Automatic control units, OMD200 and OMD300
1 / 48Páginas

{{requestButtons}}

Excertos do catálogo

Automatic control units, OMD200 and OMD300 - 1

Automatic control units, OMD200 and 300 Installation and operating instructions Power and productivity

Abrir o catálogo na página 1
Automatic control units, OMD200 and OMD300 - 3

Installation and operating instructions, OMD200 and OMD300

Abrir o catálogo na página 3
Automatic control units, OMD200 and OMD300 - 4

Installation and operating instructions, OMD200 and OMD300

Abrir o catálogo na página 4
Automatic control units, OMD200 and OMD300 - 5

Installation and operating instructions, OMD200 and OMD300 1. Introduction This manual describes the installation and the basic operation of the OMD200 and OMD300 automatic control units. The instructive part is followed by a section on available accessories. 1.1 Use of symbols Hazardous voltage: warns about a situation where a hazardous voltage may cause physical injury to a person or damage to equipment. General warning: warns about a situation where something other than electrical equipment may cause physical injury to a person or damage to equipment. Caution: provides important...

Abrir o catálogo na página 5
Automatic control units, OMD200 and OMD300 - 6

Installation and operating instructions, OMD200 and OMD300 2. Product overview The automatic transfer switch concept is applied to any application requiring switching from the primary power line to secondary power line to ensure the supply of loads. OMD200: Analysing the voltage, frequency and the phase balance. Includes the generator START / STOP command. OMD200 has two sensors to monitor two three-phase power lines, both able to work with single phase, too. It has the capability to monitor two power supply lines and to manage a single change-over switch. With DIP-switches it can be chosen...

Abrir o catálogo na página 6
Automatic control units, OMD200 and OMD300 - 7

Installation and operating instructions, OMD200 and OMD300 2.1 Typical applications A. Mains - Generator line In case of loss of the primary power line, the OMD_ device manages the switching to the emergency power line equipped with a genset system. Mains - Generator line B. Mains a – Mains b In case of loss of the primary power line, the OMD_ device manages the switching to a secondary power line used as an emergency source. Automatic control unit type OMD_ is designed for single and three-phase distribution systems in diverse applications. OMD_ is supplied from Line 1 and Line 2 and can...

Abrir o catálogo na página 7
Automatic control units, OMD200 and OMD300 - 8

Installation and operating instructions, OMD200 and OMD300 Automatic control units OMD_ have the capability to monitor two three-phase power lines, both able to also work with single phase. With DIP switches, it can be chosen whether or not the N-line is connected. If OMD_ is used without the N-line, the external transformer must be used. LINE 1 L1 L2 L3 1 L1 2 L2 X11 LN1 3 L3 4 If OMD_ is used without the N-line, the external transformer must be used.

Abrir o catálogo na página 8
Automatic control units, OMD200 and OMD300 - 9

Installation and operating instructions, OMD200 and OMD300 3. Description 3.1 OMD200 and OMD300 switching sequence 3.1.1 Line 1 priority The switching sequence can be summarized in following steps: An anomaly occurs on the Line 1 Switching delay Generator start Change-over switch (Switch I) to the position O Change-over switch (Switch II) to the position II And the back switching sequence can be summarized in the following steps: The Line 1 will start the normal functioning Back switching delay Change-over switch (Switch II) to the position O Change-over switch (Switch I) to the position I...

Abrir o catálogo na página 9
Automatic control units, OMD200 and OMD300 - 10

Installation and operating instructions, OMD200 and OMD300 3.1.2 No line priority The switching sequence can be summarized in following steps: An anomaly occurs on the Line 1 Switching delay Generator start Change-over switch (Switch I) to the position O Change-over switch (Switch II) to the position II And the back switching sequence can be summarized in the following steps: The Line 1 will start the normal functioning Change-over switch stays in position II An anomaly occurs on the Line 2 Back switching delay Change-over switch (Switch II) to the position O Change-over switch (Switch I)...

