Data Sheet DS/TTR200-EN Rail mounted Temperature Transmitter TTR200 HART, Pt100 (RTD), thermocouples, Electrical isolation Input - Resistance thermometer - Thermocouples - Resistance-type transmitters - Voltages, mV voltages Output - 4 ... 20 mA, HART Measurement deviation - 0.1 K Sensor error adjustment Continuous sensor monitoring and selfmonitoring - Two function LEDs - Supply voltage monitoring - Wire break and corrosion monitoring in accordance with NE 89 Device safety in accordance with NE 53 SIL2 acc. to IEC 61508 Approvals for explosion protection - ATEX, IECEx, Zone 0 - FM / CSA Configuration - DTM - EDD Contents
Abrir o catálogo na página 1
Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 3 1 Specifications Change from one to two columns 1.1 Input 1.1.1 Resistance thermometers/Resistors Resistance thermometer Pt100 in accordance with IEC 60751, JIS C1604-81, MIL-T- 24388, Ni in accordance with DIN 43760, Cu Resistance measurement 0 … 500 Ù 0 … 5000 Ù Sensor connection type Two-, three-, four-wire circuit Connecting cable Maximum sensor line resistance (RW) for each line 50 Ù according to NE 89 (January 2009) Three-wire circuit: symmetrical sensor line resistances...
Abrir o catálogo na página 3
Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 4 2 General information Change from one to two columns CE Marking The TTR200 meets all requirements for the CE mark in accordance with IEC 61326 (2006) Electrical isolation 3.5 kV DC (approx. 2.5 kV AC) 60 s, input to output MTBF time 28 years at 60 °C ambient temperature Input filter 50 / 60 Hz Switch-on delay < 10 s (Ia 3.6 mA during starting cycle) Warm-up time 5 minutes Ramp-up time t90 400 … 1000 ms Rate updated 10/s, independent of sensor type and sensor circuit Output...
Abrir o catálogo na página 4
Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 5 Change from one to two columns 2.6 Measuring accuracy Includes linearity deviation, reproducibility/hysteresis at 23 °C (73.4 °F) ± 5 K and 20 V supply voltage Information on measuring accuracy corresponds to 3 ó (Gaussian distribution) Input element Standard Sensor Measuring range limits Minimum span Digital measuring accuracy (24-bit A/D converter) D/A measuring accuracy 1) (16-bit DA) Resistance thermometer/resistor IEC 60 751 Pt10 Pt50 Pt100 Pt200 Pt500 Pt1000 (a=0,003850)...
Abrir o catálogo na página 5
Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 6 2.7 Operating influences The percentages refer to the configured measuring span. Supply voltage influence/load influence: within the specified limits for the voltage/load, the total influence is less than 0.001 % per volt Common-mode interference: no influence up to 100 Veff (50 Hz) or 50 V DC Ambient temperature influence: based on 23 °C (73.4 °F) for ambient temperature range -40 ... 85 °C (-40 ... 185 °F) Sensor Influence of ambient temperature per 1 °C (1.8 °F) deviation to...
Abrir o catálogo na página 6
Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 7 Kommunikation 3 Communication Change from one to two columns 3.1 Configuration parameters Measurement type Sensor type, connection type Error signaling Measurement range General information, e.g., TAG number Damping Signal simulation of output For additional information, see Section 8, "Order form configuration" Write protection Software write protection Diagnostic information in accordance with NE 107 Sensor error (wire break or short circuit) Device error Over/under alarm...
Abrir o catálogo na página 7
Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 8 4 Electrical connections Fehler! Verweisquelle konnte nicht gefunden werden. A00203 12 ... 30 / 42 V DC + 11 - 4 ... 20 mA TTR200 + 11 PWR ERR OFF ON 1 2 - 1 2 3 4 5 6 A 4 2 2 2 1 1 1 1 1 1 4 3 3 3 3 3 3 2 1 2 3 4 5 6 + - 7 2 3 + - 8 9 2 3 Fig. 3 1 Potentiometer, four-wire circuit 2 Potentiometer, three-wire circuit 3 Potentiometer, two-wire circuit 4 RTD, four-wire circuit 5 RTD, three-wire circuit 6 RTD, two-wire circuit 7 Voltage measurement 8 Thermocouple 9 Terminal 11:...
Abrir o catálogo na página 8
Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 9 Bestellangaben 6 Ordering information Main order number Add. order no. Version number 1 - 6 7 8 9 10 11 XX TTR200 rail-mounted temperature transmitter, HART, Pt100 (RTD), thermocouples, electrical isolation TTR200 X X X X X XX Explosion protection Without explosion protection Y 0 ATEX intrinsic safety type of protection: Zone 0: II 1 G Ex ia IIC T6, zone 1 (0): II 2 (1) G Ex [ia] ib IIC T6, Zone 1 (20): II 2 G (1D) Ex [iaD] ib IIC T6 E 1 ATEX non-sparking type of protection:...
