
Excertos do catálogo

EXM Wireless Test Set Datasheet Solve today, evolve tomorrow Agilent EXM Benefits • Optimize multi-device testing with up to four TRX channels per EXM: each is a complete vector signal analyzer/vector signal generator (VSA/VSG) instrument • Easily test multi-format devices with standard-specific X-Series measurement applications • Maximize throughput with raw hardware speed and advanced sequencing • Increase first-pass yield with superior signal purity and measurement accuracy • Get up and running in hours, not days, with validated turnkey chipset solutions In wireless device manufacturing, meeting ever-tougher goals and tighter schedules is easier when you have access to the best resources. The Agilent Technologies EXM wireless test set scales with your production needs and is in sync with the latest cellular and WLAN chipsets. Better yet, it delivers the speed, accuracy, and port density you need to ramp up rapidly and optimize full-volume manufacturing. The EXM is designed for multi-device testing with up to four TRXs: each is a complete vector signal analyzer (VSA), vector signal generator (VSG), and four-port RFIO. It can easily test multi-format cellular and WLAN devices including the latest technologies such as: • LTE-Advanced Carrier Aggregation (CA) • 802.11n/ac Multiple Input Multiple Output (MIMO) • LTE FDD/TDD • TD-SCDMA • HSPA+, W-CDMA • 1xEV-DO, cdma2000® • GSM/EDGE/Evo • 802.11a/b/g/n/ac
Abrir o catálogo na página 1
Agilent Technologies provides the speed, performance, and results you can trust…across the wireless device lifecycle Development Design verication & conformance (RF/RRM/PCT) Ultimate scalability & port density Exceptional value for cellular verication Low-cost WiCon test Industry’s 3G benchmark Industry benchmark GPS LTE-TDD GNSS 802.11ac W-CDMA WLAN HSPA+ HSPA TD-SCDMA EDGE Evo TD-HSPA MIMO Bluetooth® 1x EVDO Speed, performance and results you can trust...Across the wireless device lifecycle
Abrir o catálogo na página 2
Product Features X-Series user interface1 Display port Each TRX has a fully integrated VSA/VSG 1. Technology-specific software. Sold seperately. 2. Included on each TRX module. 4
Abrir o catálogo na página 4
E6640A EXM Applications Cellular Application Flexibility • Consistent repeatability of standard-based X-Series measurement applications • One application license covers up to four TRX units per mainframe • SCPI-controlled PXIe OBT compatible with EXT/E6630A • HSPA+, W-CDMA • GSM/EDGE/EDGE Evo • TD-SCDMA Wireless connectivity • 802.11a/b/g/n/ac • WiMAX • Bluetooth® 1.0 to 4.0 • GNSS: GPS, Galileo, GLONASS, Beidou, SBAS, QZSS • Digital video MIMO (2x2, 3x3, 4x4) and carrier aggregation • Switched MIMO for manufacturing test • True MIMO (multi-TRX) for design validation • LTE-A CA inter- and...
Abrir o catálogo na página 5
Product Specifications Definitions and conditions Specification Specifications describe the performance parameters covered by the product warranty and are valid from 20 to 35 °C unless otherwise noted. Typical Typical describes additional product performance information that is not covered by the product warranty. It is performance beyond specifications that 95 percent of the units exhibit with a 95 percent confidence level. This data, shown in italics, does not include measurement uncertainty, and is valid only at room temperature (approximately 25 °C) after alignment within the stated...
Abrir o catálogo na página 6
Vector signal analyzer performance Performance Capture depth Frequency and time specifications Frequency range All RF ports (options are per TRX module) Option E6640A-504 380 MHz to 3.8 GHz Option E6640A-5WC 1.1 to 1.8 GHz, 2.3 to 2.6 GHz, and 4.8 to 6.0 GHz 380 MHz to 6.0 GHz Option E6640A-506 Specified frequency range (dependent on selected frequency range option) 380 to 495 MHz 695 to 920 MHz 1425 to 1485 MHz 1620 to 2030 MHz 2300 to 2700 MHz 3400 to 3800 MHz 4900 to 6000 MHz Frequency reference Accuracy, aging rate, stability Refer to Timebase Specifications CW measurement frequency...
