Grupo: Angst+Pfister
Excertos do catálogo

DIGITAL OUTPUT Solid State Pressure SensorCCD Series - Model 54D FEATURES • DIP or SMD Package • Calibrated Span and Offset • Multi-order Temperature compensation • OWI, I2C or SPI Interface • 3V or 5V Supply • Customized Configuration upon request DESCRIPTION The Series CCD Model 54D is a smart pressure transducer with digital output via 1-wire serial, I2C or SPI interface. Digital compensation of sensor offset, sensitivity, temperature drift and nonlinearity is accomplished in factory via an internal DSP running a correction algorithm with calibration coefficients stored in on-chip EEPROM. A variety of characteristic configuration, including accuracy, sampling rate, temperature compensated range are available to provide simple and ready-to-use solution for a wide rage of application. It can be operated in supply voltage of 2.7 to 5.5 V, and can be extended to 30V with an external JFET. The Series CCD is available for pressure range from 0.15 psi to 150 psi. Special configuration as low as 2.5 mbar is also applicable. Please contact factory for detail. Competitive sensor & power supply solutions worldwide PEWATRON
Abrir o catálogo na página 1
Ordering Information Series CCD 54 Digital 54D L XXX G - X 0 X X Option 0: No special reguest Series Supply Voltage Blank = 4.75 to 5.25 V L = 2.75 to 3.33 V Type of Pressure G: Gage (Port B only) H: Gage (Dual Port) A: Absolute (Port A only) D: Differential I: Negative Gage (Port B only) Leading Direction Pressure range Medium Pressure 003 = 0 ~ 3 psi 005 = 0 ~ 5 psi 007 = 0 ~ 7 psi 015 = 0 ~ 15 psi 030 = 0 ~ 30 psi 050 = 0 ~ 50 psi 100 = 0 ~ 100 psi 150 = 0 ~ 150 psi Low Pressure L15 = 0 ~ 0.15 psi L30 = 0 ~ 0.3 psi L50 = 0 ~ 0.5 psi L70 = 0 ~ 0.7 psi Ultra-low Pressure L03 = 0 ~ 2.5...
Abrir o catálogo na página 2
CharacteristicsUnless otherwise specified, all parameters are measured at 3/5V, 25 °C and 60% RH Parameters 1. Supply 3 V or 5 V must be ordered separately. 5. 1.2X for 150 psi 2. Smaller range and other units are also available for ordering 6. Wetted material: PA, RTV, Epoxy, ceramic, Au, nickel and silicon 3. Accuracy includes NOL, hysterisis, TCS and TCO over 0/50°C, BFSL definition 7. Output is ratiometric to supply voltage 4. For differential pressure, offset = 2000 hex, FS = 666/3999 8. Output load resistance to Vss or Vdd: 2.5KQ (min), 10KQ (typ) PORT...
Abrir o catálogo na página 3
CCD54D 1610-21567-0038-E-0913 CharacteristicsUnless otherwise specified, all parameters are measured at 3/5V, 25 °C and 60% RH Parameters 1. Supply 3 V or 5 V must be ordered separately. 5. Over-pressure will vary on different range 2. Smaller range and other units are also available for ordering 6. Wetted material: PA, RTV, Epoxy, ceramic, Au, nickel and silicon 3. Accuracy includes NOL, hysterisis, TCS and TCO over 0/50°C, BFSL definition 8. Output load resistance to Vss or Vdd: 2.5KQ (min), 10KQ (typ) 4. For differential pressure, offset = 2000 hex, FS =...
Abrir o catálogo na página 4
Characteristics Unless otherwise specified, all parameters are measured at 3/5V, 25 °C and 60% RH NOTES: 1. Supply 3V or 5V must be ordered separately. 6. Power up to output 2. Smaller range and other units are also available for ordering 7. Over-pressure will vary on different range 3. Vary with sensor configuration. Refer to individual data sheet. 8. Wetted material: PA, RTV, Epoxy, ceramic, Au, nickel and silicon 4. Accuracy includes N°L, hysterisis, TCS and TCO over 0/50°C, BFSL definition 9. Output load resistance to Vss or Vdd: 2.5KO (min), 10KO (typ) 5. For differential...
Abrir o catálogo na página 5
CharacteristicsUnless otherwise specified, all parameters are measured at 3/5V, 25 °C and 60% RH Parameters 1. Supply 3V or 5V must be ordered separately. 5. Minimum pull-up on SDA and SCL is 1KQ 2. Smaller range and other units are also available for ordering 6. 1.2X for 150 psi 3. Accuracy includes NOL, hysterisis, TCS and TCO over 0/50°C, BFSL definition 7. Wetted material: PA, RTV, Epoxy, ceramic, Au, nickel and silicon 4. For differential pressure, offset = 2000 hex, FS = 666/3999 9. The factory setting for I2C slave address is 0x28 PORT DIFF 1 PORT GAGE 1 PORT ABS NOTE: 1....
