3 Páginas
-
MSR145WD
3 Páginas
-
MSR 145
3 Páginas
-
M2029
3 Páginas
-
MSR165
3 Páginas
-
APBL42 Series Brushless DC Motor
2 Páginas
-
CRM102.1
33 Páginas
-
CRM200
39 Páginas
-
CRM100
37 Páginas
-
FPM
4 Páginas
-
FGN
4 Páginas
-
FPN
4 Páginas
-
Pressure Transducer PHPS-3500
6 Páginas
-
PBM220-A14N series
14 Páginas
-
PBM220 series
15 Páginas
-
PBM210-A20K Series
14 Páginas
-
STX Series – Model 13A
11 Páginas
-
CCD Series – Model 53A
7 Páginas
-
CCD Series – Model 54D
20 Páginas
-
APB2Series
5 Páginas
-
AP4Series
5 Páginas
-
AP2Series
5 Páginas
-
PHPS-7500 OEM
6 Páginas
-
PPCP3-M1
10 Páginas
-
AG4Series
6 Páginas
-
AG2Series
5 Páginas
-
New Pewatron brochure
11 Páginas
-
GST220A
4 Páginas
-
GSM40B
6 Páginas
-
GSM36B
4 Páginas
-
GSC25E
5 Páginas
-
TDR-480
5 Páginas
-
GC120
4 Páginas
-
HDR-30
5 Páginas
-
GSM220A
6 Páginas
-
EPP-400
5 Páginas
-
ENP-120
5 Páginas
-
ENC-120
6 Páginas
-
ATX-100
4 Páginas
-
RPS-200
7 Páginas
-
APBR30X75
2 Páginas
-
APBR30X60
2 Páginas
-
APBR 30X50 MM
2 Páginas
-
PSB54/16
2 Páginas
-
PSB54/14
2 Páginas
-
PSB36T/16
2 Páginas
-
PSB35T/12
2 Páginas
-
PSB25T/16
2 Páginas
-
PSB25T/12
2 Páginas
-
PSB21/12
2 Páginas
-
PSB 21
2 Páginas
-
AD-Series
16 Páginas
-
DMU11
3 Páginas
-
HDR-30 series
5 Páginas
-
DMU30-01
25 Páginas
-
DMU30
3 Páginas
-
HPSD 4000 Pressure Transducer 1/7
8 Páginas
-
DKA30 serie s
2 Páginas
-
DCW12
2 Páginas
-
DCW05
2 Páginas
-
EH - EF 80 C/P/K
3 Páginas
-
7S Series
3 Páginas
-
Model CE36M
3 Páginas
-
EX 80 A
3 Páginas
-
STX13A_100-31-410-002-EH-0417
3 Páginas
-
STX13A-D_100-31-410-005-EH-0817
11 Páginas
-
PBM220_100-33-421-003-EH-1216
16 Páginas
-
PBM220-14N_100-33-421-008-EH-0617
14 Páginas
-
PBM220-07N_100-33-421-007-EH-0617
14 Páginas
-
ABS5_100-33-102-001-EH-1016
2 Páginas
-
PHPS-8500_100-31-331-003-EH-0617
12 Páginas
-
FJK-OV_100-31-102-009-EH-1116
2 Páginas
-
100 33 102 012 EH 0315
6 Páginas
-
100 33 102 007 EH 0315
5 Páginas
-
UFO
3 Páginas
-
UFO-M2
3 Páginas
-
ELTRA ABSOLUTE ENCODER OVERVIEW
3 Páginas
-
Dummy DC-Motoren
2 Páginas
-
FCX-MP1000-Extern-FH-CH
3 Páginas
-
GC30E
3 Páginas
-
RPS-400
11 Páginas
-
GC 330
4 Páginas
-
EL30
3 Páginas
-
EA PROFIBUS
7 Páginas
-
EAMW
3 Páginas
-
AAM58
4 Páginas
-
EAM36
3 Páginas
-
ELTRA INCREMENTAL ENCODER OVERVIEW
3 Páginas
-
CARBONOXY25
2 Páginas
-
CARBONDIO-%
2 Páginas
-
FCX-ML25-EXTERN-CH
14 Páginas
-
FCX-MC25-CH
3 Páginas
-
FCX-MC05-CH
3 Páginas
-
FCX-TR0025
4 Páginas
-
A-SeriesOV_100-31-102-011-EH-0317
3 Páginas
-
LP-10HA
3 Páginas
-
FCX-UC-CH
9 Páginas
-
901.1-EX
5 Páginas
-
FC22
3 Páginas
-
MILLINEWTON
3 Páginas
-
PFLOW10U-2210
5 Páginas
-
901.1
5 Páginas
-
HX-EP
6 Páginas
-
VQ548MP & MP-7217
5 Páginas
-
Air quality sensing
6 Páginas
-
Tailor-made
10 Páginas
-
RAZTEC
13 Páginas
-
The SGX-SureCO
3 Páginas
-
930 Climair
5 Páginas
-
984 pressure transmitter
5 Páginas
-
PEM pressure transmitter
5 Páginas
-
Pressure sensor CCD54
4 Páginas
-
MSP-600 600W AC/DC
5 Páginas
-
FCX-MP1000-Extern-FH-CH
3 Páginas
-
Pewatron_Flyer_EN
8 Páginas