Abrir o catálogo na página 7
Vector signal analyzer performance continued Amplitude accuracy and range specifications (continued) CW absolute amplitude accuracy RF3 I|O and RF4 I|O ports (configured to input mode in specified frequencies) Frequency range Input level ≤ –8 to –70 dBm 380 to 495 MHz < ±0.60 dB, < ±0.30 dB typical 695 to 730 MHz < ±0.60 dB, < ±0.25 dB typical > 730 to 920 MHz < ±0.50 dB, < ±0.15 dB typical 1425 to 1485 MHz < ±0.65 dB, < ±0.30 dB typical 1620 to 2030 MHz 40 MHz BW < ±0.45 dB, < ±0.20 dB typical 160 MHz BW < ±0.70 dB, < ±0.35 dB typical 2300 to 2700 MHz 40 MHz BW < ±0.55 dB, < ±0.25 dB...
Abrir o catálogo na página 8
Vector signal generator performance Performance Arb bandwidth Arb sample memory (storage capacity) Frequency specifications Frequency range All RF ports (options are per TRX module) 380 MHz to 3.8 GHz Option E6640A-504 1.1 to 1.8 GHz, 2.3 to 2.6 GHz, and 4.8 to 6 GHz Option E6640A-5WC 380 MHz to 6.0 GHz Option E6640A-506 Specified frequency range (dependent on selected frequency range option) 380 to 490 MHz 695 to 960 MHz 1100 to 1325 MHz 1425 to 2180 MHz 2300 to 2700 MHz 3400 to 3800 MHz 4900 to 6000 MHz Frequency reference Accuracy, aging rate, stability Refer to Timebase specifications...
Abrir o catálogo na página 9
Vector signal generator performance continued Amplitude accuracy and range specifications (continued) Absolute level accuracy (specified frequencies, CW) continued 3400 to 3800 MHz Level ≤ +5 to –15 dBm < ±0.60 dB, < ±0.20 dB typical Level ≤ –15 to –80 dBm < ±0.60 dB, < ±0.30 dB typical Level ≤ –80 to –110 dBm < ±1.10 dB, < ±0.55 dB typical 4900 to 6000 MHz Level ≤ +5 to –15 dBm < ±0.70 dB, < ±0.25 dB typical Level ≤ –15 to –80 dBm < ±0.75 dB, < ±0.30 dB typical Level ≤ –80 to –100 dBm < ±1.00 dB, < ±0.50 dB typical Setting resolution 0.01 dB VSWR RF3 I|O and RF4 I|O ports (configured to...
Abrir o catálogo na página 10Todos os catálogos e folhetos técnicos Agilent Technologies - Life Sciences and Chemical
-
Agilent 280 Series AA Systems
12 Páginas
-
Atomic Spectroscopy Innovation
8 Páginas
-
UST and ASTM Petrochemical Standards
40 Páginas
-
Inorganic Standards
40 Páginas
-
Pesticide, PAH, and Lipid Standards
36 Páginas
-
InfinityLab LC Supplies
148 Páginas
-
General Chromatography
164 Páginas
-
Sample Preparation (2018/2019)
144 Páginas
-
MS500
12 Páginas
-
Sensitive and accurate furnace AA
4 Páginas
-
FLAME ATOMIC ABSORPTION SPECTROSCOPY
104 Páginas
-
Agilent training
27 Páginas
-
AGILENT VACUUM PRODUCTS CATALOG
536 Páginas
-
Agilent SD-1 Solvent Delivery Module
4 Páginas
-
Agilent 440 Fraction Collector
4 Páginas
-
Vacuum Measurement Catalog
44 Páginas
-
AGILENT ION Pumps
53 Páginas
-
AGILENT DIFFUSION PUMPS
35 Páginas
-
AGILENT Rotary Vane Pumps
29 Páginas
-