Abrir o catálogo na página 6
CharacteristicsUnless otherwise specified, all parameters are measured at 3/5V, 25 °C and 60% RH Parameters 1. Supply 3V or 5V must be ordered separately. 5. Minimum pull-up on SDA and SCL is 1KQ 2. Smaller range and other units are also available for ordering 6. Over-pressure will vary on different range 3. Accuracy includes NOL, hysterisis, TCS and TCO over 0/50°C, BFSL definition 7. Wetted material: PA, RTV, Epoxy, ceramic, Au, nickel and silicon 4. For differential pressure, offset = 2000 hex, FS = 666/3999 8. The factory setting for I2C slave address...
Abrir o catálogo na página 7
CharacteristicsUnless otherwise specified, all parameters are measured at 3/5V, 25 °C and 60% RH Parameters 1. Supply 3V or 5V must be ordered separately. 6. Minimum pull-up on SDA and SCL is 1KQ 2. Custom range and other units are available for ordering 7. Over-pressure may vary from pressure ranges 3. May vary with sensor configuration 8. Wetted material: PA, RTV, Epoxy, ceramic, Au, nickel and silicon 4. Accuracy includes NOL, hysterisis, TCS and TCO over 0/50°C, BFSL definition 9. The factory setting for I2C slave address is 0x28 5. For differential pressure, offset...
Abrir o catálogo na página 8
Communication Interface Manchester codes by a transition at the cell boundary are used to represent the binary values of pressure and temperature. Bit Encoding Data Cell 50% duty cycle used to set up strobe time Read Operation There are two modes (DPT digital pressure output with temperature, and DTO digital pressure out only) available for the output of transducer. For DPO mode, the transducer first transmits the high byte of pressure data followed by the low byte. The pressure data is 14-bits in resolution, so the upper two bits of the high byte are always zero padded. There is a half...
Abrir o catálogo na página 9
Timing The baud rate (transmission frequency) of the Manchester coded bit stream is determined during factory calibration and depends on the update rate and thus response time that the customer specifies for the transducer. If no response time is specified by the customer the default response time of 5ms (200Hz) will be selected. There are a total of 4 different update rates listed below. Using the two faster update rates will result in the baud rate being 32kHz and the two slower update rates will result in the baud rate being set to 8kHz. Hints for Writing Firmware: The Baud rates (8kHz...
Abrir o catálogo na página 10Todos os catálogos e folhetos técnicos Angst+Pfister Sensors and Power AG
-
PAROX 1200 Paramagnetic O2 sensor
4 Páginas
-
SQ-UST_L_0105-01
4 Páginas
-
SQ-UST_L_0104-01
4 Páginas
-
SQ-UST_L_0103-01
4 Páginas
-
SQ-UST_L_0003-01
3 Páginas
-
SQ-UST_L_0002-01
3 Páginas
-
SQ-UST_L_0001-01
3 Páginas
-
PFLOW Series
5 Páginas
-
Model PFLOW3000 Series
16 Páginas
-
LoadSensor StarterKit
3 Páginas
-
Model PFLOW2001 Series
14 Páginas
-
PHPSU 4502 Pressure Transducer
6 Páginas
-
Pewatron PHPSU-4502 vs SCX Series
4 Páginas
-
PSB82_1685-21629-0010-E-1118
3 Páginas
-
V3D-150_1610-21914-0010-E-0620
2 Páginas
-
V3D-070_1610-21914-0009-E-0620
2 Páginas
-
PHPS5600 Pressure Transducer
6 Páginas
-
PHPS-5500_1610-21914-0013-E-0920
7 Páginas
-
PEWA200 Pressure Transmitter
7 Páginas
-
Pewatron PHPSU-4501 vs SCX Series
4 Páginas
-
PHPSU4501 Pressure Transducer
6 Páginas
-
FCX-MC25 & FCX-MC95 OEM module
4 Páginas
-
PZA-MC25-N/P
