FCX-ML25-EXTERN-CH
1 / 14Páginas

Excertos do catálogo

FCX-ML25-EXTERN-CH - 1

Operating manualOxygen sensor module FCX-MLxx-CH & FCX-MLxx-Extern -CH Competitive sensor & power supply solutions worldwide

Abrir o catálogo na página 1
FCX-ML25-EXTERN-CH - 2

This manual contain information on how to operate the standard Pewatron OEM FCX-MLxx-CH and FCX-MLxx-Extern-CH products. The standard FCX-MLxx-CH configuration always have the oxygen sensor soldered onto the PCB and covered with an aluminium flow housing. The standard FCX-MLxx-Extern-CH configuration have the oxygen sensor connected to the PCB via a 30 cm long cable. The oxygen sensor can be chosen from a selection of 3 sensors; 3) the FCX-UWC 0.1.95% (xx = 95) As an example the FCX-ML95-CH Module is a 0.1-95% FCX-UWC oxygen sensor module used in flow applications or in applications where a...

Abrir o catálogo na página 2
FCX-ML25-EXTERN-CH - 3

1 List of Contents Page 1. Safety instructions

Abrir o catálogo na página 3
FCX-ML25-EXTERN-CH - 4

2 Customer Service At PEWATRON AG, we want to offer you the best customer service possible. If you have any questions or comments about your FCX-MLxx-CH or FCX-MLxx-Extern-CH modules, we would be happy to hear from you. Should you have any problems with the modules, please contact us for advice and support. We recommend that all service and repair work on the unit be done exclusively by our customer service or specially trained personnel. You can reach us at the following addresses: Headquarter: PEWATRON AG Thurgauerstrasse 66 8052 Zurich Switzerland Tel +41 (0)44-877 35 00 Fax +41...

Abrir o catálogo na página 4
FCX-ML25-EXTERN-CH - 5

3 Safety instructions Danger sources that could result in personal injury or damage to machinery are explicitly indicated in the appropriate places in the user documentation. Before installing the machine, please read this operating manual carefully. Pay particular attention to the sections explaining possible hazards. Warnings and instructions are shown as follows: A Means that failure to follow the instruction indicated can lead to personal injury. Means that the instruction indicated must be followed exactly to prevent damage to the machine. Competitive sensor & power supply solutions...

Abrir o catálogo na página 5
FCX-ML25-EXTERN-CH - 6

4 Measuring Principle The sensor module is a complete solution for fast and accurate oxygen concentration measurements within the range 0...5% (ML05), 0...25% (ML25) or 0.1...95% (ML95). The sensor and the measurement electronics are located on a PCB (FCX-MLxx-CH). Alternatively, the oxygen sensor can be connected to the PCB via a cable (FCX-MLxx-extern-CH). The electronic amplifies the raw sensor signal and the output is a logarithmic current output signal 4.20mA (according to IEC 60381) as a function of oxygen partial pressure (see Appendix) Zirconium oxide, heated to about 450 °C, is...

Abrir o catálogo na página 6
FCX-ML25-EXTERN-CH - 7

5 Commissioning 5.1 Mechanical Installation The PCB has dimensions 75 x 40 x 28 mm (including the flow housing) (Fig.1.). There are two different variants for how the sensor can be connected to the module: Soldered directly onto the PCB or using a plug cable connector. In Fig. 2 below is shown the PCB with a sensor soldered directly onto the PCB and covered with an aluminium flow housing. In Fig.3 below is shown the PCB without a sensor, but with a plug cable connector. Fig. 1 PCB electronic layout for FCX-MLxx-CH/FCX-MLxx-Extern-CH Fig. 2 PCB side with flow housing; FCX-MCxx-CH Fig. 3 PCB...

Abrir o catálogo na página 7
FCX-ML25-EXTERN-CH - 8

In each corner of the PCB, there are mounting holes with a diameter of 3.5 mm. The distance between the centre of mounting holes are 67 and 32 mm, respectively. A The PCB has highly sensitive circuitry. During installation, be careful that none of the caution components are damaged mechanically. 5.2 Pneumatic connections The flow housing has two hose connectors with a diameter of 5 mm. The direction of flow can be chosen arbitrarily. A Hoses containing silicone should not be used. Gases containing silicon destroy the sensor Caution cr GND Stromausgang (4..20 mA) GND Speisung (10..28 VDC) a...