Abrir o catálogo na página 9
Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 10 7 Ex relevant specifications Change from one to two columns The TTR200 complies with the requirements of ATEX Directive 94/9/EC. 7.1 TTR200-E1, Intrinsic Safety ATEX Explosion protection Approved for use in Zone 0 and 1 Designation II 1G Ex ia IIC T6 (Zone 0) II 2(1)G Ex [ia] ib IIC T6 (Zone 1 [0]) II 2G(1D) Ex [iaD] ib IIC T6 (Zone 1 [20]) EC type-examination test certificate PTB 05 ATEX 2017 X 7.2 TTR200-H1, Intrinsic Safety IECEx Designation Ex ia IIC T6 Ex [ia] ib IIC T6 Ex...
Abrir o catálogo na página 10
ABB has Sales & Customer Support expertise in over 100 countries worldwide. www.abb.com/temperature The Company’s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in the Fed. Rep. of Germany (04.2010) © ABB 2010 3KXT241001R1001 DS/TTR200-EN Rev. B ABB Limited Salterbeck Trading Estate Workington, Cumbria CA14 5DS UK Tel: +44 (0)1946 830 611 Fax: +44 (0)1946 832 661 ABB Inc. 125 E. County Line Road Warminster, PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 ABB Automation Products GmbH...
Abrir o catálogo na página 12Todos os catálogos e folhetos técnicos ABB Measurement & Analytics
-
FSM4000 Electromagnetic Flowmeter
72 Páginas
-
Sensyflow FMT700-P Compact
4 Páginas
-
CoriolisMaster FCB100, FCH100
60 Páginas
-
ProKiln GAC400
24 Páginas
-
Open up a new world of water analysis
12 Páginas
-
AV1 and AV2
24 Páginas
-
LP Linear pneumatic piston actuator
28 Páginas
-
OriMaster FPD500
24 Páginas
-
AquaProbe FEA200
16 Páginas
-
FTPA2000-HP260
4 Páginas
-
TSM800 Multipoint temperature sensor
8 Páginas
-
266HSH and 266NSH
40 Páginas
-
261GC, 261GG, 261GN and 261AC
44 Páginas
-
LM200 Laser level transmitter
24 Páginas
-
LLT100 Laser level transmitter
26 Páginas
-
FPD350 Torbar Averaging pitot tubes
56 Páginas
-
CoriolisMaster FCB400, FCH400
104 Páginas
-
PME120-AI / PME120-AN (Contrac)
28 Páginas
-
TX - Thermal dispersion switch
5 Páginas
-
Millmate roll force systems
20 Páginas
-
FTSW100 Process software
4 Páginas
-
Totalflow host software
8 Páginas
-
SCK
20 Páginas
-
Plunger Analysis Software (PAS)
4 Páginas
-
SCADAvantage™ EFM Tool
4 Páginas
-
INDI-BOY DSP
8 Páginas
-
CRANE-BOY / CRANE-BOYP
8 Páginas
-
9QGPS5100L Tension load cell
12 Páginas
-
9QGPS4500
8 Páginas
-
9QGPS3100P
12 Páginas
-
9QGPS2960
12 Páginas
-
9QGPS2625
8 Páginas
-
Ultrasonic level LST400
12 Páginas
-
MB3600-HP10
5 Páginas
-
MB3600-CH10
8 Páginas
-
ACF5000
16 Páginas
-
Diode laser analyser LS4000
4 Páginas
-
Magnos28
10 Páginas
-
Dynamic QR Code
4 Páginas
-
EL3060
8 Páginas
-
Pressductor Radial load cells
20 Páginas
-
HP30
4 Páginas
-
Aztec ATS430
12 Páginas
-
LMS200
12 Páginas
-
PGC5000
8 Páginas
-
LGR-ICOS 927S
4 Páginas
-
Recording and Control
20 Páginas
-
2600T Pressure Transmitters
12 Páginas
-
TZIDC and TZIDC-200
8 Páginas
-
ProcessMaster FEP610
8 Páginas
-
ALSCAN Brochure
6 Páginas
-
MR Series
2 Páginas
-
Emission Monitoring
8 Páginas
-
Variable Area Flowmeters - VA Master
12 Páginas
-
Compact Orifice Flow Meter OriMaster
12 Páginas
-
Thermal Mass Flowmeter Sensyflow
8 Páginas
-
Turbidity Systems 4670 Series
16 Páginas
-
Sodium Monitor Model 8036
8 Páginas
-
Residual Chlorine Monitor AW400
8 Páginas
-
Aztec 600 Iron Analyzer
12 Páginas
-
First for Liquid Analysis
16 Páginas
-
Aluminium Analyzer Aztec 600 Aluminium
12 Páginas
-
ABB product catalog
32 Páginas
-
process photometer
6 Páginas
-
Mass Flowmeter CoriolisMaster
8 Páginas
-
Sodium Monitor Model 8036
8 Páginas
-
PH/Redox (ORP) Sensor for Critical Processes
16 Páginas