Abrir o catálogo na página 10
Automatic control units, OMD200 and OMD300 - 11

3. Description Installation and operating instructions, OMD200 and OMD300 3.1.3 Manual back switching mode The switching sequence of OMD200 and OMD300 can be summarized in following steps: ► An anomaly occurs on the Line 1 ► Switching delay ► Change-over switch (Switch I) to the position O ► Change-over switch (Switch II) to the position II And the back switching sequence can be summarized in the following steps: ► The Line 1 will start the normal functioning ► Change-over switch stays in position II ► An anomaly occurs on the Line 2 ► Back switching delay ► Change-over switch (Switch...

Abrir o catálogo na página 11
Automatic control units, OMD200 and OMD300 - 12

Installation and operating instructions, OMD200 and OMD300 4. Installation 4.1 Dimensional drawings 96

Abrir o catálogo na página 12
Automatic control units, OMD200 and OMD300 - 13

Installation and operating instructions, OMD200 and OMD300 4.2 Mounting 4.2.1 Door mounting The automatic control unit OMD_ can be mounted on the door with the fastener OMZD1, see Accessories, Section 10. Door drilling according to Figure 4.2. As an optional extra you can use the cover plate OMZC2 on the door for OMD200 and 300, see Figure 4.3 on next page and Accessories, Section 10. Automatic control unit OMD_, door mounting, door drilling

Abrir o catálogo na página 13
Automatic control units, OMD200 and OMD300 - 14

Installation and operating instructions, OMD200 and OMD300 Automatic control unit OMD200 and 300, door mounting with the cover plate, door drilling for the cover plate OMZC2, see Accessories, Section 10

Abrir o catálogo na página 14
Automatic control units, OMD200 and OMD300 - 15

Installation and operating instructions, OMD200 and OMD300 4.2.3 DIN-rail mounting The automatic control unit OMD_ can be mounted on the 35 mm DIN-rail, see the Figure 4.4. Door drilling, if needed, according to Figure 4.4. As an optional extra you can use the cover plate OMZC2 on the door for OMD200 and OMD300, see Figure 4.5 and Accessories, Section 10. Automatic control unit OMD_, DIN-rail mounting, door drilling 15 1SCC390125M0203, rev. C

Abrir o catálogo na página 15
Automatic control units, OMD200 and OMD300 - 16

Installation and operating instructions, OMD200 and OMD300 Automatic control unit OMD_, DIN-rail mounting with the cover plate, door drilling for the cover plate OMZC2, see Accessories, Section 10

Abrir o catálogo na página 16
Automatic control units, OMD200 and OMD300 - 17

5. Connecting Installation and operating instructions, OMD200 and OMD300 Only an authorised electrician may perform the electrical installation and maintenance of automatic transfer switches. Do not attempt any installation or maintenance actions when an automatic transfer switch is connected to the electrical mains. Before starting work, make sure that the switch is de-energised. 5.1 Power circuit Operating voltage: Main voltage: 208Vac - 480Vac (±20%) Phase setting with DIP switches: Single phase or Three-phase (default). OMD200: If the automatic control unit OMD200 is used without...

Abrir o catálogo na página 17

Todos os catálogos e folhetos técnicos ABB Smart Power

  1. Bus couplers

    3 Páginas

  2. SlimLine XR

    52 Páginas

  3. SACE Emax 2

    277 Páginas

  4. TruOne

    68 Páginas

  5. Switch-disconnectors

    192 Páginas

  6. OFAM/ OFAA

    2 Páginas

  7. SACE Tmax XT

    8 Páginas

  8. YO-YC Test unit

    5 Páginas

  9. Pacific Intertie

    2 Páginas

  10. ABB Division

    17 Páginas

  11. ABB HVDC Classic

    24 Páginas

  12. V400

    2 Páginas

  13. V16

    2 Páginas

  14. P42E

    2 Páginas

  15. Nightstar

    2 Páginas

  16. ROYCE THOMPSON

    4 Páginas

  17. EasyLine XLP

    31 Páginas