CB363A
1 / 1Páginas

{{requestButtons}}

Excertos do catálogo

CB363A - 1

Technical features The CB series is a “Switching technology” and “Battery Care philosophy”, since years parts of the core know-how at ADEL system, led to the development of this advanced multi-stage battery charging method, completely automatic and suited to meet the most advanced requirements of battery manufacturers. The Battery Care concept is base on algorithms that implement rapid and automatic charging, battery charge optimization during time, flat batteries recovery and real time diagnostic during installation and operation. The Real Time Autodiagnostic system, monitoring battery faults such as, elements in short circuit, accidental reverse polarity connection, disconnection of the battery, they can easily be detected and removed by help of Blink Code of Diagnosis Led; during the installation and after sell. Each device is suited for all battery types, by means of jumpers it is possible setting predefined curves for Open Lead Acid, Sealed Lead Acid, Gel, NiCd(option). They are programmed for two charging levels, boost and trickle. A rugged casing with bracket for DIN rail mounting provide IP20 protection degree. Input: Single-phase 115  270 Vac Output: Battery charging 36 Vdc; 3 A Suited for the following battery types: Open Lead Acid, Sealed Lead Acid, lead Gel and Ni-Cd (option) Automatic diagnostic of battery status. Charging curve IUoUo, constant voltage and current Switching technology, output voltage 43.2 Vdc Three charging levels: Boost, Trickle, Recovery. Protected against short circuit, inverted polarity, over Load. Signal output (contact free) for fault battery state Protection degree IP20 - DIN rail Frequency Input Current (115 – 230 Vac) Internal Fuse External Fuse (recommended) Battery Output (Battery Care) Boost charge (25 °C) (Typ. at In) Max. time Bust Charge (tpy. At In) Min. time Bust Charge (tpy. At In) Trickle charge (25 °C) (Typ. at In) Jumper Configuration battery type (V cell) Ni-Cd (optional) Recovery Charge Charging. Max Ibatt < 40°C (In) Charging. Max Ibatt > 40°C (In) General Data Insulation voltage (In /Out) Insulation voltage (In / PE) Insulation voltage (Out / PE) Protection Class (EN/IEC 60529) Protection class Reliability: MTBF IEC 61709 Pollution Degree Environment Connection Terminal Blocks screw Type Dimensions (w-h-d) Weight 3000 Vac 1605 Vac 500 Vac IP20 I, with PE connected > 300.000 h 2 2,5mm(24–14AWG) 45x100x100 mm 0.35 Kg approx Climatic Data Ambient temperature (operation) De Rating Ta > 50°C Ambient temperature Storage Humidity at 25 °C no condensation Cooling Norms and Certifications In Conformity to: IEC/EN 60335-2-29 Battery chargers; EN60950 / UL60950-1 and CSA C22.2 No. 60950-1-07 (Information Technology Equipment) – Safety – Part1:General Requirement. Electrical safety; EN54-4 Fire Detection and fire alarm systems; 89/336/EEC EMC Directive; 2014/35/UE (Low Voltage); DIN41773 (Charging cycle); Emission : IEC 61000-6-4; Immunity: IEC 61000-6-2. CE. Signal Output (free switch contact) Main or Backup Power Low Battery Fault Battery Efficiency (50% of In) Charging current limiting Iadj Quiescent Current Charging Curve automatic: IUoUo Detection of element in short circuit Short-circuit protection) Over Load protection Over Voltage Output protection Charging Automatic multi-stage charging and real time diagnostic allow fast recharge and recovery of deep discharged batteries, adding value and reliability to the system hosting. Type of charging it is Voltages and current stabilized IUoUo. The state of charging battery and Autodiagnosis of the systems are identified by a flashing code on a Diagnosis LED and Fault Battery LED: State Diagnosis LED Battery Fault LED Trickle 1 Blink/sec OFF Charging Boost 2 Blink/sec OFF Type Recovery 5 Blink/sec OFF Reverse polarity ON 1Blink Battery No connect ON 2Blink Auto ON diagnosis Element in Short C. 3Blink Replace Battery ON 5Blink Type of Signal Output Contact Max. current can be switched (EN60947.4.1): Max. DC1: 30 Vdc 1 A; AC1: 60 Vac 1A Min.1mA at 5 Vdc Resistive load Min. load Input Data Nominal Input Voltage (2 x Vac) Input Voltage range (Vac) Inrush Current (Vn and In Load) I2t

Abrir o catálogo na página 1

Todos os catálogos e folhetos técnicos ADELSYSTEM

  1. CBI2501224A

    2 Páginas

  2. DFX60110

    1 Páginas

  3. BAT12Wh

    2 Páginas

  4. DFX6024A

    1 Páginas

  5. DFX6012A

    1 Páginas

  6. DFX1512A

    1 Páginas

  7. DFX1524A

    1 Páginas

  8. CBI6024A

    1 Páginas

  9. CBI6012A

    1 Páginas

  10. CB6024A

    1 Páginas

  11. CB6012A

    1 Páginas

  12. FLEX50048A

    1 Páginas

  13. FLEX28048A

    1 Páginas

  14. FLEX17048A

    1 Páginas

  15. FLEX28012A

    1 Páginas

  16. FLEX17012A

    1 Páginas

  17. FLEX6012A

    1 Páginas

  18. FLEX28024B

    1 Páginas

  19. FLEX50024B

    1 Páginas

  20. FLEX17024B

    1 Páginas

  21. FLEX9024B

    1 Páginas

  22. FLEX50024A

    1 Páginas

  23. FLEX28024A

    1 Páginas

  24. FLEX17024A

    1 Páginas

  25. FLEX9024A

    1 Páginas

  26. FLEX6024A

    1 Páginas

  27. DPY353

    1 Páginas

  28. DPY351

    2 Páginas

  29. MRF102

    1 Páginas

  30. DC-UPS Catalogue

    12 Páginas

  31. CB2420A

    1 Páginas

  32. CB2410AC

    1 Páginas

  33. CB1235A

    1 Páginas

  34. CB243A

    1 Páginas

  35. CB304A

    1 Páginas

  36. CB123A/48

    1 Páginas

  37. CB1210A

    1 Páginas

  38. CB123A

    1 Páginas

  39. CB122410A

    1 Páginas

  40. CB12245AJ

    1 Páginas

  41. CB12245A

    1 Páginas

  42. BAT12VRLA

    1 Páginas

  43. BAT7.2VRLA

    1 Páginas

  44. BAT3.4VRLA

    1 Páginas

  45. BAT1.2VRLA

    1 Páginas

  46. CBI2801224A

    2 Páginas

  47. CBI4810A

    1 Páginas

  48. CBI2420AP

    1 Páginas

  49. CBI2420A

    1 Páginas

  50. CBI1235A

    1 Páginas

  51. CBI485A

    1 Páginas

  52. CBI2410A

    1 Páginas

  53. CBI245A

    1 Páginas

  54. CBI243A

    1 Páginas

  55. CBI1210A

    1 Páginas

  56. CBI126A

    1 Páginas

  57. CBI123A

    1 Páginas