Triple Quadrupole GC/MS PAH Analyzer
2 Páginas
-
Agilent InfinityLab LC Series
16 Páginas
-
Agilent Microplate Centrifuge
4 Páginas
-
3100 fractionator
8 Páginas
-
4200 MP-AES
12 Páginas
-
Solution-ready Agilent 7800 ICP-MS
4 Páginas
-
MOLECULAR SPECTROSCOPY PRODUCTS
4 Páginas
-
Agilent GPC/SEC Solutions
12 Páginas
-
AGILENT ATOMIC ABSORPTION SPECTROMETERS
12 Páginas
-
Agilent?s biomass solutions
12 Páginas
-
Portuguese version - 7900 ICP-MS
8 Páginas
-
Atomic Spectroscopy Portfolio
4 Páginas
-
X-ray Crystallography
12 Páginas
-
Agilent ProPulse NMR System
5 Páginas
-
Agilent Cary 8454 Spectrophotometer
12 Páginas
-
Agilent 4300 Handheld FTIR Spectrometer
12 Páginas
-
An autosampler like no other
4 Páginas
-
Agilent U1450A/U1460A
19 Páginas
-
Agilent B1507A
22 Páginas
-
CXA X-Series Signal Analyzer N9000A
18 Páginas
-
Agilent M9703A
16 Páginas
-
W1905 Radar Model Library
16 Páginas
-
M8048A ISI Channels
7 Páginas
-
Agilent J-BERT M8020A
27 Páginas
-
Agilent N8900 Series
10 Páginas
-
Agilent Protein Identification Solutions
12 Páginas
-
RAPID AND ROBUST EARLY ADME SOLUTIONS
16 Páginas
-
Drugs of Abuse Method Development Guide
12 Páginas
-
I/O Hardware
16 Páginas
-
Advanced Design System
16 Páginas
-
RF & Microwave Attenuators
4 Páginas
-
E4980AL Precision LCR Meter
8 Páginas
-
N9010A EXA X-Series Signal Analyzer
8 Páginas
-
X-Series Measurement Applications
23 Páginas
-
FieldFox Handheld Analyzers
8 Páginas
-
AFM/SPM Accessories
20 Páginas
-
VEE 9.32
24 Páginas
-
M9210A PXI-H 10-bit Digitizing Scope
2 Páginas
-
M9211A PXI-H 10-bit UWB IF Digitizer
2 Páginas
-
B1500A Semiconductor Device Analyzer
16 Páginas
-
89600 VSA Software
9 Páginas
-
Command Expert
2 Páginas
-
N9020A MXA X-Series Signal Analyzer
8 Páginas
-
E5061B Network Analyzer
8 Páginas
-
E5071C ENA Network Analyzers
18 Páginas
-
N9038A MXE EMI Receiver
2 Páginas
-
N9322C Basic Spectrum Analyzer
10 Páginas
-
Digital Multimeters
25 Páginas
-
A0040A Optical Noise Analyzer
2 Páginas
-
M9361A PXI Downconverter
2 Páginas
-
Power Meters and Power Sensors
34 Páginas
-
E7515A UXM Wireless Test Set
2 Páginas
-
Agilent Power Products
31 Páginas
-
E5063A Network Analyzer
8 Páginas
-
N7700A Photonic Application Suite
12 Páginas
-
Leak Detection Catalog
41 Páginas
-
2014 AGILENT CUSTOMER EDUCATION CATALOG
24 Páginas
-
Agilent 7820A GC brochure
8 Páginas
-
8453 UV Dissolution System Brochure
16 Páginas
-
Agilent GC-MSD and QTOF
96 Páginas
-
Capillary Electrophoresis Principle
36 Páginas
-
Agilent GC-MSD 5977
39 Páginas
-
How to Select the Correct GC Column
70 Páginas
-
1290 Infinity Thermostat User Manual
98 Páginas
-
Agilent Intro BERLIN
24 Páginas
-
1290 Infinity Quaternary LC
24 Páginas
-
1260 Infinity Bio-inert
26 Páginas
Catálogos arquivados
-
Diffusion Pumps Catalog
37 Páginas