Abrir o catálogo na página 8
FCX-ML25-EXTERN-CH - 9

6 Environment Condition See also under 11. Specifications, in particular for the temperature and humidity ranges (not condensing). • Operation outdoors not permitted. • Protect from moisture The sensor temperature is about 450 °C. Please note in any case the resulting hazards for applications with reactive gas mixtures. Potentially explosive atmospheres The unit may under no circumstances be operated in or with potentially explosive atmospheres. 7 Warm Up Time The module need a warm up time of approx. 3 minutes. After 3 minutes the sensor delivers an output signal which is within the...

Abrir o catálogo na página 9
FCX-ML25-EXTERN-CH - 10

9.1 Calibration Adjustments It is recommended to check the device periodically by running it under regular lab conditions and flush the sensor with regular air (20.95% O2). 9.2 Adjustment Span and Zero Initial calibration of the ML module needed for operation has been carried out at the factory. The result of a measurement in air and at a temperature of 25°C should be 20.95 %O2 +0.2/-0.5% O2. Should there be a higher difference the module output can be adjusted according to the following procedure: 1 Attach the module to the supply 2 Use the sensor in regular air (20.95% O2). For the 0...5%...

Abrir o catálogo na página 10
FCX-ML25-EXTERN-CH - 11

9.3 Adjustment if the sensor need to be replaced 1. Attach the module to the supply 2. After approx. 10 minutes adjust the sensor heating (U Heat) using the potentiometer (Heizspannung) and jumpers S1 and S2 for fine adjusting (see jumper configuration below). Please note that the VH differs from sensor to sensor and has to be adjusted at an accuracy of +0.005V. The corresponding values can be found on the attached calibration sheet. open open close open open dose close close 3. Use the sensor in regular air (20.9% O2). For the 0...5% sensor please use a N2-O2 gas with an oxygen...

Abrir o catálogo na página 11
FCX-ML25-EXTERN-CH - 12

10 Important notes 10.1 Restrictions 1 Do not remove the sensor from the circuit board. 2 Do not change the length of the lead wires. 3 Please use regulated DC power source with current capacity over 1 ampere/pc. If current capacity is not sufficient, the sensor module will not operate correctly. 4 This sensor module was adjusted for O2-N2 system. Output characteristics may change if there are other gases present in the gas mixture to be measured. 5 Don't use in a gas that contains the halogen atoms (F, Cl, Br). The sensor can be damaged by decomposition of a gas containing halogen atoms. 6...

