Excertos do catálogo

AMETEK PROCESS INSTRUMENTS PRODUCT DATA SHEET 3050-SLR for Super Low Range Moisture Analysis Quartz-crystal microbalance (QCM) technology: accurate, reliable, verifiable and responsive The 3050-SLR provides an extremely accurate measurement of trace levels of moisture in a gas through the use of a quartz-crystal oscillator sample cell. This analyzer brings the benefits of quartz-crystal technology to a broad spectrum of low-range moisture measurement applications. Direct measurement of concentration The 3050-SLR measures moisture concentration directly in parts per million by volume (ppmv), parts per million by weight (ppmw), or mass of water per standard volume without additional pressure or temperature compensation. For customers who wish to convert concentration to dew/frost point, the 3050-SLR can be programmed for a live process pressure input or a fixed process pressure. Accurate and responsive The accuracy of the 3050-SLR is ±0.03 ppmv or ±10% of reading, whichever is greater, over the calibrated range of 0.1 to 100 ppmv. The design of the 3050-SLR enables a speed of response that is far superior to other analyzers, while consuming as little as 150 standard cubic centimeters per minute (sccm) of sample gas. The reliability and stability of the QCM sensor eliminates the need for routine factory recalibration requirements. On-line verification ability The 3050-SLR is equipped with the ability to self-verify its accuracy and sensitivity to moisture. This can be done on a programmed schedule, or whenever necessary. With a built-in zero module and internal moisture generator, the 3050-SLR provides data you will have confidence in. If necessary, the analyzer can make small corrections to its calibration automatically. If a severe calibration problem exists, the analyzer will provide an alarm. ■key benefits • Most accurate trace moisture measurement technology available • Fast response to changing moisture levels • Specific to moisture in most applications • Rugged sensor E APPLICATIONS • The 3050-SLR is specifically designed to monitor trace moisture levels n KEY MARKETS • Petrochemical • Natural gas • Refinery • Chemical
Abrir o catálogo na página 1
3050-SLR for Super Low Range Moisture Analysis AMETEK* PROCESS INSTRUMENTS © 2018, by AMETEK, Inc. All rights reserved. Printed in the U.S.A. F-0126 Rev 10 (0918) One of a family of innovative process analyzer solutions from AMETEK Process Instruments. Specifications subject to change without notice.
Abrir o catálogo na página 2Todos os catálogos e folhetos técnicos AMETEK Process Instruments
-
NATURAL GAS SOLUTIONS
11 Páginas
-
Ranarex Gas Gravitometers
2 Páginas
-
Dew Point Tester
2 Páginas
-
MGB1000 Micro Gas Blender
2 Páginas
-
Dymaxion Mass Spectrometer
4 Páginas
-
LC-D Series Residual Gas Analyzer
2 Páginas
-
ProMaxion Mass Process Spectrometer
2 Páginas
-
Remote Calibration Unit
2 Páginas
-
WDG-VRM Oxygen Analyzer
2 Páginas
-
WDG-VCM Flue Gas Analyzer
2 Páginas
-
TM2000 Oxygen Analyzer
2 Páginas
-
900 Air Demand Analyzer (ADA)
2 Páginas
-
HAG Sampling Probe
2 Páginas
-
5100 CO2 Gas Analyzer Atex
2 Páginas
-
120HD Portable Hydrogen Analyzer
2 Páginas
-
932 Multi Gas Analyzer
2 Páginas
-
919 Hot Wet Gas Analyzer
2 Páginas
-
910 Hot Wet Multi Gas CEM
2 Páginas
-
9900RM/9900WM Gas Analyzers
2 Páginas
-
931 Single Gas Analyzer
2 Páginas
-
933 Hydrogen Sulfide Analyzer
2 Páginas
-
920 Multi Gas Analyzer
2 Páginas
-
909 Hot Wet Single Gas Mass Flow CEM
2 Páginas
-
934 Single-Gas Analyzer
2 Páginas
-
Ranarex Gravitometer
2 Páginas
-
682T-HP Online Sulfur Analyzer
2 Páginas
-
Dew Point Testers
2 Páginas
-
303B Moisture Analyzer
2 Páginas
-
5920 UHP Moisture Analyzer
2 Páginas
-
5910 UHP Moisture Analyzer
2 Páginas
-
5830 Moisture Analyzer
2 Páginas
-
5812 Moisture Analyzer
2 Páginas
-
5800 Moisture Analyzer
2 Páginas
-
2850 Moisture Analyzer
2 Páginas
-
5100 CO2 Gas Analyzer
2 Páginas
-
5100 and 5100HD Gas Analyzers
2 Páginas
-
5000 Sample System
2 Páginas
-
5000 Analyzer Controller
2 Páginas
-
5000 Moisture Analyzer
2 Páginas
-
3050-TE Moisture Analyzer
2 Páginas
-
3050 RM Process Moisture Analyzer
2 Páginas
-
3050-AP Moisture Analyzer
2 Páginas
-
3050-AM Moisture Analyzer
2 Páginas
-
3050-OLV Process Moisture Analyzer
2 Páginas
-
ProLine Process Mass Spectrometer
2 Páginas
-
WDG 1200 1210 Insitu
2 Páginas
-
CEM O2 TM
2 Páginas
-
CEM Humox
2 Páginas
-
WDG-HPII Flue Gas Oxygen Analyzer
2 Páginas
-
TM2000 Trace Oxygen Analyzer
2 Páginas
-
CEM O2 Analyzer
2 Páginas
-
WDG-HPIIC
2 Páginas
-
CG1000
2 Páginas
-
CMFA-P 2000
2 Páginas
-
WDG Insitu Flue Gas Oxygen Analyzer
2 Páginas
-
ta5000 Gas Analyzers
2 Páginas
-
ta3000 Gas Analyzers
2 Páginas