2 Páginas
-
OXYPA paramagnetic oxygen sensor
4 Páginas
-
PEWA100
9 Páginas
-
HLP-80H series
5 Páginas
-
HLP-40H series
5 Páginas
-
HBG-60P series
6 Páginas
-
UHP-750 series
6 Páginas
-
XLG-50 seri es
9 Páginas
-
DAP-04 series
8 Páginas
-
POB-30 series
11 Páginas
-
RHP-1U Rack System
9 Páginas
-
RFP-M8M4-5A
5 Páginas
-
RFP-M5M3-3A
4 Páginas
-
RFP-M2M3-3A
4 Páginas
-
RFP-M1M3-3A
4 Páginas
-
NCL CL1 01
4 Páginas
-
IRL RGB 01
4 Páginas
-
IRL CL2 01
4 Páginas
-
MSR385WD
3 Páginas
-
MSR145WD
3 Páginas
-
MSR 145
3 Páginas
-
M2029
3 Páginas
-
MSR165
3 Páginas
-
APBL42 Series Brushless DC Motor
2 Páginas
-
CRM102.1
33 Páginas
-
CRM200
39 Páginas
-
CRM100
37 Páginas
-
FPM
4 Páginas
-
FGN
4 Páginas
-
FPN
4 Páginas
-
Pressure Transducer PHPS-3500
6 Páginas
-
PBM220-A14N series
14 Páginas
-
PBM220 series
15 Páginas
-
PBM210-A20K Series
14 Páginas
-
STX Series – Model 13A
11 Páginas
-
CCD Series – Model 53A
7 Páginas
-
APB2Series
5 Páginas
-
AP4Series
5 Páginas
-
AP2Series
5 Páginas
-
PHPS-7500 OEM
6 Páginas
-
PPCP3-M1
10 Páginas
-
AG4Series
6 Páginas
-
AG2Series
5 Páginas
-
New Pewatron brochure
11 Páginas
-
GST220A
4 Páginas
-
GSM40B
6 Páginas
-
GSM36B
4 Páginas
-
GSC25E
5 Páginas
-
TDR-480
5 Páginas
-
GC120
4 Páginas
-
HDR-30
5 Páginas
-
GSM220A
6 Páginas
-
EPP-400
5 Páginas
-
ENP-120
5 Páginas
-
ENC-120
6 Páginas
-
ATX-100
4 Páginas
-
RPS-200
7 Páginas
-
APBR30X75
2 Páginas
-
APBR30X60
2 Páginas
-
APBR 30X50 MM
2 Páginas
-
PSB54/16
2 Páginas
-
PSB54/14
2 Páginas
-
PSB36T/16
2 Páginas
-
PSB35T/12
2 Páginas
-
PSB25T/16
2 Páginas
-
PSB25T/12
2 Páginas
-
PSB21/12
2 Páginas
-
PSB 21
2 Páginas
-
AD-Series
16 Páginas
-
DMU11
3 Páginas
-
HDR-30 series
5 Páginas
-
DMU30-01
25 Páginas
-
DMU30
3 Páginas
-
HPSD 4000 Pressure Transducer 1/7
8 Páginas
-
DKA30 serie s
2 Páginas
-
DCW12
2 Páginas
-
DCW05
2 Páginas
-
EH - EF 80 C/P/K
3 Páginas
-
7S Series
3 Páginas
-
Model CE36M
3 Páginas
-
EX 80 A
3 Páginas
-
STX13A_100-31-410-002-EH-0417
3 Páginas
-
STX13A-D_100-31-410-005-EH-0817
11 Páginas
-
PBM220_100-33-421-003-EH-1216
16 Páginas
-
PBM220-14N_100-33-421-008-EH-0617
14 Páginas
-
PBM220-07N_100-33-421-007-EH-0617
14 Páginas
-
ABS5_100-33-102-001-EH-1016
2 Páginas
-
PHPS-8500_100-31-331-003-EH-0617
12 Páginas
-
FJK-OV_100-31-102-009-EH-1116
2 Páginas
-
100 33 102 012 EH 0315
6 Páginas
-
100 33 102 007 EH 0315
5 Páginas
-
UFO
3 Páginas
-
UFO-M2
3 Páginas
-
ELTRA ABSOLUTE ENCODER OVERVIEW
3 Páginas
-
Dummy DC-Motoren
2 Páginas
-
FCX-MP1000-Extern-FH-CH
3 Páginas
-
GC30E
3 Páginas
-
RPS-400
11 Páginas
-
GC 330
4 Páginas
-
EL30
3 Páginas
-
EA PROFIBUS
7 Páginas
-
EAMW
3 Páginas
-
AAM58
4 Páginas
-
EAM36
3 Páginas
-
ELTRA INCREMENTAL ENCODER OVERVIEW
3 Páginas
-
CARBONOXY25
2 Páginas
-
CARBONDIO-%
2 Páginas
-
FCX-ML25-EXTERN-CH
14 Páginas
-
FCX-MC25-CH
3 Páginas
-
FCX-MC05-CH
3 Páginas
-
FCX-TR0025
4 Páginas
-
A-SeriesOV_100-31-102-011-EH-0317
3 Páginas
-
LP-10HA
3 Páginas
-
FCX-UC-CH
9 Páginas
-
901.1-EX
5 Páginas
-
FC22
3 Páginas
-
MILLINEWTON
3 Páginas
-
PFLOW10U-2210
5 Páginas
-
901.1
5 Páginas
-
HX-EP
6 Páginas
-
VQ548MP & MP-7217
5 Páginas
-
Air quality sensing
6 Páginas
-
Tailor-made
10 Páginas
-
RAZTEC
13 Páginas
-
The SGX-SureCO
3 Páginas
-
930 Climair
5 Páginas
-
984 pressure transmitter
5 Páginas
-
PEM pressure transmitter
5 Páginas
-
Pressure sensor CCD54
4 Páginas
-
MSP-600 600W AC/DC
5 Páginas
-
FCX-MP1000-Extern-FH-CH
3 Páginas
-
Pewatron_Flyer_EN
8 Páginas