Abrir o catálogo na página 12

Todos os catálogos e folhetos técnicos Angst+Pfister Sensors and Power AG

  1. SQ-UST_L_0105-01

    4 Páginas

  2. SQ-UST_L_0104-01

    4 Páginas

  3. SQ-UST_L_0103-01

    4 Páginas

  4. SQ-UST_L_0003-01

    3 Páginas

  5. SQ-UST_L_0002-01

    3 Páginas

  6. SQ-UST_L_0001-01

    3 Páginas

  7. PFLOW Series

    5 Páginas

  8. PZA-MC25-N/P

    2 Páginas

  9. PEWA100

    9 Páginas

  10. HLP-80H series

    5 Páginas

  11. HLP-40H series

    5 Páginas

  12. HBG-60P series

    6 Páginas

  13. UHP-750 series

    6 Páginas

  14. XLG-50 seri es

    9 Páginas

  15. DAP-04 series

    8 Páginas

  16. POB-30 series

    11 Páginas

  17. RFP-M8M4-5A

    5 Páginas

  18. RFP-M5M3-3A

    4 Páginas

  19. RFP-M2M3-3A

    4 Páginas

  20. RFP-M1M3-3A

    4 Páginas

  21. NCL CL1 01

    4 Páginas

  22. IRL RGB 01

    4 Páginas

  23. IRL CL2 01

    4 Páginas

  24. MSR385WD

    3 Páginas

  25. MSR145WD

    3 Páginas

  26. MSR 145

    3 Páginas

  27. M2029

    3 Páginas

  28. MSR165

    3 Páginas

  29. CRM102.1

    33 Páginas

  30. CRM200

    39 Páginas

  31. CRM100

    37 Páginas

  32. FPM

    4 Páginas

  33. FGN

    4 Páginas

  34. FPN

    4 Páginas

  35. PBM220-A14N series

    14 Páginas

  36. PBM220 series

    15 Páginas

  37. PBM210-A20K Series

    14 Páginas

  38. APB2Series

    5 Páginas

  39. AP4Series

    5 Páginas

  40. AP2Series

    5 Páginas

  41. PHPS-7500 OEM

    6 Páginas

  42. PPCP3-M1

    10 Páginas

  43. AG4Series

    6 Páginas

  44. AG2Series

    5 Páginas

  45. GST220A

    4 Páginas

  46. GSM40B

    6 Páginas

  47. GSM36B

    4 Páginas

  48. GSC25E

    5 Páginas

  49. TDR-480

    5 Páginas

  50. GC120

    4 Páginas

  51. HDR-30

    5 Páginas

  52. GSM220A

    6 Páginas

  53. EPP-400

    5 Páginas

  54. ENP-120

    5 Páginas

  55. ENC-120

    6 Páginas

  56. ATX-100

    4 Páginas

  57. RPS-200

    7 Páginas

  58. APBR30X75

    2 Páginas

  59. APBR30X60

    2 Páginas

  60. APBR 30X50 MM

    2 Páginas

  61. PSB54/16

    2 Páginas

  62. PSB54/14

    2 Páginas

  63. PSB36T/16

    2 Páginas

  64. PSB35T/12

    2 Páginas

  65. PSB25T/16

    2 Páginas

  66. PSB25T/12

    2 Páginas

  67. PSB21/12

    2 Páginas

  68. PSB 21

    2 Páginas

  69. AD-Series

    16 Páginas

  70. DMU11

    3 Páginas

  71. HDR-30 series

    5 Páginas

  72. DMU30-01

    25 Páginas

  73. DMU30

    3 Páginas

  74. DKA30 serie s

    2 Páginas

  75. DCW12

    2 Páginas

  76. DCW05

    2 Páginas

  77. EH - EF 80 C/P/K

    3 Páginas

  78. 7S Series

    3 Páginas

  79. Model CE36M

    3 Páginas

  80. EX 80 A

    3 Páginas

  81. UFO

    3 Páginas

  82. UFO-M2

    3 Páginas

  83. Dummy DC-Motoren

    2 Páginas

  84. GC30E

    3 Páginas

  85. RPS-400

    11 Páginas

  86. GC 330

    4 Páginas

  87. EL30

    3 Páginas

  88. EA PROFIBUS

    7 Páginas

  89. EAMW

    3 Páginas

  90. AAM58

    4 Páginas

  91. EAM36

    3 Páginas

  92. CARBONOXY25

    2 Páginas

  93. CARBONDIO-%

    2 Páginas

  94. FCX-MC25-CH

    3 Páginas

  95. FCX-MC05-CH

    3 Páginas

  96. FCX-TR0025

    4 Páginas

  97. LP-10HA

    3 Páginas

  98. FCX-UC-CH

    9 Páginas

  99. 901.1-EX

    5 Páginas

  100. FC22

    3 Páginas

  101. MILLINEWTON

    3 Páginas

  102. PFLOW10U-2210

    5 Páginas

  103. 901.1

    5 Páginas

  104. HX-EP

    6 Páginas

  105. VQ548MP & MP-7217

    5 Páginas

  106. Tailor-made

    10 Páginas

  107. RAZTEC

    13 Páginas

  108. The SGX-SureCO

    3 Páginas

  109. 930 Climair

    5 Páginas

  110. Pewatron_Flyer_EN

    8 Páginas